-
3
-
-
0027761601
-
-
A. Ishida Description and measurement of anatomical joint motion Frontiers Med. Biol. Eng. 5 161 1173 1993
-
(1993)
, vol.5
, pp. 161-1173
-
-
Ishida, A.1
-
4
-
-
0025568713
-
-
D. J. Kriegman J. Ponce On recognizing and positioning curved 3-D objects from image contours IEEE Trans. Pattern Anal. Machine Intell. 12 1127 1137 1990 34 2279 62602
-
(1990)
, vol.12
, pp. 1127-1137
-
-
Kriegman, D.J.1
Ponce, J.2
-
5
-
-
0022929717
-
-
G. A. Wood R. N. Marshall The accuracy of DLT extrapolation in three dimensional film analysis J. Biomech. 19 781 785 1986
-
(1986)
, vol.19
, pp. 781-785
-
-
Wood, G.A.1
Marshall, R.N.2
-
6
-
-
0026574554
-
-
J-N. Argenson J. J. O'Connor Polyethylene wear in meniscal knee replacement J. Bone Joint Surg. 74-B 228 232 1992
-
(1992)
, vol.74-B
, pp. 228-232
-
-
Argenson, J-N.1
O'Connor, J.J.2
-
7
-
-
0031081025
-
-
M. A. Wimmer T. P. Andriacchi Tractive forces during rolling motion of the knee: Implications for wear in total knee replacement J. Biomech. 30 131 137 1997
-
(1997)
, vol.30
, pp. 131-137
-
-
Wimmer, M.A.1
Andriacchi, T.P.2
-
8
-
-
0026328950
-
-
L. Mintz A. K. Tsao C. R. McCrae S. D. Stulberg T. Wright The arthroscopic evaluation and characteristics of severe polyethylene wear in total knee arthroplasty Clin. Orthoped. Related Res. 273 215 222 1991
-
(1991)
, Issue.273
, pp. 215-222
-
-
Mintz, L.1
Tsao, A.K.2
McCrae, C.R.3
Stulberg, S.D.4
Wright, T.5
-
9
-
-
0030175447
-
-
S. A. Banks W. A. Hodge Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy IEEE Trans. Biomed. Eng. 43 638 649 1996 10 10802 495283
-
(1996)
, vol.43
, pp. 638-649
-
-
Banks, S.A.1
Hodge, W.A.2
-
10
-
-
0029288672
-
-
S. Lavalle´e R. Szeliski Recovering the position and orientation of free-form objects from image contours using 3D distance maps IEEE Trans. Pattern Anal. Machine Intell. 17 378 390 1995 34 8745 385980
-
(1995)
, vol.17
, pp. 378-390
-
-
Lavalle´1
e, S.2
Szeliski, R.3
-
11
-
-
85176693571
-
-
Y. I. Abdel-Aziz H. M. Karara Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry Proc. ASP/UI Symp. Close Range Photogrammetry 1 18 1971
-
(1971)
, pp. 1-18
-
-
Abdel-Aziz, Y.I.1
Karara, H.M.2
-
12
-
-
85176677751
-
-
E. Y. Chao Justification of triaxial goniometer for the measurement of joint rotation J. Biomech. 13 1 18 1971
-
(1971)
, vol.13
, pp. 1-18
-
-
Chao, E.Y.1
-
13
-
-
0027497632
-
-
A. Tsao L. Mintz C. R. McRae D. Stulberg T. Wright Failure of the porous-coated anatomic prosthesis in total knee arthroplasty due to severe polyethylene wear J. Bone Joint Surg. 75-A 19 26 1993
-
(1993)
, vol.75-A
, pp. 19-26
-
-
Tsao, A.1
Mintz, L.2
McRae, C.R.3
Stulberg, D.4
Wright, T.5
-
14
-
-
85176672166
-
-
E. S. Grood W. J. Suntay A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee ASME J. Biomech. Eng. 15 1 18 1971
-
(1971)
, vol.15
, pp. 1-18
-
-
Grood, E.S.1
Suntay, W.J.2
-
15
-
-
0000238336
-
-
J. A. Nelder R. Mead A simplex method for function minimization Computer J. 7 308 313 1965
-
(1965)
, vol.7
, pp. 308-313
-
-
Nelder, J.A.1
Mead, R.2
-
16
-
-
0026527293
-
-
G. A. Engh K. A. Dwyer C. K. Hanes Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses J. Bone Joint Surg. 74-B 9 17 1992
-
(1992)
, vol.74-B
, pp. 9-17
-
-
Engh, G.A.1
Dwyer, K.A.2
Hanes, C.K.3
-
18
-
-
0029944403
-
-
S. A. Walker W. Hoff R. Komistek D. Dennis `In vivo' pose estimation of artificial knee implants using computer vision Biomed. Sci. Instrum. 32 143 150 1996
-
(1996)
, vol.32
, pp. 143-150
-
-
Walker, S.A.1
Hoff, W.2
Komistek, R.3
Dennis, D.4
-
19
-
-
85176688180
-
-
MD, Baltimore
-
A. H. Burstein T. M. Wright Fundamentals of Orthopaedic Biomechanics 1994 MD, Baltimore
-
(1994)
-
-
Burstein, A.H.1
Wright, T.M.2
|