메뉴 건너뛰기




Volumn 24, Issue 3, 1999, Pages 177-181

Intra- and interoperator variations in region-of-interest drawing and their effect on the measurement of glomerular filtration rates

Author keywords

Observer Performance; Quality Control; Regions of Interest; Renal Dynamic Studies

Indexed keywords

ARTICLE; DIAGNOSTIC IMAGING; GLOMERULUS FILTRATION RATE; INTERMETHOD COMPARISON; KIDNEY BLOOD FLOW; KIDNEY FUNCTION; MEASUREMENT; NUCLEAR MEDICINE; OBSERVER VARIATION; QUALITY CONTROL; REPRODUCIBILITY;

EID: 0032959082     PISSN: 03639762     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003072-199903000-00008     Document Type: Article
Times cited : (45)

References (11)
  • 2
    • 0027956486 scopus 로고
    • Reliability of data obtained by radionuclide angiocardiography in follow-up studies with special reference to intra- and interobserver variations
    • Oyamada H, Yamada Y, Nomura E, et al: Reliability of data obtained by radionuclide angiocardiography in follow-up studies with special reference to intra- and interobserver variations. Nucl Med Commun 15:690, 1994
    • (1994) Nucl Med Commun , vol.15 , pp. 690
    • Oyamada, H.1    Yamada, Y.2    Nomura, E.3
  • 3
    • 0344989680 scopus 로고
    • Edge detection: An intercomparison of different algorithms
    • Goris ML, ed. Proceedings of the 7th International Conference, Stanford, California
    • Todd-Popropek A, Kwok CY, Cavailloles F: Edge detection: an intercomparison of different algorithms. In: Goris ML, ed. Information Processing in Medical imaging, Proceedings of the 7th International Conference, Stanford, California, 1981, pp 329-41
    • (1981) Information Processing in Medical Imaging , pp. 329-341
    • Todd-Popropek, A.1    Kwok, C.Y.2    Cavailloles, F.3
  • 4
    • 0025061841 scopus 로고
    • Cluster analysis for automatic image segmentation in dynamic scintigraphies
    • Hannequin P, Liehn JC, Valeyre J: Cluster analysis for automatic image segmentation in dynamic scintigraphies. Nucl Med Commun 11:383, 1990
    • (1990) Nucl Med Commun , vol.11 , pp. 383
    • Hannequin, P.1    Liehn, J.C.2    Valeyre, J.3
  • 5
    • 0344989678 scopus 로고
    • Automatic regions of interest using image registration
    • Houston AS, Kemp PM, Macleod MA: Automatic regions of interest using image registration [Abstract]. Nucl Med Commun 15:207, 1994
    • (1994) Nucl Med Commun , vol.15 , pp. 207
    • Houston, A.S.1    Kemp, P.M.2    Macleod, M.A.3
  • 6
    • 0345420789 scopus 로고    scopus 로고
    • The use of artificial neural networks for the automatic definition of regions of interest
    • Houston AS, White DRR, Sampson WFD, Pilkington JB: The use of artificial neural networks for the automatic definition of regions of interest [Abstract]. Nucl Med Commun 18:312, 1997
    • (1997) Nucl Med Commun , vol.18 , pp. 312
    • Houston, A.S.1    White, D.R.R.2    Sampson, W.F.D.3    Pilkington, J.B.4
  • 7
    • 0345420790 scopus 로고    scopus 로고
    • A new user friendly renal dynamic phantom for assessing GFR measurement from radionuclide images
    • Sampson WFD, Houston AS, Moslin R: A new user friendly renal dynamic phantom for assessing GFR measurement from radionuclide images [Abstract]. Eur J Nucl Med 24:922, 1997
    • (1997) Eur J Nucl Med , vol.24 , pp. 922
    • Sampson, W.F.D.1    Houston, A.S.2    Moslin, R.3
  • 8
    • 0344127080 scopus 로고
    • Estimation of total and single kidney GFR from renography
    • Sampson WFD, Jenkins L: Estimation of total and single kidney GFR from renography. Nucl Med Commun 5:275, 1984
    • (1984) Nucl Med Commun , vol.5 , pp. 275
    • Sampson, W.F.D.1    Jenkins, L.2
  • 9
    • 0031016255 scopus 로고    scopus 로고
    • A quantitative comparison of some FADS methods in renal dynamic studies using simulated and phantom data
    • Houston AS, Sampson WFD: A quantitative comparison of some FADS methods in renal dynamic studies using simulated and phantom data. Phys Med Biol 42:199, 1997
    • (1997) Phys Med Biol , vol.42 , pp. 199
    • Houston, A.S.1    Sampson, W.F.D.2
  • 11
    • 0018736466 scopus 로고
    • A compartmental model for the distribution of In-113 DTPA and Tc-99m (Sn)DTPA in man following intravenous injection
    • Houston AS, Sampson WFD, Macleod MA: A compartmental model for the distribution of In-113 DTPA and Tc-99m (Sn)DTPA in man following intravenous injection. Int J Nucl Med Biol 6:85, 1979
    • (1979) Int J Nucl Med Biol , vol.6 , pp. 85
    • Houston, A.S.1    Sampson, W.F.D.2    Macleod, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.