1
-
-
0029831869
-
Helical CT angiography compared with arteriography in the detection of renal artery stenosis
-
Beregi JP, Elkohen M, Deklunder G, et al. Helical CT angiography compared with arteriography in the detection of renal artery stenosis. AJR 1996; 167:495-501.
-
(1996)
AJR
, vol.167
, pp. 495-501
-
-
Beregi, J.P.1
Elkohen, M.2
Deklunder, G.3
-
2
-
-
0027458052
-
Renal arterial stenoses: Helical CT angiography
-
Galanski M, Prokop M, Chavan A, et al. Renal arterial stenoses: helical CT angiography. Radiology 1993; 189:185-192.
-
(1993)
Radiology
, vol.189
, pp. 185-192
-
-
Galanski, M.1
Prokop, M.2
Chavan, A.3
-
3
-
-
0028949273
-
Assessment of living renal donors with helical CT
-
Rubin GD, Alfrey EJ, Dake MD, et al. Assessment of living renal donors with helical CT. Radiology 1995; 195:457-462.
-
(1995)
Radiology
, vol.195
, pp. 457-462
-
-
Rubin, G.D.1
Alfrey, E.J.2
Dake, M.D.3
-
4
-
-
0028157491
-
Helical CT of renal artery stenosis: Comparison of three-dimensional rendering techniques
-
Rubin GD, Dake M, Napel S, et al. Helical CT of renal artery stenosis: comparison of three-dimensional rendering techniques. Radiology 1994; 190:181-189.
-
(1994)
Radiology
, vol.190
, pp. 181-189
-
-
Rubin, G.D.1
Dake, M.2
Napel, S.3
-
5
-
-
0030754687
-
Renal artery stenosis: Detection and quantification with helical CT angiography versus optimized digital subtraction angiography
-
Kantee R, Beck FJA, de Lange EE, et al. Renal artery stenosis: detection and quantification with helical CT angiography versus optimized digital subtraction angiography. Radiology 1997; 205:121-127.
-
(1997)
Radiology
, vol.205
, pp. 121-127
-
-
Kantee, R.1
Beck, F.J.A.2
De Lange, E.E.3
-
6
-
-
0028924797
-
Technical optimization of helical CT for depiction of renal artery stenosis: In vitro analysis
-
Brink JA, Lim JT, Wang G, et al. Technical optimization of helical CT for depiction of renal artery stenosis: in vitro analysis. Radiology 1995; 194:157-163.
-
(1995)
Radiology
, vol.194
, pp. 157-163
-
-
Brink, J.A.1
Lim, J.T.2
Wang, G.3
-
7
-
-
0031020289
-
A phantom study: Evaluation of renal artery stenosis using helical CT and 3D reconstructions
-
Davros WJ, Obuchowski NA, Berman PM, et al. A phantom study: evaluation of renal artery stenosis using helical CT and 3D reconstructions. J Comput Assist Tomogr 1997; 21:156-161.
-
(1997)
J Comput Assist Tomogr
, vol.21
, pp. 156-161
-
-
Davros, W.J.1
Obuchowski, N.A.2
Berman, P.M.3
-
8
-
-
0029890839
-
CT angiography with volume rendering: Advantages and applications in splanchnic vascular imaging
-
Johnson PT, Heath DG, Kuszyk BS, et al. CT angiography with volume rendering: advantages and applications in splanchnic vascular imaging. Radiology 1996; 200: 564-568.
-
(1996)
Radiology
, vol.200
, pp. 564-568
-
-
Johnson, P.T.1
Heath, D.G.2
Kuszyk, B.S.3
-
9
-
-
0029781840
-
Three-dimensional CT: Real-time interactive volume rendering
-
Johnson PT, Heath DG, Bliss DB, et al. Three-dimensional CT: real-time interactive volume rendering. AJR 1996; 167:581-583.
-
(1996)
AJR
, vol.167
, pp. 581-583
-
-
Johnson, P.T.1
Heath, D.G.2
Bliss, D.B.3
-
10
-
-
0006264282
-
CT angiography with volume rendering: In vitro optimization and evaluation of accuracy in quantifying stenoses
-
Kuszyk BS, Heath DG, Johnson PT, Fishman EK. CT angiography with volume rendering: in vitro optimization and evaluation of accuracy in quantifying stenoses (abstr). AJR 1997; 168(suppl):79.
-
(1997)
AJR
, vol.168
, Issue.SUPPL.
, pp. 79
-
-
Kuszyk, B.S.1
Heath, D.G.2
Johnson, P.T.3
Fishman, E.K.4
-
11
-
-
0344917087
-
Comparison of three rendering techniques in helical CT angiography: Surface-shaded display, maximum intensity projection, and 3D volume-rendering technique
-
Szeimies U, Kueffer GV, Steckmeier B, et al. Comparison of three rendering techniques in helical CT angiography: surface-shaded display, maximum intensity projection, and 3D volume-rendering technique (abstr). Radiology 1996; 201(P): 419.
-
(1996)
Radiology
, vol.201
, Issue.P
, pp. 419
-
-
Szeimies, U.1
Kueffer, G.V.2
Steckmeier, B.3
-
12
-
-
0024511244
-
Some practical issues of experimental design and data analysis in radiological ROC studies
-
Metz CT. Some practical issues of experimental design and data analysis in radiological ROC studies. Invest Radiol 1989; 24:234-245.
-
(1989)
Invest Radiol
, vol.24
, pp. 234-245
-
-
Metz, C.T.1
-
15
-
-
0029347998
-
Selecting a segmentation threshold for shaded surface display rendering of the renal arteries with CT angiography
-
Halpern EJ, Wechsler RJ, Di Campli D. Selecting a segmentation threshold for shaded surface display rendering of the renal arteries with CT angiography. J Digit Imaging 1995; 8:142-147.
-
(1995)
J Digit Imaging
, vol.8
, pp. 142-147
-
-
Halpern, E.J.1
Wechsler, R.J.2
Di Campli, D.3
-
16
-
-
0030028503
-
Potential renal donors: Comparison of conventional imaging with helical CT
-
Platt JF, Ellis JH, Korobkin M, et al. Potential renal donors: comparison of conventional imaging with helical CT. Radiology 1996; 198:419-423.
-
(1996)
Radiology
, vol.198
, pp. 419-423
-
-
Platt, J.F.1
Ellis, J.H.2
Korobkin, M.3
|