메뉴 건너뛰기




Volumn 9, Issue 1, 1999, Pages 15-18

Diagnostic yield of a 1-MHz transducer in evaluation of the basal cerebral arteries

Author keywords

Brain; Cerebral arteries; Transcranial Doppler sonography; Ultrasound

Indexed keywords

ADULT; AGED; ANTERIOR CEREBRAL ARTERY; ARTICLE; BLOOD FLOW VELOCITY; CEREBROVASCULAR DISEASE; CLINICAL ARTICLE; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; FEMALE; HUMAN; IMAGE QUALITY; MALE; MIDDLE CEREBRAL ARTERY; POSTERIOR CEREBRAL ARTERY; TEMPORAL BONE; ULTRASOUND TRANSDUCER; BRAIN ARTERY; DIAGNOSTIC VALUE; FLOW RATE; FREQUENCY;

EID: 0032961308     PISSN: 10512284     EISSN: None     Source Type: Journal    
DOI: 10.1111/jon19999115     Document Type: Article
Times cited : (6)

References (12)
  • 1
    • 0023956861 scopus 로고
    • A reason for failure to obtain transcranial Doppler flow signals. Hyperostosis of the skull
    • Bruno A, Biller J, Silvidi JA. A reason for failure to obtain transcranial Doppler flow signals. Hyperostosis of the skull. Stroke 1988;19(2):274
    • (1988) Stroke , vol.19 , Issue.2 , pp. 274
    • Bruno, A.1    Biller, J.2    Silvidi, J.A.3
  • 2
    • 0017225613 scopus 로고
    • Skull thickness of black and white races
    • Ross MD, Lee KA, Castle WM. Skull thickness of black and white races. S Afr Med J 1976;50(16):635-638
    • (1976) S Afr Med J , vol.50 , Issue.16 , pp. 635-638
    • Ross, M.D.1    Lee, K.A.2    Castle, W.M.3
  • 3
    • 0027182160 scopus 로고
    • Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography
    • Itoh T, Matsumoto M, Handa N, et al. Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography. Stroke 1993;24(8):1192-1195
    • (1993) Stroke , vol.24 , Issue.8 , pp. 1192-1195
    • Itoh, T.1    Matsumoto, M.2    Handa, N.3
  • 4
    • 0026487422 scopus 로고
    • Transcranial pulsed Doppler. Problems posed by the temporal window
    • Boespflug O, Chun Feng L. Transcranial pulsed Doppler. Problems posed by the temporal window. J Mal Vasc 1992;17(2):112-115
    • (1992) J Mal Vasc , vol.17 , Issue.2 , pp. 112-115
    • Boespflug, O.1    Chun Feng, L.2
  • 5
    • 0026504199 scopus 로고
    • Assessment of the rate of successful transcranial Doppler recording through the temporal windows in Japanese with special reference to aging and sex
    • Hashimoto H, Etani H, Naka M, et al. Assessment of the rate of successful transcranial Doppler recording through the temporal windows in Japanese with special reference to aging and sex. Nippon Ronen Igakkai Zasshi 1992;29(2):119-122
    • (1992) Nippon Ronen Igakkai Zasshi , vol.29 , Issue.2 , pp. 119-122
    • Hashimoto, H.1    Etani, H.2    Naka, M.3
  • 6
    • 0030930056 scopus 로고    scopus 로고
    • Technical limits in transcranial Doppler recording: Inadequate acoustic windows
    • Marinoni M, Ginanneschi A, Forleo P, Amaducci L. Technical limits in transcranial Doppler recording: inadequate acoustic windows. Ultrasound Med Biol 1997;23(8):1275-1277
    • (1997) Ultrasound Med Biol , vol.23 , Issue.8 , pp. 1275-1277
    • Marinoni, M.1    Ginanneschi, A.2    Forleo, P.3    Amaducci, L.4
  • 7
    • 0023607437 scopus 로고
    • Evaluation of cerebrovascular disease by combined extracranial and transcranial Doppler sonography. Experience in 1,039 patients
    • Grolimund P, Seiler RW, Aaslid R, et al. Evaluation of cerebrovascular disease by combined extracranial and transcranial Doppler sonography. Experience in 1,039 patients. Stroke 1987;18(6):1018-1024
    • (1987) Stroke , vol.18 , Issue.6 , pp. 1018-1024
    • Grolimund, P.1    Seiler, R.W.2    Aaslid, R.3
  • 8
    • 0031894957 scopus 로고    scopus 로고
    • Influence of a transducer frequency on Doppler microembolic signals in an in-vitro model
    • Georgiadis D, Wenzel A, Zerkowski HR, et al. Influence of a transducer frequency on Doppler microembolic signals in an in-vitro model. Neurol Res 1998;20(3):198-200
    • (1998) Neurol Res , vol.20 , Issue.3 , pp. 198-200
    • Georgiadis, D.1    Wenzel, A.2    Zerkowski, H.R.3
  • 9
    • 0031983733 scopus 로고    scopus 로고
    • A new 1-MHz probe for transcranial Doppler sonography in patients with inadequate temporal bone windows
    • Klötsch C, Popescu O, Berlit P. A new 1-MHz probe for transcranial Doppler sonography in patients with inadequate temporal bone windows. Ultrasound Med and Biol 1998:24(1):101-103
    • (1998) Ultrasound Med and Biol , vol.24 , Issue.1 , pp. 101-103
    • Klötsch, C.1    Popescu, O.2    Berlit, P.3
  • 10
    • 0029820286 scopus 로고    scopus 로고
    • Effect of transcranial Doppler intensity on successful recording in Japanese patients
    • Yagita Y, Etani H, Handa N, et al. Effect of transcranial Doppler intensity on successful recording in Japanese patients. Ultrasound Med Biol 1996;22(6):701-705
    • (1996) Ultrasound Med Biol , vol.22 , Issue.6 , pp. 701-705
    • Yagita, Y.1    Etani, H.2    Handa, N.3
  • 11
    • 0025648477 scopus 로고
    • Effect of emitted power on waveform intensity in transcranial Doppler
    • Halsey JH. Effect of emitted power on waveform intensity in transcranial Doppler. Stroke 1990;21(11):1573-1578
    • (1990) Stroke , vol.21 , Issue.11 , pp. 1573-1578
    • Halsey, J.H.1
  • 12
    • 0030069669 scopus 로고    scopus 로고
    • Ultrasound contrast media. New perspectives in ultrasound diagnosis
    • Schlief R, Bauer A. Ultrasound contrast media. New perspectives in ultrasound diagnosis. Radiology 1996;36(1):51-57
    • (1996) Radiology , vol.36 , Issue.1 , pp. 51-57
    • Schlief, R.1    Bauer, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.