메뉴 건너뛰기




Volumn 14, Issue 2, 1999, Pages 220-226

Femoral bone blood flow after reaming and intramedullary canal preparation: A canine study using laser Doppler flowmetry

Author keywords

Bone blood flow; Intramedullary canal preparation; Laser Doppler flowmetry; Reaming

Indexed keywords

BONE CEMENT; METHACRYLIC ACID METHYL ESTER;

EID: 0033011988     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(99)90130-4     Document Type: Article
Times cited : (12)

References (33)
  • 1
    • 0022504244 scopus 로고
    • Treatment of tibial fractures by reaming and intramedullary nailing
    • Bone LB, Johnson KD: Treatment of tibial fractures by reaming and intramedullary nailing. J Bone Joint Surg Am 68:877, 1986
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 877
    • Bone, L.B.1    Johnson, K.D.2
  • 2
    • 0002947974 scopus 로고
    • Dilemmas and controversies in intramedullary nailing
    • Browner BD, Edwards CC (eds) Lea & Febiger, Philadelphia
    • Bucholz RW: Dilemmas and controversies in intramedullary nailing, p. 85. In Browner BD, Edwards CC (eds): The Science and practice of intramedullary nailing. Lea & Febiger, Philadelphia, 1987
    • (1987) The Science and Practice of Intramedullary Nailing , pp. 85
    • Bucholz, R.W.1
  • 3
    • 84988154652 scopus 로고
    • The role of intramedullary nailing in fracture management
    • Browner BD, Edwards CC (eds) Lea & Febiger, Philadelphia
    • Chapman MW: The role of intramedullary nailing in fracture management, p. 17. In Browner BD, Edwards CC (eds): The science and practice of intramedullary nailing. Lea & Febiger, Philadelphia, 1987
    • (1987) The Science and Practice of Intramedullary Nailing , pp. 17
    • Chapman, M.W.1
  • 6
    • 0025271047 scopus 로고
    • Bipolar arthroplasty for 496 hip fractures
    • Lestrange NR: Bipolar arthroplasty for 496 hip fractures. Clin Orthop Rel Res 251:7, 1990
    • (1990) Clin Orthop Rel Res , vol.251 , pp. 7
    • Lestrange, N.R.1
  • 7
    • 0025371623 scopus 로고
    • Comparison of bipolar implants with fixed-neck prosthesis in femoral neck fractures
    • Nottage WM, McMaster WC: Comparison of bipolar implants with fixed-neck prosthesis in femoral neck fractures. Clin Orthop Rel Res 251:38, 1990
    • (1990) Clin Orthop Rel Res , vol.251 , pp. 38
    • Nottage, W.M.1    McMaster, W.C.2
  • 8
    • 0015963022 scopus 로고
    • The normal circulation of bone and its response to surgical intervention
    • Rhinelander FW: The normal circulation of bone and its response to surgical intervention. J Biomed Mater Res 8:87, 1974
    • (1974) J Biomed Mater Res , vol.8 , pp. 87
    • Rhinelander, F.W.1
  • 9
    • 0016164585 scopus 로고
    • Tibial blood supply in relation to fracture healing
    • Rhinelander FW: Tibial blood supply in relation to fracture healing. Clin Orthop Rel Res 105:34, 1974
    • (1974) Clin Orthop Rel Res , vol.105 , pp. 34
    • Rhinelander, F.W.1
  • 11
    • 0001920572 scopus 로고
    • The vascular response of bone to internal fixation
    • Browner BD, Edwards CC (eds) Lea & Febiger, Philadelphia
    • Rhinelander FW: The vascular response of bone to internal fixation, p. 25. In Browner BD, Edwards CC (eds): The science and practice of intramedullary nailing. Lea & Febiger, Philadelphia, 1987
    • (1987) The Science and Practice of Intramedullary Nailing , pp. 25
    • Rhinelander, F.W.1
  • 12
    • 0019225916 scopus 로고
    • Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow
    • Nilsson GE, Tenland T, Oberg PA: Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow. IEEE Trans Biomed Eng 27:597, 1980
    • (1980) IEEE Trans Biomed Eng , vol.27 , pp. 597
    • Nilsson, G.E.1    Tenland, T.2    Oberg, P.A.3
  • 13
    • 0028528922 scopus 로고
    • Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: A fractured tibia model in sheep
    • Schemitsch EH, Kowalski MJ, Swiontkowski MF, et al: Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: a fractured tibia model in sheep. J Orthop Trauma 8:373, 1994
    • (1994) J Orthop Trauma , vol.8 , pp. 373
    • Schemitsch, E.H.1    Kowalski, M.J.2    Swiontkowski, M.F.3
  • 14
    • 0347429554 scopus 로고
    • Correlation of laser Doppler flowmetry with microsphere estimates for bone blood flow
    • Tsuchiya M, et al (eds) Elsevier Science Publishers, New York
    • Swiontkowski MF, Collins JC, Schlehr F, et al: Correlation of laser Doppler flowmetry with microsphere estimates for bone blood flow. p. 341. In Tsuchiya M, et al (eds): Microcirculation: an update. Elsevier Science Publishers, New York, 1987
    • (1987) Microcirculation: An Update , pp. 341
    • Swiontkowski, M.F.1    Collins, J.C.2    Schlehr, F.3
  • 15
    • 0023750087 scopus 로고
    • Comparison of two laser Doppler flowmetry systems for bone blood flow analysis
    • Swiontkowski MF, Schlehr F, Collins JC, et al: Comparison of two laser Doppler flowmetry systems for bone blood flow analysis. Calcif Tissue Int 43:103, 1988
    • (1988) Calcif Tissue Int , vol.43 , pp. 103
    • Swiontkowski, M.F.1    Schlehr, F.2    Collins, J.C.3
  • 16
    • 0023036459 scopus 로고
    • Laser Doppler flowmetry for bone blood flow measurement: Correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow
    • Swiontkowski MF, Tepic S, Perren SM, et al: Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow. J Orthop Res 4:362, 1986
    • (1986) J Orthop Res , vol.4 , pp. 362
    • Swiontkowski, M.F.1    Tepic, S.2    Perren, S.M.3
  • 17
    • 0024671914 scopus 로고
    • Laser doppler flowmetry for bone blood flow measurements: Helium-neon laser light attenuation and depth of perfusion assessment
    • Notzli HP, Swiontkowski MF, Thaxter ST, et al: Laser doppler flowmetry for bone blood flow measurements: helium-neon laser light attenuation and depth of perfusion assessment. J Orthop Res 7:413, 1989
    • (1989) J Orthop Res , vol.7 , pp. 413
    • Notzli, H.P.1    Swiontkowski, M.F.2    Thaxter, S.T.3
  • 18
    • 0014648238 scopus 로고
    • Reaming of the intramedullary cavity and its effect on diaphyseal bone
    • Danckwardt-Lilliestrom G: Reaming of the intramedullary cavity and its effect on diaphyseal bone. Acta Orthop Scand 128:1, 1969 (Suppl)
    • (1969) Acta Orthop Scand , vol.128 , Issue.SUPPL. , pp. 1
    • Danckwardt-Lilliestrom, G.1
  • 19
    • 0014868774 scopus 로고
    • Intracortical circulation after intramedullary reaming with reduction of pressure in the medullary cavity: A microangiographic study on the rabbit tibia
    • Danckwardt-Lilliestrom G, Lorenzi L, Olerud S: Intracortical circulation after intramedullary reaming with reduction of pressure in the medullary cavity: a microangiographic study on the rabbit tibia. J Bone Joint Surg Am 52:1390, 1970
    • (1970) J Bone Joint Surg Am , vol.52 , pp. 1390
    • Danckwardt-Lilliestrom, G.1    Lorenzi, L.2    Olerud, S.3
  • 20
    • 0007647053 scopus 로고
    • The effect of intramedullary nailing on the blood supply of the diaphysis of long bones in mature dogs
    • Gustilo RB, Nelson GE, Hamel A, et al: The effect of intramedullary nailing on the blood supply of the diaphysis of long bones in mature dogs. J Bone Joint Surg Am 46:1362, 1964
    • (1964) J Bone Joint Surg Am , vol.46 , pp. 1362
    • Gustilo, R.B.1    Nelson, G.E.2    Hamel, A.3
  • 21
    • 0022978144 scopus 로고
    • The effects of reaming and intramedullary nailing on fracture healing
    • Kessler SB, Hallfeldt KKJ, Perren SM, et al: The effects of reaming and intramedullary nailing on fracture healing. Clin Orthop 212:18, 1986
    • (1986) Clin Orthop , vol.212 , pp. 18
    • Kessler, S.B.1    Hallfeldt, K.K.J.2    Perren, S.M.3
  • 22
    • 0011735926 scopus 로고
    • The effect of reamed versus unreamed nailing on intramedullary blood supply and cortical viability
    • Sitter SR, Bronk JT, Kelly PJ: The effect of reamed versus unreamed nailing on intramedullary blood supply and cortical viability. J Orthop Trauma 4:232, 1990
    • (1990) J Orthop Trauma , vol.4 , pp. 232
    • Sitter, S.R.1    Bronk, J.T.2    Kelly, P.J.3
  • 23
    • 0025454632 scopus 로고
    • Effect of fracture fixation on cortical bone blood flow
    • Smith SR, Bronk JT, Kelly PJ: Effect of fracture fixation on cortical bone blood flow. J Orthop Res 8:471, 1990
    • (1990) J Orthop Res , vol.8 , pp. 471
    • Smith, S.R.1    Bronk, J.T.2    Kelly, P.J.3
  • 24
    • 0012374942 scopus 로고
    • Vascular changes caused by the Kuntscher type of nailing: An experimental study in the rabbit
    • Trueta J, Cavadias AX: Vascular changes caused by the Kuntscher type of nailing: an experimental study in the rabbit. J Bone Joint Surg Br 37:492, 1955
    • (1955) J Bone Joint Surg Br , vol.37 , pp. 492
    • Trueta, J.1    Cavadias, A.X.2
  • 25
    • 0006668775 scopus 로고
    • A physiological study of the blood supply of the diaphysis
    • Johnson RW Jr: A physiological study of the blood supply of the diaphysis. J Bone Joint Surg Br 9:153, 1927
    • (1927) J Bone Joint Surg Br , vol.9 , pp. 153
    • Johnson Jr., R.W.1
  • 26
    • 0000123919 scopus 로고
    • The role of the vessels in osteogenesis
    • Trueta J: The role of the vessels in osteogenesis. J Bone Joint Surg Br 45:402, 1963
    • (1963) J Bone Joint Surg Br , vol.45 , pp. 402
    • Trueta, J.1
  • 28
    • 0344396023 scopus 로고
    • 85 as a measure of effective bone blood flow
    • 85 as a measure of effective bone blood flow. Circ Res 16:461, 1965
    • (1965) Circ Res , vol.16 , pp. 461
    • Copp, D.H.1    Shim, S.S.2
  • 29
    • 0018972157 scopus 로고
    • An experimental model to study the relationship between blood flow and uptake for bone-seeking radionucleotides in normal bone
    • McCarthy ID, Hughes SPF, Orr JS: An experimental model to study the relationship between blood flow and uptake for bone-seeking radionucleotides in normal bone. Clin Phys Physiol Meas 1:135, 1980
    • (1980) Clin Phys Physiol Meas , vol.1 , pp. 135
    • McCarthy, I.D.1    Hughes, S.P.F.2    Orr, J.S.3
  • 30
    • 0020961894 scopus 로고
    • Microvascular response in cancellous bone to experimental halothane induced hypotension in pigs
    • Hellem S, Jacobsson LS, Nilsson GE: Microvascular response in cancellous bone to experimental halothane induced hypotension in pigs. Int J Oral Surg 12:178, 1983
    • (1983) Int J Oral Surg , vol.12 , pp. 178
    • Hellem, S.1    Jacobsson, L.S.2    Nilsson, G.E.3
  • 33
    • 0001397527 scopus 로고
    • Effects of medullary nailing on the normal blood supply of the diaphyseal cortex
    • Rhinelander FW: Effects of medullary nailing on the normal blood supply of the diaphyseal cortex. AAOS Instructional Course Lectures 22:161, 1973
    • (1973) AAOS Instructional Course Lectures , vol.22 , pp. 161
    • Rhinelander, F.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.