메뉴 건너뛰기




Volumn 22, Issue 1, 1999, Pages 35-39

Time-related contact angle measurements with human plasma on biomaterial surfaces

Author keywords

Biocompatibility; Biomaterials; Contact angle; Protein adsorption

Indexed keywords

ADHESION; ADSORPTION; ANGLE MEASUREMENT; BIOCOMPATIBILITY; DROPS; PHASE INTERFACES; PLASMA (HUMAN); PLATELETS; PROTEINS;

EID: 0033007160     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139889902200108     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 0028000324 scopus 로고
    • Thrombosis on foreign surfaces
    • Courtney JM, Forbes CD. Thrombosis on foreign surfaces. Br Med Bull 1994, 50; 4: 966-81
    • (1994) Br Med Bull , vol.50 , Issue.4 , pp. 966-981
    • Courtney, J.M.1    Forbes, C.D.2
  • 2
    • 0016411879 scopus 로고
    • The effects of chemical structure and surface properties of synthetic polymers on the coagulation of blood. IV. The relation between polymer morphology and protein adsorption
    • Lymann DJ, Knutson K, Mc Neil B, Shibatani K. The effects of chemical structure and surface properties of synthetic polymers on the coagulation of blood. IV. The relation between polymer morphology and protein adsorption. Trans Am Soc Artif Intern Organs 1975; 21: 49-54
    • (1975) Trans Am Soc Artif Intern Organs , vol.21 , pp. 49-54
    • Lymann, D.J.1    Knutson, K.2    Mc Neil, B.3    Shibatani, K.4
  • 4
    • 0030952184 scopus 로고    scopus 로고
    • Thromboembolic phenomena and the use of the pig as an appropriate animal model for research on cardiovascular devices
    • Gross DR. Thromboembolic phenomena and the use of the pig as an appropriate animal model for research on cardiovascular devices, Int J Artif Organs 1997, 20; 4:195-203
    • (1997) Int J Artif Organs , vol.20 , Issue.4 , pp. 195-203
    • Gross, D.R.1
  • 5
    • 0014532860 scopus 로고
    • Platelet adhesion induced by fibrinogen adsorbed onto glass
    • Zucker MB, Vroman L. Platelet adhesion induced by fibrinogen adsorbed onto glass. Proc Exp Soc Biol Med 1969; 318-20.
    • (1969) Proc Exp Soc Biol Med , pp. 318-320
    • Zucker, M.B.1    Vroman, L.2
  • 7
    • 0028221317 scopus 로고
    • Surface coating of hydrophilic-hydrophobic block copolymers on a poly(acrylonitrile) heamodialyser reduces platelet adhesion and its transmembrane stimulation
    • Matsuda T, Ito S. Surface coating of hydrophilic-hydrophobic block copolymers on a poly(acrylonitrile) heamodialyser reduces platelet adhesion and its transmembrane stimulation. Biomaterials 1994; 15: 6: 417-22.
    • (1994) Biomaterials , vol.15 , Issue.6 , pp. 417-422
    • Matsuda, T.1    Ito, S.2
  • 8
    • 0000525533 scopus 로고
    • The influence of droplet volume and contact angle on liquid surface tension measurements by axisymmetric drop shape analysis-profile (ADSA-P)
    • Noordmans J, Busscher HJ. The influence of droplet volume and contact angle on liquid surface tension measurements by axisymmetric drop shape analysis-profile (ADSA-P). Colloid Surfaces 1991; 58: 239-49.
    • (1991) Colloid Surfaces , vol.58 , pp. 239-249
    • Noordmans, J.1    Busscher, H.J.2
  • 9
    • 0011720580 scopus 로고
    • Dynamic aspects of contact angle measurements on adsorbed protein layers
    • Van der Scheer A, Smolders CA. Dynamic aspects of contact angle measurements on adsorbed protein layers. J Colloid Interface Sci 1978; 63: 7-15.
    • (1978) J Colloid Interface Sci , vol.63 , pp. 7-15
    • Van Der Scheer, A.1    Smolders, C.A.2
  • 11
    • 0345712670 scopus 로고    scopus 로고
    • Case postale 56, CH1211 Geneva 20, Switzerland
    • International Organization for Standardization. Biological evaluation of medical devices ISO/FDS 10993 (E), Parts 1-16, 1997, Case postale 56, CH1211 Geneva 20, Switzerland.
    • (1997) Biological Evaluation of Medical Devices ISO/FDS 10993 (E) , Issue.PARTS 1-16


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.