메뉴 건너뛰기




Volumn 11, Issue 2, 1999, Pages 132-135

Systolic pressure variation in hemodynamic monitoring after severe blast injury

Author keywords

Arterial blood pressure; Blast injury; Monitoring: hemodynamics; Monitoring: invasive blood pressure; Systolic pressure variation; Transesophageal echocardiography; Trauma

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL VENTILATION; BLAST INJURY; BLOOD PRESSURE MONITORING; CASE REPORT; FLUID THERAPY; HUMAN; HYPOVOLEMIA; PRIORITY JOURNAL; SYSTOLIC BLOOD PRESSURE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 0032979652     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0952-8180(99)00006-9     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0023853276 scopus 로고
    • Pulmonary effects of crystalloid and colloid resuscitation from hemorrhagic shock in the presence of oleic acid-induced pulmonary capillary injury in the dog
    • Pearl R.G., Halperin B.D., Mihm F.G., Rosenthal M.H. Pulmonary effects of crystalloid and colloid resuscitation from hemorrhagic shock in the presence of oleic acid-induced pulmonary capillary injury in the dog. Anesthesiology. 68:1988;12-20.
    • (1988) Anesthesiology , vol.68 , pp. 12-20
    • Pearl, R.G.1    Halperin, B.D.2    Mihm, F.G.3    Rosenthal, M.H.4
  • 2
    • 0024592862 scopus 로고
    • Primary blast injury after a bomb explosion in a civilian bus
    • Katz E., Ofek B., Adler J., Abramowitz H.B., Krausz M.M. Primary blast injury after a bomb explosion in a civilian bus. Ann Surg. 209:1989;484-488.
    • (1989) Ann Surg , vol.209 , pp. 484-488
    • Katz, E.1    Ofek, B.2    Adler, J.3    Abramowitz, H.B.4    Krausz, M.M.5
  • 3
    • 0030923118 scopus 로고    scopus 로고
    • Management of primary blast injury
    • Argyros G.J. Management of primary blast injury. Toxicology. 121:1997;105-115.
    • (1997) Toxicology , vol.121 , pp. 105-115
    • Argyros, G.J.1
  • 4
    • 0025343949 scopus 로고
    • Estimation of left ventricular volume and ejection fraction by two-dimensional transesophageal echocardiography: Comparison of short axis imaging and simultaneous radionuclide angiography
    • Clements F.M., Harpole D.H., Quill T., Jones R.H., McCann R.L. Estimation of left ventricular volume and ejection fraction by two-dimensional transesophageal echocardiography comparison of short axis imaging and simultaneous radionuclide angiography . Br J Anaesth. 64:1990;331-336.
    • (1990) Br J Anaesth , vol.64 , pp. 331-336
    • Clements, F.M.1    Harpole, D.H.2    Quill, T.3    Jones, R.H.4    McCann, R.L.5
  • 5
    • 0028956145 scopus 로고
    • Evaluation of transesophageal echocardiography as a diagnostic and therapeutic aid in a critical care setting
    • Poelaert J.I., Trouerbach J., De Buyzere M., Everaert J., Colardyn F.A. Evaluation of transesophageal echocardiography as a diagnostic and therapeutic aid in a critical care setting. Chest. 107:1995;774-779.
    • (1995) Chest , vol.107 , pp. 774-779
    • Poelaert, J.I.1    Trouerbach, J.2    De Buyzere, M.3    Everaert, J.4    Colardyn, F.A.5
  • 6
    • 0027954235 scopus 로고
    • The role of echocardiography in blunt chest trauma: A transthoracic and transesophageal echocardiographic study
    • Karalis D.G., Victor M.F., Davis G.A., et al. The role of echocardiography in blunt chest trauma a transthoracic and transesophageal echocardiographic study . J Trauma. 36:1994;53-58.
    • (1994) J Trauma , vol.36 , pp. 53-58
    • Karalis, D.G.1    Victor, M.F.2    Davis, G.A.3
  • 7
    • 0023605206 scopus 로고
    • Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage
    • Perel A., Pizov R., Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 67:1987;498-502.
    • (1987) Anesthesiology , vol.67 , pp. 498-502
    • Perel, A.1    Pizov, R.2    Cotev, S.3
  • 8
    • 0025697098 scopus 로고
    • The use of systolic pressure variation in hemodynamic monitoring during deliberate hypotension in spine surgery
    • Pizov R., Segal E., Kaplan L., Floman Y., Perel A. The use of systolic pressure variation in hemodynamic monitoring during deliberate hypotension in spine surgery. J Clin Anesth. 2:1990;96-100.
    • (1990) J Clin Anesth , vol.2 , pp. 96-100
    • Pizov, R.1    Segal, E.2    Kaplan, L.3    Floman, Y.4    Perel, A.5
  • 9
    • 0029786702 scopus 로고    scopus 로고
    • Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform
    • Pizov R., Cohen M., Weiss Y.G., Segal E., Cotev S., Perel A. Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform. Crit Care Med. 24:1996;1381-1387.
    • (1996) Crit Care Med , vol.24 , pp. 1381-1387
    • Pizov, R.1    Cohen, M.2    Weiss, Y.G.3    Segal, E.4    Cotev, S.5    Perel, A.6
  • 10
    • 0028084525 scopus 로고
    • A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery
    • Coriat P., Vrillon M., Perel A., et al. A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery. Anesth Analg. 78:1994;46-53.
    • (1994) Anesth Analg , vol.78 , pp. 46-53
    • Coriat, P.1    Vrillon, M.2    Perel, A.3
  • 11
    • 0024600063 scopus 로고
    • The arterial pressure waveform during acute ventricular failure and synchronized external chest compression
    • Pizov R., Ya'ari Y., Perel A. The arterial pressure waveform during acute ventricular failure and synchronized external chest compression. Anesth Analg. 68:1989;150-156.
    • (1989) Anesth Analg , vol.68 , pp. 150-156
    • Pizov, R.1    Ya'Ari, Y.2    Perel, A.3
  • 12
    • 0026068619 scopus 로고
    • Estimated left ventricular filling pressure during positive end-expiratory pressure in humans
    • Pinsky M., Vincent J.L., DeSmet J.M. Estimated left ventricular filling pressure during positive end-expiratory pressure in humans. Am Rev Respir Dis. 143:1991;25-31.
    • (1991) Am Rev Respir Dis , vol.143 , pp. 25-31
    • Pinsky, M.1    Vincent, J.L.2    Desmet, J.M.3
  • 13
    • 0018601944 scopus 로고
    • Lung expansion, airway pressure transmission, and positive end-expiratory pressure
    • Chapin J.C., Downs J.B., Douglas M.E., Murphy E.J. Lung expansion, airway pressure transmission, and positive end-expiratory pressure. Arch Surg. 114:1979;1193-1197.
    • (1979) Arch Surg , vol.114 , pp. 1193-1197
    • Chapin, J.C.1    Downs, J.B.2    Douglas, M.E.3    Murphy, E.J.4
  • 14
    • 0030740463 scopus 로고    scopus 로고
    • Haemodynamic changes induced by two I:E ratios: A transesophageal echocardiographic study
    • Vedrinne J.M., Duperret S., Decaillot F., Gratadour P., Motin J. Haemodynamic changes induced by two I:E ratios a transesophageal echocardiographic study . Can J Anaesth. 44:1997;354-359.
    • (1997) Can J Anaesth , vol.44 , pp. 354-359
    • Vedrinne, J.M.1    Duperret, S.2    Decaillot, F.3    Gratadour, P.4    Motin, J.5
  • 17
    • 0030048288 scopus 로고    scopus 로고
    • Systolic pressure variation - A way to recognize dynamic hyperinflation
    • [Letter]
    • Perel A., Segal E. Systolic pressure variation - a way to recognize dynamic hyperinflation. Br J Anaesth. 76:1996;168-169. [Letter].
    • (1996) Br J Anaesth , vol.76 , pp. 168-169
    • Perel, A.1    Segal, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.