메뉴 건너뛰기




Volumn 143, Issue 1, 1999, Pages 171-175

Immunoscintigraphy of atherosclerotic uncomplicated lesions in vivo with a monoclonal antibody against D-dimers of insoluble fibrin

Author keywords

Atherosclerotic plaque; Monoclonal antifibrin antibodies; Scintigraphy

Indexed keywords

FIBRIN ANTIBODY; IMMUNOGLOBULIN F(AB')2 FRAGMENT; MONOCLONAL ANTIBODY; PERTECHNETIC ACID TC 99M;

EID: 0032989390     PISSN: 00219150     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9150(98)00272-X     Document Type: Article
Times cited : (10)

References (16)
  • 1
    • 0026746480 scopus 로고
    • Anti D dimer monoclonal antibodies: A possible scintigraphic agent for immunodetection of thrombi
    • Scopinaro F., Di Loreto M., Banci M. et al. Anti D dimer monoclonal antibodies: a possible scintigraphic agent for immunodetection of thrombi. Nucl. Med. Commun. 13:1992;723-729.
    • (1992) Nucl. Med. Commun. , vol.13 , pp. 723-729
    • Scopinaro, F.1    Di Loreto, M.2    Banci, M.3
  • 2
    • 0026674509 scopus 로고
    • Evaluation of thrombus detection in a rabbit model using a technetium-99m-labeled antifibrin monoclonal antibody
    • Lee F.T., Milner L.J., Boniface G.R. Evaluation of thrombus detection in a rabbit model using a technetium-99m-labeled antifibrin monoclonal antibody. Immunol. Cell. Biol. 70:1992;173-179.
    • (1992) Immunol. Cell. Biol. , vol.70 , pp. 173-179
    • Lee, F.T.1    Milner, L.J.2    Boniface, G.R.3
  • 3
    • 0024555917 scopus 로고
    • Binding properties of monoclonal antibodies against human fragment D-dimer of cross-linked fibrin to human plasma clots in an in vivo model in rabbits
    • Holvoet P., Stassen J.M., Hashimoto Y., Spriggs D., Devos P., Collen D. Binding properties of monoclonal antibodies against human fragment D-dimer of cross-linked fibrin to human plasma clots in an in vivo model in rabbits. Thromb. Haemost. 61:1989;307-313.
    • (1989) Thromb. Haemost. , vol.61 , pp. 307-313
    • Holvoet, P.1    Stassen, J.M.2    Hashimoto, Y.3    Spriggs, D.4    Devos, P.5    Collen, D.6
  • 4
    • 0027297755 scopus 로고
    • Immunodetection of human atherosclerotic plaque with 125I-labeled monoclonal antifibrin antibodies
    • Greco C., Di Loreto M., Ciavolella M. et al. Immunodetection of human atherosclerotic plaque with 125I-labeled monoclonal antifibrin antibodies. Atherosclerosis. 100:1993;133-139.
    • (1993) Atherosclerosis , vol.100 , pp. 133-139
    • Greco, C.1    Di Loreto, M.2    Ciavolella, M.3
  • 5
    • 0022409569 scopus 로고
    • An interactive computer program for the determination of the binding constant of monoclonal antibodies by non linear regression analysis of radioimmunoassay data
    • Antony G., Mariani M. An interactive computer program for the determination of the binding constant of monoclonal antibodies by non linear regression analysis of radioimmunoassay data. J. Immun. Method. 83:1985;61.
    • (1985) J. Immun. Method. , vol.83 , pp. 61
    • Antony, G.1    Mariani, M.2
  • 6
    • 0025869608 scopus 로고
    • MRC European Carotid Surgery Trial: Interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis
    • MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis. Lancet. 337:1991;1235-1243.
    • (1991) Lancet , vol.337 , pp. 1235-1243
  • 7
    • 0025734372 scopus 로고
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. New. Engl. J. Med. 325:1991;445-453.
    • (1991) New. Engl. J. Med. , vol.325 , pp. 445-453
  • 8
    • 0031053264 scopus 로고    scopus 로고
    • Carotid endarterectomy in patients with recently symptomatic moderate (30-69%) carotid stenosis: No overall benefit
    • Rothwell P.M., Warlow C.P. Carotid endarterectomy in patients with recently symptomatic moderate (30-69%) carotid stenosis: no overall benefit. Eur. Heart. J. 18:1997;355-356.
    • (1997) Eur. Heart. J. , vol.18 , pp. 355-356
    • Rothwell, P.M.1    Warlow, C.P.2
  • 10
    • 0024801308 scopus 로고
    • Detection of experimental atherosclerosis with indium-111 radiolabelled hematoporphyrin derivative
    • Palac R.T., Gray L.L., Turner F.E., Brown P.H., Malinow M.R., Demots H. Detection of experimental atherosclerosis with indium-111 radiolabelled hematoporphyrin derivative. Nucl. Med. Commun. 10:1989;841-848.
    • (1989) Nucl. Med. Commun. , vol.10 , pp. 841-848
    • Palac, R.T.1    Gray, L.L.2    Turner, F.E.3    Brown, P.H.4    Malinow, M.R.5    Demots, H.6
  • 11
    • 0023885889 scopus 로고
    • Iodine-131-labeled fibronectin: Potential agent for imaging atherosclerotic lesion and thrombus
    • Uehara A., Isaka Y., Hashikawa K. et al. Iodine-131-labeled fibronectin: potential agent for imaging atherosclerotic lesion and thrombus. J. Nucl. Med. 29:1988;1264-1269.
    • (1988) J. Nucl. Med. , vol.29 , pp. 1264-1269
    • Uehara, A.1    Isaka, Y.2    Hashikawa, K.3
  • 12
    • 0024380368 scopus 로고
    • Radionuclide imaging of experimental atherosclerosis with nonspecific polyclonal immunoglohulin G
    • Fischman A.J., Rubin R.H., Khaw B.A. et al. Radionuclide imaging of experimental atherosclerosis with nonspecific polyclonal immunoglohulin G. J. Nucl. Med. 30:1989;1095-1101.
    • (1989) J. Nucl. Med. , vol.30 , pp. 1095-1101
    • Fischman, A.J.1    Rubin, R.H.2    Khaw, B.A.3
  • 13
    • 0025964944 scopus 로고
    • In vivo technetium-99m S12 antibody imaging of platelet A-granules in rabbit endothelial neointimal proliferation after angioplasty
    • Miller D.D., Boulet A.J., Tio F.O. et al. In vivo technetium-99m S12 antibody imaging of platelet A-granules in rabbit endothelial neointimal proliferation after angioplasty. Circulation. 83:1991;224-230.
    • (1991) Circulation , vol.83 , pp. 224-230
    • Miller, D.D.1    Boulet, A.J.2    Tio, F.O.3
  • 14
    • 0028099441 scopus 로고
    • Imaging arterial thrombosis: Comparison of technetium-99m-labeled monoclonal antifibrin antibodies and indium-111-platelets
    • Stratton J.R., Cerqueira M.D., Dewhurst T.A., Kohler T.R. Imaging arterial thrombosis: comparison of technetium-99m-labeled monoclonal antifibrin antibodies and indium-111-platelets. J. Nucl. Med. 35:1994;1731-1737.
    • (1994) J. Nucl. Med. , vol.35 , pp. 1731-1737
    • Stratton, J.R.1    Cerqueira, M.D.2    Dewhurst, T.A.3    Kohler, T.R.4
  • 15
    • 0028140514 scopus 로고
    • Detection of deep venous thrombi and pulmonary embolus with technetium-99m-DD-3B6/22 anti-fibrin monoclonal antibody Fab′ fragment
    • Bautovich G., Angelides S., Lee F.T. et al. Detection of deep venous thrombi and pulmonary embolus with technetium-99m-DD-3B6/22 anti-fibrin monoclonal antibody Fab′ fragment. J. Nucl. Med. 35:1994;195-202.
    • (1994) J. Nucl. Med. , vol.35 , pp. 195-202
    • Bautovich, G.1    Angelides, S.2    Lee, F.T.3
  • 16
    • 0345369194 scopus 로고    scopus 로고
    • Immunoscintigraphy of venous thrombi: Clinical effectiveness of a new antifibrin D-dimer monoclonal antibody
    • in press
    • Ciavolella M, Tavolaro R, Di Loreto M, et al. Immunoscintigraphy of venous thrombi: clinical effectiveness of a new antifibrin D-dimer monoclonal antibody. Angiology 1998 (in press).
    • (1998) Angiology
    • Ciavolella, M.1    Tavolaro, R.2    Di Loreto, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.