메뉴 건너뛰기




Volumn 13, Issue 3, 1999, Pages 253-257

Continuous arterial blood gas monitoring during bilateral sequential lung transplantation

Author keywords

Anesthesia; Blood gas sensors; End tidal; Lung transplantation; Monitoring; Surgery

Indexed keywords

ACID BASE BALANCE; ADULT; ANESTHESIOLOGICAL TECHNIQUES; ARTERIAL GAS; ARTICLE; BLOOD GAS ANALYSIS; FEMALE; GAS EXCHANGE; HUMAN; LUNG TRANSPLANTATION; MALE; PATIENT MONITORING; PRIORITY JOURNAL; SENSOR;

EID: 0032979281     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(99)90259-8     Document Type: Article
Times cited : (8)

References (23)
  • 1
    • 0023764852 scopus 로고
    • Isolated lung transplantation: A review of problems and a guide to anaesthesia
    • Conacher ID: Isolated lung transplantation: A review of problems and a guide to anaesthesia. Br J Anaesth 61:468-474, 1988
    • (1988) Br J Anaesth , vol.61 , pp. 468-474
    • Conacher, I.D.1
  • 2
    • 0025299139 scopus 로고
    • Anesthetic considerations for patients undergoing double-lung transplantation
    • Gayes JM, Giron L, Nissen MD: Anesthetic considerations for patients undergoing double-lung transplantation. J Cardiothorac Vasc Anesth 4:486-498, 1990
    • (1990) J Cardiothorac Vasc Anesth , vol.4 , pp. 486-498
    • Gayes, J.M.1    Giron, L.2    Nissen, M.D.3
  • 3
    • 0026749686 scopus 로고
    • Anesthesia for bilateral lung transplantation without cardiopulmonary bypass: Initial experience and review of intraoperative problems
    • Raffin L, Michel-Cherqui M, Sperandio M: Anesthesia for bilateral lung transplantation without cardiopulmonary bypass: Initial experience and review of intraoperative problems. J Cardiothorac Vasc Anesth 6:409-417, 1992
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 409-417
    • Raffin, L.1    Michel-Cherqui, M.2    Sperandio, M.3
  • 4
    • 0030949893 scopus 로고    scopus 로고
    • Anesthesia for bilateral sequential lung transplantation: Experience of 64 cases
    • Myles PS, Weeks AM, Buckland MR: Anesthesia for bilateral sequential lung transplantation: Experience of 64 cases. J Cardiothorac Vasc Anesth 11: 177-183, 1997
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 177-183
    • Myles, P.S.1    Weeks, A.M.2    Buckland, M.R.3
  • 5
    • 0031115937 scopus 로고    scopus 로고
    • Lung transplantation: Historical perspectives, current concepts, and anesthetic considerations
    • Bracken CA, Gurkowski MA, Naples JJ: Lung transplantation: Historical perspectives, current concepts, and anesthetic considerations. J Cardiothorac Vasc Anesth 11:220-241, 1997
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 220-241
    • Bracken, C.A.1    Gurkowski, M.A.2    Naples, J.J.3
  • 6
    • 0025170596 scopus 로고
    • Pulse oximetry failure thresholds in hypotension and vasoconstriction
    • Severinghaus JW, Spellman MJ: Pulse oximetry failure thresholds in hypotension and vasoconstriction. Anesthesiology 73:532-537, 1990
    • (1990) Anesthesiology , vol.73 , pp. 532-537
    • Severinghaus, J.W.1    Spellman, M.J.2
  • 7
    • 0026024572 scopus 로고
    • Potential errors in pulse oximetry. I. Pulse oximetry evaluation
    • Ralston AC, Webb RK, Runciman WB: Potential errors in pulse oximetry. I. Pulse oximetry evaluation. Anaesthesia 46:202-206, 1991
    • (1991) Anaesthesia , vol.46 , pp. 202-206
    • Ralston, A.C.1    Webb, R.K.2    Runciman, W.B.3
  • 8
    • 0026100834 scopus 로고
    • Potential errors in pulse oximetry. III. Pulse oximetry evaluation
    • Ralston AC, Webb RK, Runciman WB: Potential errors in pulse oximetry. III. Pulse oximetry evaluation. Anaesthesia 46:291-295, 1991
    • (1991) Anaesthesia , vol.46 , pp. 291-295
    • Ralston, A.C.1    Webb, R.K.2    Runciman, W.B.3
  • 9
    • 0028214567 scopus 로고
    • A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation
    • Venkatesh B, Clutton-Brock TH, Hendry SP: A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation. Crit Care Med 22:588-594, 1994
    • (1994) Crit Care Med , vol.22 , pp. 588-594
    • Venkatesh, B.1    Clutton-Brock, T.H.2    Hendry, S.P.3
  • 10
    • 0026759289 scopus 로고
    • Alpha 1-antitrypsin deficiency: Circulatory arrest following induction of anaesthesia
    • Myles PS, Weeks AM: Alpha 1-antitrypsin deficiency: Circulatory arrest following induction of anaesthesia. Anaesth Intens Care 20:358-362, 1992
    • (1992) Anaesth Intens Care , vol.20 , pp. 358-362
    • Myles, P.S.1    Weeks, A.M.2
  • 11
    • 0028811139 scopus 로고
    • Avoidance of cardiopulmonary bypass during bilateral sequential lung transplantation using inhaled nitric oxide
    • Myles PS, Venema H: Avoidance of cardiopulmonary bypass during bilateral sequential lung transplantation using inhaled nitric oxide. J Cardiothorac Vasc Anesth 9:571-574, 1995
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 571-574
    • Myles, P.S.1    Venema, H.2
  • 12
    • 0027252656 scopus 로고
    • Deliberate hypoventilation in a patient with air trapping during lung transplantation
    • Quinlan JJ, Buffington CW: Deliberate hypoventilation in a patient with air trapping during lung transplantation. Anesthesiology 78:1177-1180, 1993
    • (1993) Anesthesiology , vol.78 , pp. 1177-1180
    • Quinlan, J.J.1    Buffington, C.W.2
  • 13
    • 0029933335 scopus 로고    scopus 로고
    • Problems in the management of the airway during anesthesia for bilateral sequential lung transplantation performed without cardiopulmonary bypass
    • Horan BF, Cutfield GR, Davies IM: Problems in the management of the airway during anesthesia for bilateral sequential lung transplantation performed without cardiopulmonary bypass. J Cardiothorac Vasc Anesth 10:387-390, 1996
    • (1996) J Cardiothorac Vasc Anesth , vol.10 , pp. 387-390
    • Horan, B.F.1    Cutfield, G.R.2    Davies, I.M.3
  • 14
    • 0031048222 scopus 로고    scopus 로고
    • Diagnosis and management of dynamic hyperinflation during lung transplantation
    • Myles PS, Ryder IG, Weeks AM: Diagnosis and management of dynamic hyperinflation during lung transplantation. J Cardiothorac Vasc Anesth 111:100-104, 1997
    • (1997) J Cardiothorac Vasc Anesth , vol.111 , pp. 100-104
    • Myles, P.S.1    Ryder, I.G.2    Weeks, A.M.3
  • 15
    • 2842516309 scopus 로고
    • Continuous blood gas monitoring during lung transplantation
    • Groh J, Haller M, Kilger E, et al: Continuous blood gas monitoring during lung transplantation. Anesthesiology 81:A617, 1994
    • (1994) Anesthesiology , vol.81
    • Groh, J.1    Haller, M.2    Kilger, E.3
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310, 1986
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0028927937 scopus 로고
    • Calculating correlation coefficients with repeated observations: Part 2 - Correlation between subjects
    • Bland JM, Altman DG: Calculating correlation coefficients with repeated observations: Part 2 - Correlation between subjects. BMJ 310:633-634, 1995
    • (1995) BMJ , vol.310 , pp. 633-634
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0025198394 scopus 로고
    • 2 difference during cardiothoracic surgery
    • 2 difference during cardiothoracic surgery. J Cardiothorac Vasc Anesth 4: 105-117, 1990
    • (1990) J Cardiothorac Vasc Anesth , vol.4 , pp. 105-117
    • Fletcher, R.1
  • 21
    • 0028092781 scopus 로고
    • Permissive hypercapnic ventilation
    • Tuxen DV: Permissive hypercapnic ventilation. Am J Respir Crit Care Med 150:870-874, 1994
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 870-874
    • Tuxen, D.V.1
  • 22
    • 0030088510 scopus 로고    scopus 로고
    • Pro: Is continuous intra-arterial blood gas and pH monitoring justifiable?
    • Gilbert HC, Vender JS: Pro: Is continuous intra-arterial blood gas and pH monitoring justifiable? J Clin Monit 12:179-181, 1996
    • (1996) J Clin Monit , vol.12 , pp. 179-181
    • Gilbert, H.C.1    Vender, J.S.2
  • 23
    • 0030088509 scopus 로고    scopus 로고
    • Con: Is continuous intra-arterial blood gas and pH monitoring justifiable?
    • Hoffer JL, Norfleet EA: Con: Is continuous intra-arterial blood gas and pH monitoring justifiable? J Clin Monit 12:183-189, 1996
    • (1996) J Clin Monit , vol.12 , pp. 183-189
    • Hoffer, J.L.1    Norfleet, E.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.