메뉴 건너뛰기




Volumn 82, Issue 2, 1999, Pages 291-294

Liability of laryngeal mask airway devices to thermal damage from KTP and Nd:YAG lasers

Author keywords

Equipment, lasers; Equipment, masks anaesthesia; Surgery, otolaryngological

Indexed keywords

METHYLENE BLUE; POLYVINYLCHLORIDE; SILASTIC; SILICONE; STEEL;

EID: 0032953557     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/bja/82.2.291     Document Type: Article
Times cited : (14)

References (15)
  • 2
  • 5
    • 0029036640 scopus 로고
    • Anaesthesia for laser pharyngoplasty - A comparison of the tracheal tube verses reinforced laryngeal mask airway
    • Sher M, Brimacombe J, Laing D. Anaesthesia for laser pharyngoplasty - a comparison of the tracheal tube verses reinforced laryngeal mask airway. Anaesth Intensive Care 1995; 23: 149-54
    • (1995) Anaesth Intensive Care , vol.23 , pp. 149-154
    • Sher, M.1    Brimacombe, J.2    Laing, D.3
  • 6
    • 0028566188 scopus 로고
    • 2 laser strike - A comparison with two polyvinyl chloride tracheal tubes
    • 2 laser strike - a comparison with two polyvinyl chloride tracheal tubes. Anaesth Intensive Care 1994; 22: 694-7
    • (1994) Anaesth Intensive Care , vol.22 , pp. 694-697
    • Brimacombe, J.1
  • 7
    • 0031008882 scopus 로고    scopus 로고
    • KTP laser-resistant properties of the reinforced laryngeal mask airway
    • Pandit JJ, Chambers P, O'Malley SO. KTP laser-resistant properties of the reinforced laryngeal mask airway. Br J Anaesth 1997; 78: 594-600
    • (1997) Br J Anaesth , vol.78 , pp. 594-600
    • Pandit, J.J.1    Chambers, P.2    O'Malley, S.O.3
  • 8
    • 0030840388 scopus 로고    scopus 로고
    • The intubating laryngeal mask. I: Development of a new device for intubation of the trachea
    • Brain AIJ, Verghese C, Addy EV, Kapila A. The intubating laryngeal mask. I: development of a new device for intubation of the trachea. Br J Anaesth 1997; 79: 699-703
    • (1997) Br J Anaesth , vol.79 , pp. 699-703
    • Brain, A.I.J.1    Verghese, C.2    Addy, E.V.3    Kapila, A.4
  • 9
    • 0030815777 scopus 로고    scopus 로고
    • The intubating laryngeal mask. Il: A preliminary clinical report of a new means of intubating the trachea
    • Brain AIJ, Verghese C, Addy EV, Kapila A, Brimacombe J. The intubating laryngeal mask. Il: a preliminary clinical report of a new means of intubating the trachea. Br J Anaesth 1997; 79: 704-9
    • (1997) Br J Anaesth , vol.79 , pp. 704-709
    • Brain, A.I.J.1    Verghese, C.2    Addy, E.V.3    Kapila, A.4    Brimacombe, J.5
  • 10
    • 0031966845 scopus 로고    scopus 로고
    • A clinical assessment of the single use laryngeal mask airway the LMA-UNIQUE
    • Verghese C, Berlet J, Kapila A, Pollard R. A clinical assessment of the single use laryngeal mask airway the LMA-UNIQUE. Br J Anaesth 1998; 80:677-9
    • (1998) Br J Anaesth , vol.80 , pp. 677-679
    • Verghese, C.1    Berlet, J.2    Kapila, A.3    Pollard, R.4
  • 11
    • 0022521118 scopus 로고
    • Incendiary characteristics of a new laser-resistant endotracheal tube
    • Hayes DM, Gaba DM, Goode RL. Incendiary characteristics of a new laser-resistant endotracheal tube. Otoloryngol Head Neck Surg 1986; 95: 37-40
    • (1986) Otoloryngol Head Neck Surg , vol.95 , pp. 37-40
    • Hayes, D.M.1    Gaba, D.M.2    Goode, R.L.3
  • 12
    • 0028245892 scopus 로고
    • The effect of blood on laser-resistant endotracheal tube combustion
    • Sosis MB, Pritikin JB, Caldarelli DD. The effect of blood on laser-resistant endotracheal tube combustion. Laryngoscope 1994; 104: 829-31
    • (1994) Laryngoscope , vol.104 , pp. 829-831
    • Sosis, M.B.1    Pritikin, J.B.2    Caldarelli, D.D.3
  • 13
    • 0013074905 scopus 로고
    • Basic laser physics and interaction of laser light with soft tissue
    • Shapsay SM, ed. New York: Marcel Dekker
    • Fisher JC. Basic laser physics and interaction of laser light with soft tissue. In: Shapsay SM, ed. Endoscopic Laser Surgery Handbook. New York: Marcel Dekker, 1987
    • (1987) Endoscopic Laser Surgery Handbook
    • Fisher, J.C.1
  • 14
    • 0030668142 scopus 로고    scopus 로고
    • Damage to the laryngeal mask by residual fluid in the cuff
    • Asai T, Koga K, Morris S. Damage to the laryngeal mask by residual fluid in the cuff. Anaesthesia 1997; 52: 977-81
    • (1997) Anaesthesia , vol.52 , pp. 977-981
    • Asai, T.1    Koga, K.2    Morris, S.3
  • 15
    • 0031671185 scopus 로고    scopus 로고
    • Saline as an alternative to air for filling the laryngeal mask airway cuff
    • Coorey A, Brimacombe J, Keller C. Saline as an alternative to air for filling the laryngeal mask airway cuff. Br J Anaesth 1998; 81: 398-400
    • (1998) Br J Anaesth , vol.81 , pp. 398-400
    • Coorey, A.1    Brimacombe, J.2    Keller, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.