-
1
-
-
0031079674
-
Effect of long‐term topical betaxolol on tissue circulation in the iris and optic nerve head
-
1 Araie M, Muta K: Effect of long‐term topical betaxolol on tissue circulation in the iris and optic nerve head. Exp Eye Res 64: 167–172, 1997
-
(1997)
Exp Eye Res
, vol.64
, pp. 167-172
-
-
Araie, M1
Muta, K2
-
2
-
-
0019579052
-
Flow visualization by means of single‐exposure speckle photography
-
2 Fercher AF, Briers JD: Flow visualization by means of single‐exposure speckle photography. Optics Comm 37: 326–330, 1981
-
(1981)
Optics Comm
, vol.37
, pp. 326-330
-
-
Fercher, AF1
Briers, JD2
-
3
-
-
0000646850
-
Evaluation of blood flow by laser speckle image sensing. Part 1
-
3 Fujii H, Nohira K, Yamamoto Y, Ikawa H, Ohura T: Evaluation of blood flow by laser speckle image sensing. Part 1. Appl Opt 26: 5321–5325, 1987
-
(1987)
Appl Opt
, vol.26
, pp. 5321-5325
-
-
Fujii, H1
Nohira, K2
Yamamoto, Y3
Ikawa, H4
Ohura, T5
-
4
-
-
0028166592
-
Visulisation of retinal blood flow by laser speckle flow‐graphy
-
4 Fujii H: Visulisation of retinal blood flow by laser speckle flow‐graphy. Med Biol Eng Comput 32: 302–304, 1994
-
(1994)
Med Biol Eng Comput
, vol.32
, pp. 302-304
-
-
Fujii, H1
-
5
-
-
0025050573
-
Laser Doppler flowmetry and bone blood flow in an isolated perfused preparation
-
5 Handley RC, Essex T, Pooley J: Laser Doppler flowmetry and bone blood flow in an isolated perfused preparation. J Med Eng Technol 14: 201–204, 1990
-
(1990)
J Med Eng Technol
, vol.14
, pp. 201-204
-
-
Handley, RC1
Essex, T2
Pooley, J3
-
6
-
-
0020957086
-
Measurement of microvascular blood flow in cancellous bone using laser Doppler flowmetry and 133Xe‐clearance
-
6 Hellem S, Jacobsson LS, Nilsson GE, Lewis DH: Measurement of microvascular blood flow in cancellous bone using laser Doppler flowmetry and 133 Xe‐clearance. Int J Oral Surg 12: 165–177, 1983
-
(1983)
Int J Oral Surg
, vol.12
, pp. 165-177
-
-
Hellem, S1
Jacobsson, LS2
Nilsson, GE3
Lewis, DH4
-
7
-
-
0027626750
-
Laser Doppler flowmetry for estimation of bone blood flow: studies of reproducibility and correlation with microsphere technique
-
7 Lausten GS, Kiaer T, Dahl B: Laser Doppler flowmetry for estimation of bone blood flow: studies of reproducibility and correlation with microsphere technique. J Orthop Res 11: 573–580, 1993
-
(1993)
J Orthop Res
, vol.11
, pp. 573-580
-
-
Lausten, GS1
Kiaer, T2
Dahl, B3
-
9
-
-
0026452598
-
Acute effect of traction, compression, and hip joint tamponade on blood flow of the femoral head: an experimental model
-
9 Naito M, Schoenecker PL, Owen JH, Sugioka Y: Acute effect of traction, compression, and hip joint tamponade on blood flow of the femoral head: an experimental model. J Orthop Res 10: 800–806, 1992
-
(1992)
J Orthop Res
, vol.10
, pp. 800-806
-
-
Naito, M1
Schoenecker, PL2
Owen, JH3
Sugioka, Y4
-
10
-
-
0005510508
-
Simultaneous bone blood flow measurements in dogs utilizing radioactive tracer microspheres and hydrogen washout
-
10 Niv AI, Hungerford DS, Jones LC: Simultaneous bone blood flow measurements in dogs utilizing radioactive tracer microspheres and hydrogen washout. Trans Orthop Res Soc 5: 156, 1980
-
(1980)
Trans Orthop Res Soc
, vol.5
, pp. 156
-
-
Niv, AI1
Hungerford, DS2
Jones, LC3
-
11
-
-
0024671914
-
Laser Doppler flowmetry for bone blood flow measurements: helium‐neon laser light attenuation and depth of perfusion assessment
-
11 Nötzli HP, Swiontkowski MF, Thaxter ST, Carpenter, GK III, Wyatt R: Laser Doppler flowmetry for bone blood flow measurements: helium‐neon laser light attenuation and depth of perfusion assessment. J Orthop Res 7: 413–424, 1989
-
(1989)
J Orthop Res
, vol.7
, pp. 413-424
-
-
Nötzli, HP1
Swiontkowski, MF2
Thaxter, ST3
Carpenter, GK4
Wyatt, R5
-
12
-
-
0025380989
-
Blood flow determination by the laser speckle method
-
12 Ruth B: Blood flow determination by the laser speckle method. Int J Microcirc Clin Exp 9: 21–45, 1990
-
(1990)
Int J Microcirc Clin Exp
, vol.9
, pp. 21-45
-
-
Ruth, B1
-
13
-
-
0028397638
-
Measuring the steady‐state value and the dynamics of the skin blood flow using the non‐contact laser speckle method
-
13 Ruth B: Measuring the steady‐state value and the dynamics of the skin blood flow using the non‐contact laser speckle method. Med Eng Phys 16: 105–111, 1994
-
(1994)
Med Eng Phys
, vol.16
, pp. 105-111
-
-
Ruth, B1
-
14
-
-
0007689291
-
Clinical assessment of nonunion vascularity using laser Doppler flowmetry
-
14 Sanders RW, Swiontkowski MF, Schlehr FJ: Clinical assessment of nonunion vascularity using laser Doppler flowmetry. Orthop Trans 11: 464–465, 1987
-
(1987)
Orthop Trans
, vol.11
, pp. 464-465
-
-
Sanders, RW1
Swiontkowski, MF2
Schlehr, FJ3
-
15
-
-
0018023325
-
The acute effect of position of immobilization on capital femoral epiphyseal blood flow: a quantitative study using the hydrogen washout technique
-
15 Schoenecker PL, Bitz M, Whiteside LA: The acute effect of position of immobilization on capital femoral epiphyseal blood flow: a quantitative study using the hydrogen washout technique. J Bone Joint Surg [Am] 60: 899–904, 1978
-
(1978)
J Bone Joint Surg [Am]
, vol.60
, pp. 899-904
-
-
Schoenecker, PL1
Bitz, M2
Whiteside, LA3
-
16
-
-
0025823722
-
Laser Doppler bone probe: an experimental study in dogs
-
16 Schuurman AH, Bos KE: Laser Doppler bone probe: an experimental study in dogs. Microsurgery 12: 246–251, 1991
-
(1991)
Microsurgery
, vol.12
, pp. 246-251
-
-
Schuurman, AH1
Bos, KE2
-
17
-
-
0030012569
-
[Comparative measurement of optic nerve head circulation using laser speckle circulation analyser of ocular fundus and a hydrogen clearance method
-
17 Sugiyama T, Toda M, Kojima S, Utsumi T, Azuma I: [Comparative measurement of optic nerve head circulation using laser speckle circulation analyser of ocular fundus and a hydrogen clearance method.] Nippon Ganka Gakkai Zasshi 100: 443–447, 1996
-
(1996)
Nippon Ganka Gakkai Zasshi
, vol.100
, pp. 443-447
-
-
Sugiyama, T1
Toda, M2
Kojima, S3
Utsumi, T4
Azuma, I5
-
18
-
-
0023036459
-
Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow
-
18 Swiontkowski MF, Tepic S, Perren SM, Moor R, Ganz R, Rahn BA: Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow. J Orthop Res 4: 362–371, 1986
-
(1986)
J Orthop Res
, vol.4
, pp. 362-371
-
-
Swiontkowski, MF1
Tepic, S2
Perren, SM3
Moor, R4
Ganz, R5
Rahn, BA6
-
19
-
-
0023230987
-
Laser Doppler flowmetry for clinical evaluation of femoral head necrosis: preliminary experience
-
19 Swiontkowski MF, Ganz R, Schlegel U, Perren SM: Laser Doppler flowmetry for clinical evaluation of femoral head necrosis: preliminary experience. Clin Orthop 218: 181–185, 1987
-
(1987)
Clin Orthop
, vol.218
, pp. 181-185
-
-
Swiontkowski, MF1
Ganz, R2
Schlegel, U3
Perren, SM4
-
20
-
-
0028148886
-
Noncontact, two‐dimensional measurement of retinal microcirculation using laser speckle phenomenon
-
20 Tamaki Y, Araie M, Kawamoto E, Eguchi S, Fujii H: Noncontact, two‐dimensional measurement of retinal microcirculation using laser speckle phenomenon. Invest Ophthalmol Vis Sci 35: 3825–3834, 1994
-
(1994)
Invest Ophthalmol Vis Sci
, vol.35
, pp. 3825-3834
-
-
Tamaki, Y1
Araie, M2
Kawamoto, E3
Eguchi, S4
Fujii, H5
-
21
-
-
0028951869
-
Non‐contact, two‐dimensional measurement of tissue circulation in choroid and optic nerve head using laser speckle phenomenon
-
21 Tamaki Y, Araie M, Kawamoto E, Eguchi S, Fujii H: Non‐contact, two‐dimensional measurement of tissue circulation in choroid and optic nerve head using laser speckle phenomenon. Exp Eye Res 60: 373–383, 1995
-
(1995)
Exp Eye Res
, vol.60
, pp. 373-383
-
-
Tamaki, Y1
Araie, M2
Kawamoto, E3
Eguchi, S4
Fujii, H5
-
22
-
-
0029929976
-
Time change of nicardipine effect on choroidal circulation in rabbit eyes
-
22 Tamaki Y, Araie M, Tomita K, Tomidokoro A: Time change of nicardipine effect on choroidal circulation in rabbit eyes. Curr Eye Res 15: 543–548, 1996
-
(1996)
Curr Eye Res
, vol.15
, pp. 543-548
-
-
Tamaki, Y1
Araie, M2
Tomita, K3
Tomidokoro, A4
-
23
-
-
0031890229
-
In vivo measurement of iridial circulation using laser speckle phenomenon
-
23 Tomidokoro A, Araie M, Tamaki Y, Tomita K: In vivo measurement of iridial circulation using laser speckle phenomenon. Invest Ophthalmol Vis Sci 39: 364–371, 1998
-
(1998)
Invest Ophthalmol Vis Sci
, vol.39
, pp. 364-371
-
-
Tomidokoro, A1
Araie, M2
Tamaki, Y3
Tomita, K4
-
24
-
-
0017429856
-
Measurement of regional bone and bone marrow blood flow in the rabbit using the hydrogen washout technique
-
24 Whiteside LA, Lesker PA, Simmons DJ: Measurement of regional bone and bone marrow blood flow in the rabbit using the hydrogen washout technique. Clin Orthop 122: 340–346, 1977
-
(1977)
Clin Orthop
, vol.122
, pp. 340-346
-
-
Whiteside, LA1
Lesker, PA2
Simmons, DJ3
|