메뉴 건너뛰기




Volumn 51, Issue 6, 1999, Pages 341-347

Evaluation of measured and calculated creatinine clearances as glomerular filtration markers in different stages of liver cirrhosis

Author keywords

Cockcroft and Gault formula; Creatinine clearance; Inulin clearance; Liver cirrhosis

Indexed keywords

CREATINE; CREATININE;

EID: 0033019441     PISSN: 03010430     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (57)

References (21)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG 1986 Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 0021994590 scopus 로고
    • Current status on assessment and measurement of glomerular filtration rate
    • Broechner-Mortensen J 1985 Current status on assessment and measurement of glomerular filtration rate. Clin Physiol 5: 1-17
    • (1985) Clin Physiol , vol.5 , pp. 1-17
    • Broechner-Mortensen, J.1
  • 4
    • 0016916438 scopus 로고
    • Prediction of creatinine clearance from serum creatinine
    • Cockcroft DW, Gault MH 1976 Prediction of creatinine clearance from serum creatinine. Nephron 16: 31-41
    • (1976) Nephron , vol.16 , pp. 31-41
    • Cockcroft, D.W.1    Gault, M.H.2
  • 5
    • 0019784961 scopus 로고
    • A peck at the Child-Turcott classification
    • Conn HO 1981 A peck at the Child-Turcott classification. Hepatology 6: 673-676
    • (1981) Hepatology , vol.6 , pp. 673-676
    • Conn, H.O.1
  • 7
    • 0029145728 scopus 로고
    • Creatinine clearance: An inadequate marker of renal filtration in patients with early posthepatitic cirrhosis (child A) without fluid retention and muscle wasting
    • De Santo N, Anastasio P, Loguercio C, Spitali L, Del Vecchio Blanco C, Corvinelli M, Cirillo M 1995 Creatinine clearance: an inadequate marker of renal filtration in patients with early posthepatitic cirrhosis (Child A) without fluid retention and muscle wasting. Nephron 70: 421-424
    • (1995) Nephron , vol.70 , pp. 421-424
    • De Santo, N.1    Anastasio, P.2    Loguercio, C.3    Spitali, L.4    Del Vecchio Blanco, C.5    Corvinelli, M.6    Cirillo, M.7
  • 8
    • 33744839368 scopus 로고
    • A formula to estimate the approximate surface area if height and weight are known
    • DuBois D, DuBois EF 1916 A formula to estimate the approximate surface area if height and weight are known. Arch Intern Med 17: 863-871
    • (1916) Arch Intern Med , vol.17 , pp. 863-871
    • DuBois, D.1    DuBois, E.F.2
  • 9
    • 84945736974 scopus 로고
    • Multicenter evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent
    • Guder WG, Hoffmann GE, Hubbuch A, Poppe WA, Siedel J, Price CP 1986 Multicenter evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent. J Clin Chem Clin Biochem 24: 889-902
    • (1986) J Clin Chem Clin Biochem , vol.24 , pp. 889-902
    • Guder, W.G.1    Hoffmann, G.E.2    Hubbuch, A.3    Poppe, W.A.4    Siedel, J.5    Price, C.P.6
  • 11
    • 0025236580 scopus 로고
    • Refinements of assays for low concentrations of inulin in serum
    • Jung K, Klotzek S, Schulze BD 1990 Refinements of assays for low concentrations of inulin in serum. Nephron 54: 360-361
    • (1990) Nephron , vol.54 , pp. 360-361
    • Jung, K.1    Klotzek, S.2    Schulze, B.D.3
  • 12
    • 0000367742 scopus 로고
    • Clearance techniques
    • Windhager EE(ed). Oxford University Press, Oxford, Section 8
    • Levinski NG, Lieberthal W 1992 Clearance techniques. In: Windhager EE(ed): Handbook of Physiology. Oxford University Press, Oxford, Section 8, Vol 1, pp 226-247
    • (1992) Handbook of Physiology , vol.1 , pp. 226-247
    • Levinski, N.G.1    Lieberthal, W.2
  • 14
    • 0023634583 scopus 로고
    • Unpredictability of clinical evaluation of renal function in cirrhosis
    • Papadakis MA, Arieff AI 1987 Unpredictability of clinical evaluation of renal function in cirrhosis. Am J Med 82: 945-952
    • (1987) Am J Med , vol.82 , pp. 945-952
    • Papadakis, M.A.1    Arieff, A.I.2
  • 15
    • 0026442320 scopus 로고
    • Serum creatinine as an index of renal function: New insights into old concepts
    • Perrone RD, Madias NE, Levey AS 1992 Serum creatinine as an index of renal function: new insights into old concepts. Clin Chem 38: 1933-1953
    • (1992) Clin Chem , vol.38 , pp. 1933-1953
    • Perrone, R.D.1    Madias, N.E.2    Levey, A.S.3
  • 16
    • 0024472202 scopus 로고
    • Prediction of creatinine clearance from plasma creatinine: Comparison of five formulae
    • Robertshaw M, Lai KN, Swaminathan R 1989 Prediction of creatinine clearance from plasma creatinine: comparison of five formulae. Br J Clin Pharmac 28: 275-280
    • (1989) Br J Clin Pharmac , vol.28 , pp. 275-280
    • Robertshaw, M.1    Lai, K.N.2    Swaminathan, R.3
  • 18
    • 0029618259 scopus 로고
    • Conventional measurement of renal function utilizing serum creatinine, creatinine clearance' inulin and para-aminohippuric acid clearance
    • Toto RD 1995 Conventional measurement of renal function utilizing serum creatinine, creatinine clearance' inulin and para-aminohippuric acid clearance. Curr Opin Nephrol Hypertens 4: 505-509
    • (1995) Curr Opin Nephrol Hypertens , vol.4 , pp. 505-509
    • Toto, R.D.1
  • 19
    • 0019819005 scopus 로고
    • Measurement of the renal clearance of drugs
    • Tucker GT 1981 Measurement of the renal clearance of drugs. Br J Clin Pharmac 12: 761-770
    • (1981) Br J Clin Pharmac , vol.12 , pp. 761-770
    • Tucker, G.T.1
  • 20
    • 0028957682 scopus 로고
    • Drawbacks of the constant-infusion technique for measurement of renal function
    • van Acker B, Koomen GCM, Arisz L 1995 Drawbacks of the constant-infusion technique for measurement of renal function. Am J Physiol 268: F543-F552
    • (1995) Am J Physiol , vol.268
    • Van Acker, B.1    Koomen, G.C.M.2    Arisz, L.3
  • 21
    • 0025893319 scopus 로고
    • Interferences in current methods for measurements of creatinine
    • Weber JA, van Zanten AP 1991 Interferences in current methods for measurements of creatinine. Clin Chem 37: 695-700
    • (1991) Clin Chem , vol.37 , pp. 695-700
    • Weber, J.A.1    Van Zanten, A.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.