1
-
-
0014108190
-
Phacoemulsification and aspiration: A new technique of cataract removal, a preliminary report
-
1 Kelman CD: Phacoemulsification and aspiration: a new technique of cataract removal, a preliminary report. Am J Ophthalmolol 1967, 64:23-35.
-
(1967)
Am J Ophthalmolol
, vol.64
, pp. 23-35
-
-
Kelman, C.D.1
-
2
-
-
0029922137
-
Temperature measurements during phacoemulsification and erbium: YAG laser phacoablation in model systems
-
2 Berger JW, Talamo JH, LaMarche KJ, et al.: Temperature measurements during phacoemulsification and erbium: YAG laser phacoablation in model systems. J Cataract Refract Surg 1996, 22:372-378.
-
(1996)
J Cataract Refract Surg
, vol.22
, pp. 372-378
-
-
Berger, J.W.1
Talamo, J.H.2
LaMarche, K.J.3
-
3
-
-
2642619405
-
Erbium:YAG laser-assisted cataracts surgery
-
The authors conducted a prospective nonrandomized case series using the Er:YAG laser for cataract removal in 15 patients. Complete removal of the cataract with the laser alone was possible in nine eyes. A conversion to ultrasonic phacoemulsification was utilized in six eyes. No laser-related complications were noted during a follow-up period of 6 weeks. This is the first published series of patients undergoing Er:YAG laser-assisted cataract surgery
-
3 Stevens G, Jr, Long B, Hamann JM, Allen RC: Erbium:YAG laser-assisted cataracts surgery. Ophthalmic Surg Lasers 1998, 29:185-189. The authors conducted a prospective nonrandomized case series using the Er:YAG laser for cataract removal in 15 patients. Complete removal of the cataract with the laser alone was possible in nine eyes. A conversion to ultrasonic phacoemulsification was utilized in six eyes. No laser-related complications were noted during a follow-up period of 6 weeks. This is the first published series of patients undergoing Er:YAG laser-assisted cataract surgery.
-
(1998)
Ophthalmic Surg Lasers
, vol.29
, pp. 185-189
-
-
Stevens G., Jr.1
Long, B.2
Hamann, J.M.3
Allen, R.C.4
-
4
-
-
0346095086
-
In vitro comparison of phacoemulsifcation and the erbium:YAG laser in lens capsule rupture
-
4 Snyder RW, Noecker RJ, Jones H: In vitro comparison of phacoemulsifcation and the erbium:YAG laser in lens capsule rupture. Invest Ophthalmol Vis Sci 1994, 35:4.
-
(1994)
Invest Ophthalmol Vis Sci
, vol.35
, pp. 4
-
-
Snyder, R.W.1
Noecker, R.J.2
Jones, H.3
-
5
-
-
0023245509
-
Accommodation of an endocapsular silicone lens (phacoersatz) in the nonhuman primate
-
5 Haefliger E, Parel JM, Fantes F, et al.: Accommodation of an endocapsular silicone lens (phacoersatz) in the nonhuman primate. Ophthalmology 1987, 94:471-477.
-
(1987)
Ophthalmology
, vol.94
, pp. 471-477
-
-
Haefliger, E.1
Parel, J.M.2
Fantes, F.3
-
7
-
-
0025931101
-
Laser phacolysis of the human cataractous lens
-
7 Dodick JM: Laser phacolysis of the human cataractous lens. Dev Ophthalmol 1991, 22:58-64.
-
(1991)
Dev Ophthalmol
, vol.22
, pp. 58-64
-
-
Dodick, J.M.1
-
9
-
-
0031050466
-
Modeling of erbium:YAG laser-mediated explosive photovaporization
-
The authors used a model for laser-generated bubble expansion and studied ablation rate and thermometry. They demonstrated that tissue ablation depends on radiant exposure, whereas temperature increases, bubble size, and peak pressure depend on total pulse energy. They recommend that efficient ablation can be achieved by delivering low-pulse energy at high repetition rates
-
9 Berger JW, D'Amico DJ: Modeling of Erbium:YAG laser-mediated explosive photovaporization. Ophthalmic Surg Lasers 1997, 28:133-139. The authors used a model for laser-generated bubble expansion and studied ablation rate and thermometry. They demonstrated that tissue ablation depends on radiant exposure, whereas temperature increases, bubble size, and peak pressure depend on total pulse energy. They recommend that efficient ablation can be achieved by delivering low-pulse energy at high repetition rates.
-
(1997)
Ophthalmic Surg Lasers
, vol.28
, pp. 133-139
-
-
Berger, J.W.1
D'Amico, D.J.2
-
10
-
-
0021797662
-
Excimer laser ablation of the cornea and lens: Experimental studies
-
10 Puliafito CA, Steinert RF, Deutsch TF, et al.: Excimer laser ablation of the cornea and lens: experimental studies. Ophthalmology 1985, 92:741-748.
-
(1985)
Ophthalmology
, vol.92
, pp. 741-748
-
-
Puliafito, C.A.1
Steinert, R.F.2
Deutsch, T.F.3
-
13
-
-
0024343484
-
Excimer laser laser phakoablation of the human lens at 398 nm with a fiber delivery system
-
13 Maguen E, Martinez M. Grundfest W, et al.: Excimer laser laser phakoablation of the human lens at 398 nm with a fiber delivery system. J Cataract Refract Surg 1989, 15:409-414.
-
(1989)
J Cataract Refract Surg
, vol.15
, pp. 409-414
-
-
Maguen, E.1
Martinez, M.2
Grundfest, W.3
-
14
-
-
0028093048
-
Erbium: YAG laser and holmium laser ablation of the lens
-
14 Ross BS, Puliafito CA: Erbium: YAG laser and holmium laser ablation of the lens. Lasers Surg Med 1994, 15:74-82.
-
(1994)
Lasers Surg Med
, vol.15
, pp. 74-82
-
-
Ross, B.S.1
Puliafito, C.A.2
-
15
-
-
0029003773
-
Focal laser phacoablation of normal and cataractous lenses in rabbits: Preliminary report
-
15 Gwon A, Frankhauser F, Puliafito CA, et al.: Focal laser phacoablation of normal and cataractous lenses in rabbits: preliminary report. J Cataract Refract Surg 1995, 21:282-286.
-
(1995)
J Cataract Refract Surg
, vol.21
, pp. 282-286
-
-
Gwon, A.1
Frankhauser, F.2
Puliafito, C.A.3
-
17
-
-
0023265944
-
Effects of an erbium: YAG laser on ocular structures
-
17 Peyman GA, Katoh N: Effects of an erbium: YAG laser on ocular structures. Int Ophthalmol 1987, 10:245-253.
-
(1987)
Int Ophthalmol
, vol.10
, pp. 245-253
-
-
Peyman, G.A.1
Katoh, N.2
-
18
-
-
0025301391
-
Application of erbium: YAG laser in ocular ablation
-
18 Tsubota K: Application of erbium: YAG laser in ocular ablation. Ophthalmologica 1990, 200:117-122.
-
(1990)
Ophthalmologica
, vol.200
, pp. 117-122
-
-
Tsubota, K.1
|