Volumn 26, Issue 3, 1999, Pages 478-484

Optical density dependence on postirradiation temperature and time for MD-55-2 type radiochromic film

Author keywords

Film dosimetry; GAFChromic film; Optical density; Radiochromic film; Temperature dependence

Indexed keywords

DENSITOMETERS; DENSITY (OPTICAL); DENSITY MEASUREMENT (OPTICAL); LIGHT SOURCES; METEOROLOGICAL INSTRUMENTS; TEMPERATURE DISTRIBUTION;

EID: 0033018343     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598538     Document Type: Article
Times cited : (19)

References (12)
  • 2
    • 0025895699 scopus 로고
    • Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry
    • P. J. Muench, A. S. Meigooni, R. Nath, and W. L. McLaughlin, "Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry," Med. Phys. 18, 769-775 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 769-775
    • Muench, P.J.1    Meigooni, A.S.2    Nath, R.3    McLaughlin, W.L.4
  • 3
    • 0000331924 scopus 로고
    • The response of plastic dosimeters to gamma rays and electrons at high absorbed dose rates
    • W. L. McLaughlin, J. C. Humphreys, B. B. Radak, A. Miller, and T. A. Olejnik, "The response of plastic dosimeters to gamma rays and electrons at high absorbed dose rates," Radiat. Phys. Chem. 14, 535-550 (1979).
    • (1979) Radiat. Phys. Chem. , vol.14 , pp. 535-550
    • McLaughlin, W.L.1    Humphreys, J.C.2    Radak, B.B.3    Miller, A.4    Olejnik, T.A.5
  • 4
    • 0002875604 scopus 로고
    • The measurement of absorbed dose and dose gradients
    • W. L. McLaughlin, "The measurement of absorbed dose and dose gradients," Radiat. Phys. Chem. 15, 9-38 (1980).
    • (1980) Radiat. Phys. Chem. , vol.15 , pp. 9-38
    • McLaughlin, W.L.1
  • 6
    • 0011681527 scopus 로고
    • Radiochromic film densitometry for high dose-rate Ir-192 dosimetry: Accuracy and precision
    • V. Mishra, J. F. Williamson, Z. Li, and A. S. Meigooni, "Radiochromic film densitometry for high dose-rate Ir-192 dosimetry: Accuracy and precision," Med. Phys. 20, 865 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 865
    • Mishra, V.1    Williamson, J.F.2    Li, Z.3    Meigooni, A.S.4
  • 7
  • 8
    • 0029832035 scopus 로고    scopus 로고
    • Dosimetric characteristics of an improved radiochromic film
    • A. S. Meigooni, M. F. Sanders, G. S. Ibbott, and S. R. Szeglin, "Dosimetric characteristics of an improved radiochromic film," Med. Phys. 23, 1883-1888 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1883-1888
    • Meigooni, A.S.1    Sanders, M.F.2    Ibbott, G.S.3    Szeglin, S.R.4
  • 11
    • 0031045089 scopus 로고    scopus 로고
    • Quantitative evaluation of radiochromic film response for two-dimensional dosimetry
    • Y. Zhu, A. S. Kirov, V. Mishra, A. S. Meigooni, and J. F. Williamson, "Quantitative evaluation of radiochromic film response for two-dimensional dosimetry," Med. Phys. 24, 223-231 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 223-231
    • Zhu, Y.1    Kirov, A.S.2    Mishra, V.3    Meigooni, A.S.4    Williamson, J.F.5
  • 12
    • 0031466420 scopus 로고    scopus 로고
    • Gafchromic MD-55: Investigated as a precision dosimeter
    • N. V. Klassen, L. van der Zwan, and J. Cygler, "GafChromic MD-55: Investigated as a precision dosimeter," Med. Phys. 24, 1924-1934 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1924-1934
    • Klassen, N.V.1    Van Der Zwan, L.2    Cygler, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.