메뉴 건너뛰기




Volumn 51, Issue 6, 1999, Pages 659-664

Revision and removal of stimulating electrodes following long-term therapy with the vagus nerve stimulator

Author keywords

Electrical stimulation; Epilepsy; Epilepsy surgery; Neurocybernetic prosthesis; Seizures; Vagus nerve

Indexed keywords

ADULT; ARTICLE; ELECTRODE; FEMALE; HUMAN; IMPLANTATION; INTRACTABLE EPILEPSY; MALE; NERVE INJURY; PROSTHESIS FAILURE; SEIZURE; SURGICAL TECHNIQUE; VAGUS NERVE STIMULATION;

EID: 0033013708     PISSN: 00903019     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0090-3019(99)00046-4     Document Type: Article
Times cited : (66)

References (8)
  • 1
    • 0028338859 scopus 로고
    • Vagus nerve stimulation for treatment of partial seizures: A controlled study of effect on seizures
    • Ben-Menachem E., Mañon-Espaillat R., Ristanovic R., et al. Vagus nerve stimulation for treatment of partial seizures a controlled study of effect on seizures . Epilepsia. 35:1994;616-626.
    • (1994) Epilepsia , vol.35 , pp. 616-626
    • Ben-Menachem, E.1    Mañon-Espaillat, R.2    Ristanovic, R.3
  • 4
    • 0031867122 scopus 로고    scopus 로고
    • Vagus nerve stimulation therapy for partial-onset seizures; A randomized active-control trial
    • Handforth A., DeGiorgio C.M., Schachter S., et al. Vagus nerve stimulation therapy for partial-onset seizures; a randomized active-control trial. Neurol. 51:1998;48-55.
    • (1998) Neurol , vol.51 , pp. 48-55
    • Handforth, A.1    Degiorgio, C.M.2    Schachter, S.3
  • 5
    • 24844438822 scopus 로고
    • Minimal changes to the vagus nerve and brainstem after two years of stimulation
    • Mañon-Espaillat R., Hoenig E., Zabara J., Rosenwasser M. Minimal changes to the vagus nerve and brainstem after two years of stimulation. Epilepsia. 33:(S3):1992;S100.
    • (1992) Epilepsia , vol.33 , Issue.S3 , pp. 100
    • Mañon-Espaillat, R.1    Hoenig, E.2    Zabara, J.3    Rosenwasser, M.4
  • 6
    • 0000787693 scopus 로고    scopus 로고
    • Testing of MRI compatibility of the Cyberonics Model 100 NCP Generator and Model 300 Series Lead
    • Nyenhuis J.A., Bourland J.D., Foster K.S., Graber G.P., Terry R.S., Adkins R.A. Testing of MRI compatibility of the Cyberonics Model 100 NCP Generator and Model 300 Series Lead. Epilepsia. 38:(S8):1997;140.
    • (1997) Epilepsia , vol.38 , Issue.S8 , pp. 140
    • Nyenhuis, J.A.1    Bourland, J.D.2    Foster, K.S.3    Graber, G.P.4    Terry, R.S.5    Adkins, R.A.6
  • 7
    • 0028307219 scopus 로고
    • Vagus nerve stimulation for treatment of partial seizures: Safety, side effects, and tolerability
    • Ramsay R.E., Uthman B.M., Augustinsson L.E., et al. Vagus nerve stimulation for treatment of partial seizures safety, side effects, and tolerability . Epilepsia. 35:1994;627-636.
    • (1994) Epilepsia , vol.35 , pp. 627-636
    • Ramsay, R.E.1    Uthman, B.M.2    Augustinsson, L.E.3
  • 8
    • 0025204584 scopus 로고
    • Surgical technique for implantation of the Neurocybernetic Prosthesis
    • Reid S.A. Surgical technique for implantation of the Neurocybernetic Prosthesis. Epilepsia. 31:(S2):1990;S38-S39.
    • (1990) Epilepsia , vol.31 , Issue.S2
    • Reid, S.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.