메뉴 건너뛰기




Volumn 34, Issue 3, 1999, Pages 211-217

Automatic detection of left ventricular contours from cardiac cine magnetic resonance imaging using fuzzy logic

Author keywords

Cardiac image processing; Ejection fraction; Fuzzy logic; Magnetic resonance imaging

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION FUNCTION; ENDOCARDIUM; EPICARDIUM; HEART LEFT VENTRICLE; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0033012517     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199903000-00010     Document Type: Article
Times cited : (30)

References (18)
  • 1
    • 0027162484 scopus 로고
    • Quantification of the left ventricular volumes and function with cine MR imaging: Comparison of geometric models with three-dimensional data
    • Dulce MC, Mostbeck GH, Friese KK, Caputo GR, Higgins CB. Quantification of the left ventricular volumes and function with cine MR imaging: Comparison of geometric models with three-dimensional data. Radiology 1993;188:371-376.
    • (1993) Radiology , vol.188 , pp. 371-376
    • Dulce, M.C.1    Mostbeck, G.H.2    Friese, K.K.3    Caputo, G.R.4    Higgins, C.B.5
  • 2
    • 0023864999 scopus 로고
    • Functional evaluation of the heart with magnetic resonance imaging
    • Higgins CB, Holt W, Pflugfelder P, Sechtem U. Functional evaluation of the heart with magnetic resonance imaging. Magn Reson Med 1988;6:121-139.
    • (1988) Magn Reson Med , vol.6 , pp. 121-139
    • Higgins, C.B.1    Holt, W.2    Pflugfelder, P.3    Sechtem, U.4
  • 3
    • 0031041484 scopus 로고    scopus 로고
    • Detection and quantification of dysfunctional myocardium by magnetic resonance imaging
    • Holman ER, Buller VGM, de Roos A, et al. Detection and quantification of dysfunctional myocardium by magnetic resonance imaging. Circulation 1997;95:924-931.
    • (1997) Circulation , vol.95 , pp. 924-931
    • Holman, E.R.1    Buller, V.G.M.2    De Roos, A.3
  • 4
    • 0031459542 scopus 로고    scopus 로고
    • Comparison between manual and semiautomated analysis of left ventricular volume parameters from short-axis MR images
    • van der Geest RJ, Buller VGM, Jansen E, et al. Comparison between manual and semiautomated analysis of left ventricular volume parameters from short-axis MR Images. J Comput Assist Tomogr 1997;21:756-765.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 756-765
    • Van Der Geest, R.J.1    Buller, V.G.M.2    Jansen, E.3
  • 5
    • 0026029025 scopus 로고
    • Automated identification of left ventricular borders from spin-echo magnetic resonance images
    • Fleagle SR, Thedens DR, Ehrhrardt JC, Scholz TD, Skorton DJ. Automated identification of left ventricular borders from spin-echo magnetic resonance images. Invest Radiol 1991;26:295-303.
    • (1991) Invest Radiol , vol.26 , pp. 295-303
    • Fleagle, S.R.1    Thedens, D.R.2    Ehrhrardt, J.C.3    Scholz, T.D.4    Skorton, D.J.5
  • 6
    • 0021848796 scopus 로고
    • Left ventricular border recognition using a dynamic search algorithm
    • Pope DL, Parker DL, Clayton PD, Gustafson DE. Left ventricular border recognition using a dynamic search algorithm. Radiology 1985;155:513-518.
    • (1985) Radiology , vol.155 , pp. 513-518
    • Pope, D.L.1    Parker, D.L.2    Clayton, P.D.3    Gustafson, D.E.4
  • 8
    • 0029269575 scopus 로고
    • Segmentation of cardiac cine MR images for extraction of right and left ventricular chambers
    • Goshtasby A, Turner DA. Segmentation of cardiac cine MR Images for extraction of right and left ventricular chambers. IEEE Trans Med Imaging 1995;14:56-64.
    • (1995) IEEE Trans Med Imaging , vol.14 , pp. 56-64
    • Goshtasby, A.1    Turner, D.A.2
  • 9
    • 0029536595 scopus 로고
    • Fuzzy-based automatic detection of tags and ventricular contours for wall motion analysis of cardiac magnetic resonance images
    • Piva RMV, Kitney RI. Fuzzy-based automatic detection of tags and ventricular contours for wall motion analysis of cardiac Magnetic Resonance Images. IEEE Comput Cardiol 1995;237-240.
    • (1995) IEEE Comput Cardiol , pp. 237-240
    • Piva, R.M.V.1    Kitney, R.I.2
  • 11
    • 0030853657 scopus 로고    scopus 로고
    • Automated detection of the left ventricular region in magnetic resonance images by fuzzy C-means model
    • Boudraa Ae-O. Automated detection of the left ventricular region in magnetic resonance images by fuzzy C-means model. Int J Card Imaging 1997;13:347-355.
    • (1997) Int J Card Imaging , vol.13 , pp. 347-355
    • Boudraa, A.-O.1
  • 12
    • 0031362476 scopus 로고    scopus 로고
    • Automatic boundary detection of the left ventricle and measurement of local myocardial perfusion in MRI
    • Behloul F, Roux JP, Unterreiner R. Automatic boundary detection of the left ventricle and measurement of local myocardial perfusion in MRI. IEEE Comput Cardiol 1997;24:145-148.
    • (1997) IEEE Comput Cardiol , vol.24 , pp. 145-148
    • Behloul, F.1    Roux, J.P.2    Unterreiner, R.3
  • 13
    • 0026169483 scopus 로고
    • Epicardial boundary detection using fuzzy reasoning
    • Feng J, Lin W-C, Chen C-T. Epicardial boundary detection using fuzzy reasoning. IEEE Trans Med Imaging 1991;10:187-199.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 187-199
    • Feng, J.1    Lin, W.-C.2    Chen, C.-T.3
  • 14
    • 0029270928 scopus 로고
    • Fuzzy logic systems for engineering: A tutorial
    • Mendel MM. Fuzzy logic systems for engineering: A tutorial. Proc IEEE 1995;83:345-377.
    • (1995) Proc IEEE , vol.83 , pp. 345-377
    • Mendel, M.M.1
  • 16
    • 0346580208 scopus 로고    scopus 로고
    • Automatic detection of cardiac contours on MR images using fuzzy logic and dynamic programming
    • Masys DR, ed., Nashville. Hanley and Belfus, Inc.
    • Lalande A, Legrand L, Walker PM, et al. Automatic detection of cardiac contours on MR Images using fuzzy logic and dynamic programming. In: Masys DR, ed., Proceedings of the 1997 AMIA Annual Fall Symposium, Nashville. Hanley and Belfus, Inc., 1997; 474-478.
    • (1997) Proceedings of the 1997 AMIA Annual Fall Symposium , pp. 474-478
    • Lalande, A.1    Legrand, L.2    Walker, P.M.3
  • 17
    • 0015077742 scopus 로고
    • Computer determination of the constituent structure of biological images
    • Kirsch RA. Computer determination of the constituent structure of biological images. Comput Biomed Res 1971;4:315-328.
    • (1971) Comput Biomed Res , vol.4 , pp. 315-328
    • Kirsch, R.A.1
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;8:307-310.
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.