메뉴 건너뛰기




Volumn 282, Issue 1-2, 1999, Pages 65-76

A simple and sensitive colorimetric assay of zinc in serum using cationic porphyrin

Author keywords

Colorimetry; Highly sensitive method; Porphyrin reagent; Serum zinc; Trace analysis

Indexed keywords

PORPHYRIN;

EID: 0032959249     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-8981(99)00012-1     Document Type: Article
Times cited : (7)

References (19)
  • 2
    • 0013405973 scopus 로고
    • An improved dithizone method for the determination of small quantities of zinc in blood and tissue samples
    • Vallee B.L., Gibson J.G. An improved dithizone method for the determination of small quantities of zinc in blood and tissue samples. J Biol Chem. 176:1949;435-443.
    • (1949) J Biol Chem , vol.176 , pp. 435-443
    • Vallee, B.L.1    Gibson, J.G.2
  • 3
    • 0014485241 scopus 로고
    • A new spectrophotometric method for determination of zinc in serum and urine
    • Micac-Devic D. A new spectrophotometric method for determination of zinc in serum and urine. Clin Chim Acta. 23:1969;499-506.
    • (1969) Clin Chim Acta , vol.23 , pp. 499-506
    • Micac-Devic, D.1
  • 4
    • 0017286472 scopus 로고
    • A simple, highly sensitive colorimetric method for the determination of zinc in serum
    • Song M.K., Adham N.F., Rinderknecht H. A simple, highly sensitive colorimetric method for the determination of zinc in serum. Am J Clin Pathol. 65:1976;229-233.
    • (1976) Am J Clin Pathol , vol.65 , pp. 229-233
    • Song, M.K.1    Adham, N.F.2    Rinderknecht, H.3
  • 5
    • 0345313847 scopus 로고
    • Study of a differential demasking technique for serum zinc
    • Williams L.A., Cohn J.S., Zak B. Study of a differential demasking technique for serum zinc. Clin Chem. 8:1962;502-508.
    • (1962) Clin Chem , vol.8 , pp. 502-508
    • Williams, L.A.1    Cohn, J.S.2    Zak, B.3
  • 6
    • 0016196797 scopus 로고
    • Spectrophotometric submicrogram serum zinc assay: An application for the routine service laboratory
    • Carter P. Spectrophotometric submicrogram serum zinc assay: an application for the routine service laboratory. Clin Chim Acta. 52:1974;277-355.
    • (1974) Clin Chim Acta , vol.52 , pp. 277-355
    • Carter, P.1
  • 7
    • 0017708283 scopus 로고
    • Essential trace metals. II. Determination of copper and zinc
    • Feldkamp C.S., Watkins R., Baginski E.S., Zak B. Essential trace metals. II. Determination of copper and zinc. Microchem J. 22:1977;347-355.
    • (1977) Microchem J , vol.22 , pp. 347-355
    • Feldkamp, C.S.1    Watkins, R.2    Baginski, E.S.3    Zak, B.4
  • 8
    • 0017736178 scopus 로고
    • Improved colorimetric determination of serum zinc
    • Johnson D.J., Djuh Y.Y., Bruton J., Williams H.L. Improved colorimetric determination of serum zinc. Clin Chem. 23:1977;1321-1323.
    • (1977) Clin Chem , vol.23 , pp. 1321-1323
    • Johnson, D.J.1    Djuh, Y.Y.2    Bruton, J.3    Williams, H.L.4
  • 9
    • 0022247388 scopus 로고
    • Spectrophotometric investigation of sensitive complexing agents for the determination of zinc in serum
    • Homsher R., Zak B. Spectrophotometric investigation of sensitive complexing agents for the determination of zinc in serum. Clin Chem. 31:1985;1310-1313.
    • (1985) Clin Chem , vol.31 , pp. 1310-1313
    • Homsher, R.1    Zak, B.2
  • 10
    • 0018103699 scopus 로고
    • A new micromethod for colorimetric determination of serum zinc using water-soluble pyridylazo dye
    • Ujiie M., Mikami I., Gemba T., Nomura A., Tokudome M., Fujii K. A new micromethod for colorimetric determination of serum zinc using water-soluble pyridylazo dye. Clin Chim Acta. 87:1978;71-76.
    • (1978) Clin Chim Acta , vol.87 , pp. 71-76
    • Ujiie, M.1    Mikami, I.2    Gemba, T.3    Nomura, A.4    Tokudome, M.5    Fujii, K.6
  • 11
    • 0020069965 scopus 로고
    • A highly sensitive colorimetric determination of serum zinc using water-soluble pyridylazo dye
    • Makino T., Saito M., Horiguchi D., Kina K. A highly sensitive colorimetric determination of serum zinc using water-soluble pyridylazo dye. Clin Chim Acta. 120:1982;127-135.
    • (1982) Clin Chim Acta , vol.120 , pp. 127-135
    • Makino, T.1    Saito, M.2    Horiguchi, D.3    Kina, K.4
  • 12
    • 0025981594 scopus 로고
    • A sensitive, direct colorimetric assay of serum zinc using nitro-PAPS and microwell plates
    • Makino T. A sensitive, direct colorimetric assay of serum zinc using nitro-PAPS and microwell plates. Clin Chim Acta. 197:1991;209-220.
    • (1991) Clin Chim Acta , vol.197 , pp. 209-220
    • Makino, T.1
  • 13
    • 0028578638 scopus 로고
    • Automation of colorimetric serum zinc determination with the Bayer RA analyzer
    • Shumcheongsing J., Arnaud J., Favier A. Automation of colorimetric serum zinc determination with the Bayer RA analyzer. Ann Biol Clin. 52:1994;765-768.
    • (1994) Ann Biol Clin , vol.52 , pp. 765-768
    • Shumcheongsing, J.1    Arnaud, J.2    Favier, A.3
  • 14
    • 0019514515 scopus 로고
    • A highly sensitive colorimetric determination of serum copper using α,β,γ,δ-tetrakis(4-N-trimethyl-aminophenyl)porphine
    • Makino T., Itoh J.-I. A highly sensitive colorimetric determination of serum copper using α,β,γ,δ-tetrakis(4-N-trimethyl-aminophenyl)porphine. Clin Chim Acta. 111:1981;1-8.
    • (1981) Clin Chim Acta , vol.111 , pp. 1-8
    • Makino, T.1    Itoh, J.-I.2
  • 15
    • 0000509339 scopus 로고
    • Application of porphyrin in analytical chemistry IV. Spectrophotometric determination of trace amounts of zinc with tetrakis-(4-trimethylammoniumphenyl)porphine
    • Zhang C., Yin F., Cheng J. Application of porphyrin in analytical chemistry IV. Spectrophotometric determination of trace amounts of zinc with tetrakis-(4-trimethylammoniumphenyl)porphine. Fenxi Huaxue. 12:1984;110-114.
    • (1984) Fenxi Huaxue , vol.12 , pp. 110-114
    • Zhang, C.1    Yin, F.2    Cheng, J.3
  • 16
    • 0003259137 scopus 로고
    • Trace elements
    • N.W. Tietz. Philadelphia: W.B.Saunders
    • Jacob R.A. Trace elements. Tietz N.W. Textbook of clinical chemistry. 1986;965-996 W.B.Saunders, Philadelphia.
    • (1986) Textbook of Clinical Chemistry , pp. 965-996
    • Jacob, R.A.1
  • 17
    • 0002326618 scopus 로고
    • New amphoteric ion type water-soluble porphines as a spectrophotometric reagent
    • Igarashi S., Yotsuyanagi T. New amphoteric ion type water-soluble porphines as a spectrophotometric reagent. Chem Lett 1984;1871-1874.
    • (1984) Chem Lett , vol.1871-1874
    • Igarashi, S.1    Yotsuyanagi, T.2
  • 18
    • 0015073862 scopus 로고
    • Some characteristics of trichloroacetic acid-precipitated proteins and their effects on biochemical assays
    • Fielding J., Ryall R.G. Some characteristics of trichloroacetic acid-precipitated proteins and their effects on biochemical assays. Clin Chim Acta. 33:1971;235-240.
    • (1971) Clin Chim Acta , vol.33 , pp. 235-240
    • Fielding, J.1    Ryall, R.G.2
  • 19
    • 0020772996 scopus 로고
    • A potential problem on comparison of plasma with serum for zinc
    • Makino T. A potential problem on comparison of plasma with serum for zinc. Clin Chem. 29:1983;1313-1314.
    • (1983) Clin Chem , vol.29 , pp. 1313-1314
    • Makino, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.