메뉴 건너뛰기




Volumn 9, Issue 2, 1999, Pages 185-190

In vitro measurement of muscle volume with 3-dimensional ultrasound

Author keywords

3 D ultrasound; Muscle; Volume measurements

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; ECHOGRAPHY; HAND MUSCLE; HUMAN; HUMAN TISSUE; IMAGE QUALITY; IN VITRO STUDY; MUSCLE ATROPHY; MUSCLE MASS; OBSERVER VARIATION; PRIORITY JOURNAL; RELIABILITY; THREE DIMENSIONAL IMAGING;

EID: 0033015390     PISSN: 09298266     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0929-8266(99)00023-3     Document Type: Article
Times cited : (25)

References (10)
  • 1
    • 0028292321 scopus 로고
    • Quantification of atherosclerotic plaques in carotid arteries by three-dimensional ultrasound
    • Delcker A., Diener H.C. Quantification of atherosclerotic plaques in carotid arteries by three-dimensional ultrasound. Br. J. Radiol. 67:1994;672-678.
    • (1994) Br. J. Radiol. , vol.67 , pp. 672-678
    • Delcker, A.1    Diener, H.C.2
  • 2
    • 0004441572 scopus 로고    scopus 로고
    • 3D-ultrasound of carotid artery using a sensor as a space orientation
    • Delcker A, Polz H. 3D-ultrasound of carotid artery using a sensor as a space orientation. Cerebrovasc Dis 1996;6 Suppl 3:2.
    • (1996) Cerebrovasc Dis , vol.6 , Issue.SUPPL 3 , pp. 2
    • Delcker, A.1    Polz, H.2
  • 4
    • 0345343417 scopus 로고    scopus 로고
    • Real-time neuromuscular sonography: Technique, normals, and pathology
    • In: Tegeler CH, Babikian VL, Gomez CR, editors. Mosby, St. Louis
    • Fischer A. Real-time neuromuscular sonography: Technique, normals, and pathology. In: Tegeler CH, Babikian VL, Gomez CR, editors. Neurosonology. Mosby, St. Louis, 1996:397-405.
    • (1996) Neurosonology , pp. 397-405
    • Fischer, A.1
  • 5
    • 0028131916 scopus 로고
    • Neurophysiological studies of intramuscular botulinum-A toxin in man
    • Hamjian J.A., Walker F.O. Neurophysiological studies of intramuscular botulinum-A toxin in man. Muscle Nerve. 17:1994;1385-1392.
    • (1994) Muscle Nerve , vol.17 , pp. 1385-1392
    • Hamjian, J.A.1    Walker, F.O.2
  • 6
    • 0018897001 scopus 로고
    • Detection of pathological change in dystrophic muscle with B-scan ultrasound imaging
    • Heckmatt J.Z., Dubovitz V., Leeman S. Detection of pathological change in dystrophic muscle with B-scan ultrasound imaging. Lancet. 1:1980;1389-1390.
    • (1980) Lancet , vol.1 , pp. 1389-1390
    • Heckmatt, J.Z.1    Dubovitz, V.2    Leeman, S.3
  • 7
    • 0019987476 scopus 로고
    • Ultrasound imaging in the diagnosis of muscle disease
    • Heckmatt J.Z., Leeman S., Dubowitz V. Ultrasound imaging in the diagnosis of muscle disease. J. Pediatr. 101:1982;656-660.
    • (1982) J. Pediatr. , vol.101 , pp. 656-660
    • Heckmatt, J.Z.1    Leeman, S.2    Dubowitz, V.3
  • 8
  • 10
    • 0345154364 scopus 로고
    • Sonographic imaging of cervical muscles following botulinum toxin injections
    • Walker F, Hunt V. Sonographic imaging of cervical muscles following botulinum toxin injections. Muscle Nerve 1994;17 Suppl 1: 112.
    • (1994) Muscle Nerve , vol.17 , Issue.SUPPL 1 , pp. 112
    • Walker, F.1    Hunt, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.