-
1
-
-
0022732465
-
Cerebrospinal impedance response to induced epiteptic activity
-
1. Miller, G. E. & T. L. Gerber. 1986. Cerebrospinal impedance response to induced epiteptic activity. IEEE Trans. Biomed. Eng. 33: 626-632.
-
(1986)
IEEE Trans. Biomed. Eng.
, vol.33
, pp. 626-632
-
-
Miller, G.E.1
Gerber, T.L.2
-
2
-
-
0029239605
-
Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models
-
2. Wang, L. & R. Patterson. 1995. Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models. IEEE Trans. Biomed. Eng. 42: 141-148.
-
(1995)
IEEE Trans. Biomed. Eng.
, vol.42
, pp. 141-148
-
-
Wang, L.1
Patterson, R.2
-
3
-
-
0024246081
-
Origins of the impedance change in impedance cardiography by a three-dimensional finite element model
-
3. Kim, D. W. et al. 1988. Origins of the impedance change in impedance cardiography by a three-dimensional finite element model. IEEE Trans. Biomed. Eng. 35: 993-1000.
-
(1988)
IEEE Trans. Biomed. Eng.
, vol.35
, pp. 993-1000
-
-
Kim, D.W.1
-
4
-
-
0029079227
-
Examination of impedance cardiography properties - FEM model studies
-
4. Wtorek, J. & A. Polinski. 1995. Examination of impedance cardiography properties - FEM model studies. Biomed. Sci. Instrum. 31: 77-82.
-
(1995)
Biomed. Sci. Instrum.
, vol.31
, pp. 77-82
-
-
Wtorek, J.1
Polinski, A.2
-
5
-
-
85047680118
-
Investigation of the origin of the impedance cardiogram by means of exchange transfusion with stroma free haemoglobin solution in the dog
-
5. Visser, K. R., R. Lamberts & W. G. Zulstra. 1990. Investigation of the origin of the impedance cardiogram by means of exchange transfusion with stroma free haemoglobin solution in the dog. Cardiovasc. Res. 24: 24-32.
-
(1990)
Cardiovasc. Res.
, vol.24
, pp. 24-32
-
-
Visser, K.R.1
Lamberts, R.2
Zulstra, W.G.3
-
6
-
-
0029553313
-
Electric field plethysmography signals of the human thorax as determined by a 2-D FE-model
-
6. Nopp, P. et al. 1995. Electric field plethysmography signals of the human thorax as determined by a 2-D FE-model. Med. Prog. Technol. 21: 135-145.
-
(1995)
Med. Prog. Technol.
, vol.21
, pp. 135-145
-
-
Nopp, P.1
-
7
-
-
0028485943
-
Cardiac and respiratory related electrical impedance changes in the human thorax
-
7. Brown, B. H., et al. 1994. Cardiac and respiratory related electrical impedance changes in the human thorax. IEEE Trans. Biomcd. Eng. 41: 729-734.
-
(1994)
IEEE Trans. Biomcd. Eng.
, vol.41
, pp. 729-734
-
-
Brown, B.H.1
-
9
-
-
0014986362
-
An application of electrocardiographic lead theory to impedance plethysmography
-
9. Geselowitz, D. B. 1971. An application of electrocardiographic lead theory to impedance plethysmography. IEEE Trans. Biomed. Eng. 18: 38-41.
-
(1971)
IEEE Trans. Biomed. Eng.
, vol.18
, pp. 38-41
-
-
Geselowitz, D.B.1
-
12
-
-
0029257413
-
Validation of a detailed computer model for the electric fields in the brain
-
12. Laarne, P. et al. 1995. Validation of a detailed computer model for the electric fields in the brain. J. Med. Eng. Technol. 19; 84-87.
-
(1995)
J. Med. Eng. Technol.
, vol.19
, pp. 84-87
-
-
Laarne, P.1
-
13
-
-
0033083076
-
A software implementation for detailed volume conductor modeling in electrophysiology using finite difference method
-
13. Kauppinen, P. et al. 1999. A software implementation for detailed volume conductor modeling in electrophysiology using finite difference method. Comput. Methods Programs Biomed. 58: 191-203.
-
(1999)
Comput. Methods Programs Biomed.
, vol.58
, pp. 191-203
-
-
Kauppinen, P.1
-
14
-
-
0032078882
-
Detailed model of the thorax as a volume conductor based on the Visible Human Man data
-
14. Kauppinen, P. et al. 1998. Detailed model of the thorax as a volume conductor based on the Visible Human Man data. J. Med. Eng. Technol. 22: 126-133.
-
(1998)
J. Med. Eng. Technol.
, vol.22
, pp. 126-133
-
-
Kauppinen, P.1
|