Volumn 37, Issue 3, 1999, Pages 377-380

Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source

Author keywords

Accelerafed motion; Automatic power generating system; Button type pacemaker; Capacitor; Charging characteristic; Discharging characteristic; Energy; Kinetic energy; Leadless pacemaker; Mechano electric energy conversion system

Indexed keywords

CAPACITORS; CHARGING (BATTERIES); ELECTRIC DISCHARGES; KINETIC ENERGY; PACEMAKERS;

EID: 0032993495     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02513315     Document Type: Article
Times cited : (74)

References (14)
  • 4
    • 0344157116 scopus 로고
    • A study of the new energy system for quartz watches (II)-The effective circuit for the system
    • C. E. C.
    • HAYAKAWA, N. (1988): 'A study of the new energy system for quartz watches (II)-The effective circuit for the system', Proc. Congrès Européen de Chronométrie, C. E. C., pp. 81-85
    • (1988) Proc. Congrès Européen de Chronométrie , pp. 81-85
    • Hayakawa, N.1
  • 5
    • 0030745615 scopus 로고    scopus 로고
    • High thresholds may alter end-of-life behavior in a dual chamber pacemaker
    • KRAUS, M., BUCKINGHAM, T. A., and CANDINAS, R. (1997): 'High thresholds may alter end-of-life behavior in a dual chamber pacemaker', Pacing Clin. Electrophysiol., 20, pp. 1691-1697
    • (1997) Pacing Clin. Electrophysiol. , vol.20 , pp. 1691-1697
    • Kraus, M.1    Buckingham, T.A.2    Candinas, R.3
  • 6
    • 0030989414 scopus 로고    scopus 로고
    • Useful applications and limits of battery powered implants in functional electrical stimulations
    • LANMULLER, H., BIJAK, M., MAYR, W., RAFOLT, D., SAUERMANN, S., and THOMA, H. (1997): 'Useful applications and limits of battery powered implants in functional electrical stimulations', Artif. Organs, 21, pp. 210-212
    • (1997) Artif. Organs , vol.21 , pp. 210-212
    • Lanmuller, H.1    Bijak, M.2    Mayr, W.3    Rafolt, D.4    Sauermann, S.5    Thoma, H.6
  • 8
    • 0026512433 scopus 로고
    • The electrode-tissue interface: The revolutionary role of steroid elution
    • MOND, H. G., and STOKES, K. B. (1992): 'The electrode-tissue interface: The revolutionary role of steroid elution', PACE, 15, pp. 95-107
    • (1992) PACE , vol.15 , pp. 95-107
    • Mond, H.G.1    Stokes, K.B.2
  • 9
    • 0016127163 scopus 로고
    • The automatic thresholds tracking pacemaker
    • PRESTON, T. A., and BOWERS, D. L. (1974): 'The automatic thresholds tracking pacemaker', Med. Instrum., 8, pp. 322-325
    • (1974) Med. Instrum. , vol.8 , pp. 322-325
    • Preston, T.A.1    Bowers, D.L.2
  • 10
    • 84958923678 scopus 로고
    • Longevity and pacemaker power sources
    • Springer-Verlag, Chapter 5
    • SCHALDACH, M., and FURMAN, S. (Ed.) (1975): 'Longevity and pacemaker power sources', in 'Advances in pacemaker technology' (Springer-Verlag), Chapter 5
    • (1975) Advances in Pacemaker Technology
    • Schaldach, M.1    Furman, S.2
  • 11
    • 0027958217 scopus 로고
    • Influence of internal current and pacing current on pacemaker longevity
    • SCHUCHERT, A., and KUCK, K. H. (1994): 'Influence of internal current and pacing current on pacemaker longevity', Pacing Clin. Electrophysiol., 17,(1), pp. 13-16
    • (1994) Pacing Clin. Electrophysiol. , vol.17 , Issue.1 , pp. 13-16
    • Schuchert, A.1    Kuck, K.H.2
  • 13
    • 0344157115 scopus 로고    scopus 로고
    • Batteries for implantable medical devices
    • TOYOSHIMA, T. (1997): 'Batteries for implantable medical devices', Clin. Eng., 8, pp. 734-741
    • (1997) Clin. Eng. , vol.8 , pp. 734-741
    • Toyoshima, T.1
  • 14
    • 0344157114 scopus 로고
    • A study of the new energy system for quartz watches
    • La Chaux-de-Fonds
    • YASUKAWA, N., and NAGAO, S. (1986): 'A study of the new energy system for quartz watches', Proc. Congrès de Chronométrie, La Chaux-de-Fonds, pp. 15-18
    • (1986) Proc. Congrès de Chronométrie , pp. 15-18
    • Yasukawa, N.1    Nagao, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.