메뉴 건너뛰기




Volumn 18, Issue 3, 1999, Pages 47-55

Neuro-electronic interfacing with multielectrode arrays: Selectivity and efficiency of motor-fiber stimulation, toward a cultured probe

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRONIC MEDICAL EQUIPMENT; FUNCTIONAL ELECTRIC STIMULATION; MICROELECTRODES; MUSCLE;

EID: 0032957096     PISSN: 07395175     EISSN: None     Source Type: Journal    
DOI: 10.1109/51.765188     Document Type: Review
Times cited : (35)

References (29)
  • 1
    • 0030315469 scopus 로고    scopus 로고
    • Fabrication of multi electrode array structures for intra-neural stimulation: Assess-ment of the LIGA method
    • Amsterdam (CD-ROM), 2 pp.
    • Bielen JA, Schmidt AW, Weiel R, and Rutten WLC: Fabrication of multi electrode array structures for intra-neural stimulation: assess-ment of the LIGA method. Proc 18th Int Conf Eng in Med & Biol., Amsterdam (CD-ROM), 2 pp. 1996.
    • (1996) Proc 18th Int Conf Eng in Med & Biol.
    • Bielen, J.A.1    Schmidt, A.W.2    Weiel, R.3    Rutten, W.L.C.4
  • 4
    • 84944495224 scopus 로고
    • Properties of motor units in fast and slow skeletal muscles of the rat
    • Close, R:. Properties of motor units in fast and slow skeletal muscles of the rat. J Physiology 193: 45-55, 1967.
    • (1967) J Physiology , vol.193 , pp. 45-55
    • Close, R.1
  • 5
    • 0022559394 scopus 로고
    • A peripheral nerve information transducer for amputees: Long-term multichannel recordings from rabbit peripheral nerves
    • Edell, DJ: A peripheral nerve information transducer for amputees: long-term multichannel recordings from rabbit peripheral nerves. IEEE Trans Biomed Eng 33: 203-214, 1986.
    • (1986) IEEE Trans Biomed Eng , vol.33 , pp. 203-214
    • Edell, D.J.1
  • 6
    • 0026882265 scopus 로고
    • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
    • Edell DJ, Toi VV, McNeil VM and Clark LD: Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE Trans Biomed Eng 39:635-643, 1992.
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 635-643
    • Edell, D.J.1    Toi, V.V.2    McNeil, V.M.3    Clark, L.D.4
  • 8
    • 0344256295 scopus 로고
    • Nevis: Neural visualization of factors influencing force recruitment in intraneural stimulation, part I and part II
    • Frieswijk TA and Rutten WLC: NEVIS: NEural Visualization of factors influencing force recruitment in intraneural stimulation, Part I and Part II, Proc 16th Int Conf IEEE Eng Med Biol Soc, pp. 359-362, 1994.
    • (1994) Proc 16th Int Conf IEEE Eng Med Biol Soc , pp. 359-362
    • Frieswijk, T.A.1    Rutten, W.L.C.2
  • 9
    • 0028758397 scopus 로고
    • Three-dimensional neuro-electronic interface for peripheral nerve stimulation and recording: Realisation steps and contacting technology
    • Frieswijk TA and Rutten WLC: Three-dimensional neuro-electronic interface for peripheral nerve stimulation and recording: realisation steps and contacting technology. Proc 16th Int Conf IEEE Eng Med Biol Soc, pp. 361-362 1994.
    • (1994) Proc 16th Int Conf IEEE Eng Med Biol Soc , pp. 361-362
    • Frieswijk, T.A.1    Rutten, W.L.C.2
  • 11
    • 0029431413 scopus 로고
    • Development of a solder bump technique for contacting a three-dimensional multi electrode array
    • Montreal, 2 pp.
    • Frieswijk TA, Bielen JA and Rutten WLC: Development of a solder bump technique for contacting a three-dimensional multi electrode array, Proc 17th Int Conf Eng in Med & Biol, Montreal, 2 pp., 1995.
    • (1995) Proc 17th Int Conf Eng in Med & Biol
    • Frieswijk, T.A.1    Bielen, J.A.2    Rutten, W.L.C.3
  • 12
    • 0028034642 scopus 로고
    • Cell manipulation and cultivation under ac electric field influence in highly conductive culture media
    • Fuhr G, Glasser H, Müller T, Schnelle Th: Cell manipulation and cultivation under AC electric field influence in highly conductive culture media. Biochem Biophys Acta 1201: 353-360, 1994.
    • (1994) Biochem Biophys Acta , vol.1201 , pp. 353-360
    • Fuhr, G.1    Glasser, H.2    Müller, T.3    Schnelle, Th.4
  • 14
    • 0028662508 scopus 로고
    • A 3D micro-electrode array for chronic neural recording
    • Hoogerwerf AC and Wise KD: A 3D micro-electrode array for chronic neural recording. IEEE Trans Biomed Eng 41: 1136-1146, 1994.
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 1136-1146
    • Hoogerwerf, A.C.1    Wise, K.D.2
  • 16
    • 0030312124 scopus 로고    scopus 로고
    • Perforated silicon membranes as an artificial neural contact pad-chip design and tissue implant response
    • Amsterdam, ISBN 90-901005-9 (CD-ROM), 2 pp.
    • Laurell T, Drott J, Zhao Q, Wallman L, Montelius L, et al.: Perforated silicon membranes as an artificial neural contact pad-chip design and tissue implant response. Proc 18th Int Conf Eng in Med & Biol Soc, Amsterdam, ISBN 90-901005-9 (CD-ROM), 2 pp., 1996.
    • (1996) Proc 18th Int Conf Eng in Med & Biol Soc
    • Laurell, T.1    Drott, J.2    Zhao, Q.3    Wallman, L.4    Montelius, L.5
  • 17
    • 0028898835 scopus 로고
    • The linear and non-linear electrical properties of the electrode-electrolyte interface
    • McAdams ET, Lackermeier A, McLaughlin JA, Macken D: The linear and non-linear electrical properties of the electrode-electrolyte interface. Biosens & Biolelectr, 10, pp. 67-74, 1995.
    • (1995) Biosens & Biolelectr , vol.10 , pp. 67-74
    • McAdams, E.T.1    Lackermeier, A.2    McLaughlin, J.A.3    Macken, D.4
  • 19
    • 0029294490 scopus 로고
    • Force recruitment during electrical nerve stimulation with multipolar intrafascicular electrodes
    • 3
    • Meier JH, Rutten WLC, and Boom HBK: Force recruitment during electrical nerve stimulation with multipolar intrafascicular electrodes. Medical & Biological Engineering & Computing, 33-3: 409-417, 1995.
    • (1995) Medical & Biological Engineering & Computing , vol.33 , pp. 409-417
    • Meier, J.H.1    Rutten, W.L.C.2    Boom, H.B.K.3
  • 20
    • 0028144251 scopus 로고
    • Optimizing recording capabilities of the Utah intracortical electrode array
    • Nordhausen CT, Rousche PJ, and Normann RA: Optimizing recording capabilities of the Utah intracortical electrode array. Brain Research 637: 27-36, 1994.
    • (1994) Brain Research , vol.637 , pp. 27-36
    • Nordhausen, C.T.1    Rousche, P.J.2    Normann, R.A.3
  • 21
    • 0022495190 scopus 로고
    • Motor, sympathetic, and sensory innervation of rat skeletal muscle
    • Peyronnard JM, Charron LF, Lavoie J, and Messier JP: Motor, sympathetic, and sensory innervation of rat skeletal muscle. Brain Research 373: 288-302, 1986.
    • (1986) Brain Research , vol.373 , pp. 288-302
    • Peyronnard, J.M.1    Charron, L.F.2    Lavoie, J.3    Messier, J.P.4
  • 22
    • 0026106143 scopus 로고
    • Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
    • Rutten WLC, van Wier H & Put JMH: Sensitivity and selectivity of intraneural stimulation using a silicon electrode array. IEEE Trans Biomed Eng, 38:192-198, 1991.
    • (1991) IEEE Trans Biomed Eng , vol.38 , pp. 192-198
    • Rutten, W.L.C.1    Van Wier, H.2    Put, J.M.H.3
  • 25
    • 0029429338 scopus 로고
    • Intraneural stimulation using 2-D wire-microelectrode arrays I. Experimental results
    • Montreal (CD-ROM), 4 pp.
    • Smit JPA and Rutten WLC: Intraneural stimulation using 2-D wire-microelectrode arrays I. Experimental results, Proc 17th Int Conf Eng in Med & Biol. Montreal (CD-ROM), 4 pp., 1995.
    • (1995) Proc 17th Int Conf Eng in Med & Biol.
    • Smit, J.P.A.1    Rutten, W.L.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.