-
1
-
-
0027504581
-
Separate acquisition rest thallium-201/ stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT: A clinical validation study
-
Berman DS, Kiat H, Friedman JD, et al. Separate acquisition rest thallium-201/ stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT: a clinical validation study. J Am Coll Cardiol. 1993;22:1455-1464.
-
(1993)
J Am Coll Cardiol
, vol.22
, pp. 1455-1464
-
-
Berman, D.S.1
Kiat, H.2
Friedman, J.D.3
-
2
-
-
0028100009
-
Pharmacologic stress dual-isotope myocardial perfusion single-photon emission computed tomography
-
Matzer L, Kiat H, Wang FP, et al. Pharmacologic stress dual-isotope myocardial perfusion single-photon emission computed tomography. Am Heart J. 1994;128: 1067-1076.
-
(1994)
Am Heart J
, vol.128
, pp. 1067-1076
-
-
Matzer, L.1
Kiat, H.2
Wang, F.P.3
-
3
-
-
0028295782
-
Separate dual-isotope SPECT imaging with thallium-201 and technetium-99m-sestamibi
-
Heo J, Wolmer I, Kegel J, et al. Separate dual-isotope SPECT imaging with thallium-201 and technetium-99m-sestamibi. J Nucl Med. 1994;35:549-553.
-
(1994)
J Nucl Med
, vol.35
, pp. 549-553
-
-
Heo, J.1
Wolmer, I.2
Kegel, J.3
-
4
-
-
0028206634
-
Dual-isotope myocardial imaging: Feasibility, advantages and limitations. Preliminary report on 231 consecutive patients
-
Weinmann P, Foult J, Le Guludec D, et al. Dual-isotope myocardial imaging: feasibility, advantages and limitations. Preliminary report on 231 consecutive patients. Eur J Nucl Med. 1994;21:212-215.
-
(1994)
Eur J Nucl Med
, vol.21
, pp. 212-215
-
-
Weinmann, P.1
Foult, J.2
Le Guludec, D.3
-
5
-
-
0029358311
-
Simultaneous Tc-99m/Tl-201 imaging using energy-based estimation of the spatial distributions of contaminant photons
-
Moore SC, English RJ, Syravanh C, et al. Simultaneous Tc-99m/Tl-201 imaging using energy-based estimation of the spatial distributions of contaminant photons. IEEE Trans Nucl Sci. 1995;42:1189-1195.
-
(1995)
IEEE Trans Nucl Sci
, vol.42
, pp. 1189-1195
-
-
Moore, S.C.1
English, R.J.2
Syravanh, C.3
-
6
-
-
0002549125
-
Experimental and monte carlo characterization of spectral and spatial distributions of lead x-rays
-
Moore SC, Zimmerman RE, Chan KH, et al. Experimental and Monte Carlo characterization of spectral and spatial distributions of lead x-rays [abstract]. J Nucl Med. 1994;35:61P
-
(1994)
J Nucl Med
, vol.35
-
-
Moore, S.C.1
Zimmerman, R.E.2
Chan, K.H.3
-
7
-
-
0345264080
-
99mTc sestamibi dual isotope myocardial perfusion SPECT
-
99mTc sestamibi dual isotope myocardial perfusion SPECT [abstract]. J Nucl Med. 1992;33:854P.
-
(1992)
J Nucl Med
, vol.33
-
-
Kiat, H.1
Germano, G.2
Van Train, K.3
-
8
-
-
0011187035
-
Comparison of separate acquisition dual isotope SPECT including late redistribution imaging with rest/stress Tc-sestamibi SPECT for rest defect size and reversibility pattern
-
Matzer L, Kiat H, Chen M, et al. Comparison of separate acquisition dual isotope SPECT including late redistribution imaging with rest/stress Tc-sestamibi SPECT for rest defect size and reversibility pattern [abstract]. Circulation. 1992;86:1-505.
-
(1992)
Circulation
, vol.86
, pp. 1-505
-
-
Matzer, L.1
Kiat, H.2
Chen, M.3
-
9
-
-
0028218858
-
Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT
-
Kiat H, Germano G, Friedman J, et al. Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT. J Nucl Med 1994;35:542-548.
-
(1994)
J Nucl Med
, vol.35
, pp. 542-548
-
-
Kiat, H.1
Germano, G.2
Friedman, J.3
-
10
-
-
0027493271
-
Cardiac phantom evaluation of simultaneously acquired dual-isotope rest thallium-201/stress technetium-99m dual-isotope cardiac SPECT images
-
Lowe VJ, Greer KL, Hanson MW, Jaszczak RJ, Coleman RE. Cardiac phantom evaluation of simultaneously acquired dual-isotope rest thallium-201/stress technetium-99m dual-isotope cardiac SPECT images. J Nucl Med. 1993;34:1998-2006.
-
(1993)
J Nucl Med
, vol.34
, pp. 1998-2006
-
-
Lowe, V.J.1
Greer, K.L.2
Hanson, M.W.3
Jaszczak, R.J.4
Coleman, R.E.5
-
11
-
-
0027696727
-
Simultaneous thallium-201/technetium-99m dual-isotope cardiac SPECT: Ready for prime time?
-
DePuey EG. Simultaneous thallium-201/technetium-99m dual-isotope cardiac SPECT: ready for prime time? [editorial]. J Nucl Med. 1993;34:2006-2008.
-
(1993)
J Nucl Med
, vol.34
, pp. 2006-2008
-
-
DePuey, E.G.1
-
12
-
-
0005496179
-
Simultaneous SPECT imaging of Tl-201 and Tc-99m using four energy windows
-
Moore SC, Syravanh C, Tow DE. Simultaneous SPECT imaging of Tl-201 and Tc-99m using four energy windows [abstract]. J Nucl Med. 1993;34:188P.
-
(1993)
J Nucl Med
, vol.34
-
-
Moore, S.C.1
Syravanh, C.2
Tow, D.E.3
-
13
-
-
0027426806
-
Radionuclide simultaneous dual-isotope stress myocardial perfusion study using the "three window technique."
-
Yang DC, Ragasa E, Gould L, et al. Radionuclide simultaneous dual-isotope stress myocardial perfusion study using the "three window technique." Clin Nucl Med. 1993;18:852-857.
-
(1993)
Clin Nucl Med
, vol.18
, pp. 852-857
-
-
Yang, D.C.1
Ragasa, E.2
Gould, L.3
-
14
-
-
0026040861
-
A review of cardiac imaging with sestamibi and teboroxime
-
Leppo JA, DePuey EG, Johnson LL. A review of cardiac imaging with sestamibi and teboroxime. J Nucl Med. 1991;32:2012-2022.
-
(1991)
J Nucl Med
, vol.32
, pp. 2012-2022
-
-
Leppo, J.A.1
Depuey, E.G.2
Johnson, L.L.3
-
15
-
-
0025784351
-
Current status of nuclear cardiology techniques
-
Beller GA. Current status of nuclear cardiology techniques. Curr Probl Cardiol. 1991;16:451-535.
-
(1991)
Curr Probl Cardiol
, vol.16
, pp. 451-535
-
-
Beller, G.A.1
-
16
-
-
0026229759
-
The new 99m-Tc myocardial perfusion imaging agents: 99m-Tc sestamibi and 99m-Tc teboroxime
-
Berman DS, Kiat H, Maddahi J. The new 99m-Tc myocardial perfusion imaging agents: 99m-Tc sestamibi and 99m-Tc teboroxime. Circulation. 1991;84:17-21.
-
(1991)
Circulation
, vol.84
, pp. 17-21
-
-
Berman, D.S.1
Kiat, H.2
Maddahi, J.3
-
17
-
-
0026573111
-
Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease
-
Maublant JC, Marcaggi X, Lusson JR, et al. Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease. Am J Cardiol 1992;69:183-187.
-
(1992)
Am J Cardiol
, vol.69
, pp. 183-187
-
-
Maublant, J.C.1
Marcaggi, X.2
Lusson, J.R.3
-
18
-
-
0019416458
-
Agreement in human interpretation of analog thallium myocardial perfusion images
-
Atwood JE, Jensen D, Froelicher V, et al. Agreement in human interpretation of analog thallium myocardial perfusion images. Circulation. 1981;64:601-609.
-
(1981)
Circulation
, vol.64
, pp. 601-609
-
-
Atwood, J.E.1
Jensen, D.2
Froelicher, V.3
-
19
-
-
85069257720
-
Compensation for Tc-99m contamination of Tl-201 images in simultaneous dual-isotope SPECT: Effects of size of scattering medium
-
Moore SC, McIlvain TR, Kijewski MF. Compensation for Tc-99m contamination of Tl-201 images in simultaneous dual-isotope SPECT: effects of size of scattering medium. IEEE Trans Med Imaging. 1995;(suppl):207-211.
-
(1995)
IEEE Trans Med Imaging
, Issue.SUPPL.
, pp. 207-211
-
-
Moore, S.C.1
McIlvain, T.R.2
Kijewski, M.F.3
|