메뉴 건너뛰기




Volumn 70, Issue 1, 1999, Pages 37-41

The external spinal fixator does not reduce anterior column motion under axial compressive loads. A mechanical in vitro study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANALGESIA; ARTICLE; BACKACHE; CADAVER; CLINICAL ARTICLE; COMPRESSION; DISTRACTION OSTEOGENESIS; EXTERNAL FIXATOR; FRACTURE EXTERNAL FIXATION; HUMAN; HUMAN TISSUE; LOADING TEST; LUMBAR SPINE; MOTION; ORTHOPEDIC EQUIPMENT; SPINE STABILIZATION; VERTEBRA;

EID: 0033022653     PISSN: 00016470     EISSN: None     Source Type: Journal    
DOI: 10.3109/17453679909000955     Document Type: Article
Times cited : (7)

References (17)
  • 1
    • 0030022015 scopus 로고    scopus 로고
    • Mechanics of the external fixation test in the lumbar spine: A roentgen stereophoto-grammetric analysis
    • Axelsson P, Johnsson R, Strömqvist B. Mechanics of the external fixation test in the lumbar spine: A roentgen stereophoto-grammetric analysis. Spine 1996; 21 (3): 330-3.
    • (1996) Spine , vol.21 , Issue.3 , pp. 330-333
    • Axelsson, P.1    Johnsson, R.2    Strömqvist, B.3
  • 2
    • 0030022483 scopus 로고    scopus 로고
    • External spinal skeletal fixation in the management of back pain
    • Bednar D A, Raducan V. External spinal skeletal fixation in the management of back pain. Clin Orthop 1996; 322: 131-45.
    • (1996) Clin Orthop , vol.322 , pp. 131-145
    • Bednar, D.A.1    Raducan, V.2
  • 3
    • 0024352335 scopus 로고
    • The role of external spinal skeletal fixation in the assessment of low-back disorders
    • Esses S I, Botsford D J, Kostuik J P. The role of external spinal skeletal fixation in the assessment of low-back disorders. Spine 1989; 14: 594-601.
    • (1989) Spine , vol.14 , pp. 594-601
    • Esses, S.I.1    Botsford, D.J.2    Kostuik, J.P.3
  • 4
    • 0028292805 scopus 로고
    • Percutaneous diagnostic stabilization for low back pain. Correlation with results after fusion operations
    • Jeanneret B, Jovanovic M, Magerl F. Percutaneous diagnostic stabilization for low back pain. Correlation with results after fusion operations. Clin Orthop 1994; 304: 130-8.
    • (1994) Clin Orthop , vol.304 , pp. 130-138
    • Jeanneret, B.1    Jovanovic, M.2    Magerl, F.3
  • 5
    • 0025853545 scopus 로고
    • The tissue origin of low-back pain and sciatica: A report of pain response to tissue stimulation during operations on the lumbar spine using local anesthesia
    • Kuslich S D, Ulström C L, Michael C J. The tissue origin of low-back pain and sciatica: A report of pain response to tissue stimulation during operations on the lumbar spine using local anesthesia. Orthop Clin North Am 1991: 181-7.
    • (1991) Orthop Clin North Am , pp. 181-187
    • Kuslich, S.D.1    Ulström, C.L.2    Michael, C.J.3
  • 6
    • 0003011414 scopus 로고
    • External skeletal fixation of the lower thoracic and the lumbar spine
    • (Ed. Uhthoff H K). Springer, Berlin, Heidelberg, New York
    • Magerl F P. External skeletal fixation of the lower thoracic and the lumbar spine. In: Current Concepts of External Fixation of Fractures (Ed. Uhthoff H K). Springer, Berlin, Heidelberg, New York 1982: 353-66.
    • (1982) Current Concepts of External Fixation of Fractures , pp. 353-366
    • Magerl, F.P.1
  • 7
    • 0013888190 scopus 로고
    • The load on lumbar disks in different positions of the body
    • Nachemson A. The load on lumbar disks in different positions of the body. Clin Orthop 1966; 45: 107-22.
    • (1966) Clin Orthop , vol.45 , pp. 107-122
    • Nachemson, A.1
  • 8
    • 0022625440 scopus 로고
    • Spontaneous effect of increased stability of the lower lumbar spine in cases of severe chronic back pain. The answer of an external transpeduncular fixation test
    • Olerud S, Sjöström L, Karlström G, Hamberg M. Spontaneous effect of increased stability of the lower lumbar spine in cases of severe chronic back pain. The answer of an external transpeduncular fixation test. Clin Orthop 1986; 203: 67-74.
    • (1986) Clin Orthop , vol.203 , pp. 67-74
    • Olerud, S.1    Sjöström, L.2    Karlström, G.3    Hamberg, M.4
  • 10
    • 0000446963 scopus 로고
    • Stabilization of the lower thoracic and lumbar spine: Comparative in vitro investigation of an external skeletal and various internal fixation devices
    • (Ed. Uhthoff H K). Springer, Berlin, Heidelberg, New York
    • Schläpfer F, Wörsdörfer O, Magerl F, Perren S M. Stabilization of the lower thoracic and lumbar spine: Comparative in vitro investigation of an external skeletal and various internal fixation devices. In: Current Concepts of External Fixation of Fractures (Ed. Uhthoff H K). Springer, Berlin, Heidelberg, New York 1982: 367-85.
    • (1982) Current Concepts of External Fixation of Fractures , pp. 367-385
    • Schläpfer, F.1    Wörsdörfer, O.2    Magerl, F.3    Perren, S.M.4
  • 11
    • 0019364174 scopus 로고
    • Analysis of loads on the lumbar spine
    • Schultz A, Andersson G B J. Analysis of loads on the lumbar spine. Spine 1981; 6 (1): 76-82.
    • (1981) Spine , vol.6 , Issue.1 , pp. 76-82
    • Schultz, A.1    Andersson, G.B.J.2
  • 12
    • 70449253829 scopus 로고
    • Sciatica and the intervertebral disc
    • Smyth M, Wright V. Sciatica and the intervertebral disc. J Bone Joint Surg (Am). 1958; 40: 1401-18.
    • (1958) J Bone Joint Surg (Am) , vol.40 , pp. 1401-1418
    • Smyth, M.1    Wright, V.2
  • 13
    • 0027186083 scopus 로고
    • External transpedicular fixation test of the lumbar spine correlates with the outcome of subsequent lumbar fusion
    • Soini J, Slätis P, Kannisto M, Sandelin J. External transpedicular fixation test of the lumbar spine correlates with the outcome of subsequent lumbar fusion. Clin Orthop 1993; 293: 89-96.
    • (1993) Clin Orthop , vol.293 , pp. 89-96
    • Soini, J.1    Slätis, P.2    Kannisto, M.3    Sandelin, J.4
  • 14
    • 0029940478 scopus 로고    scopus 로고
    • Steifigkeit des AO wirbelfixateur externe. Experimentelle ergebnisse zur steifigkeit des AO wirbelfixateur externe mit drei verschiedenen pedikelschraubensystemen
    • Stalder H, Jacob H A C, Leu H J. Steifigkeit des AO wirbelfixateur externe. Experimentelle ergebnisse zur steifigkeit des AO wirbelfixateur externe mit drei verschiedenen pedikelschraubensystemen. Z Orthop 1996; 134: 177-84.
    • (1996) Z Orthop , vol.134 , pp. 177-184
    • Stalder, H.1    Jacob, H.A.C.2    Leu, H.J.3
  • 17
    • 0000814092 scopus 로고
    • Back pain in relation to the nerve supply of the intervertebral disc
    • Wiberg G. Back pain in relation to the nerve supply of the intervertebral disc. Acta Orthop Scand 1950; 19: 211-21.
    • (1950) Acta Orthop Scand , vol.19 , pp. 211-221
    • Wiberg, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.