메뉴 건너뛰기




Volumn 115, Issue 5, 1999, Pages 1316-1320

Determination of hemoglobin saturation in patients with acute sickle chest syndrome: A comparison of arterial blood gases and pulse oximetry

Author keywords

Arterial blood gas; Co oximetry; Exchange transfusion; Oxygen dissociation curve; Pulse oximetry; Sickle cell anemia

Indexed keywords

ADULT; ALGORITHM; ARTERIAL GAS; ARTERIAL OXYGEN TENSION; ARTICLE; CLINICAL ARTICLE; ELECTROPHORESIS; EXCHANGE BLOOD TRANSFUSION; FEMALE; HUMAN; MALE; OXYGEN DISSOCIATION CURVE; OXYGEN SATURATION; PRIORITY JOURNAL; PULSE OXIMETRY; SICKLE CELL ANEMIA;

EID: 0032951982     PISSN: 00123692     EISSN: None     Source Type: Journal    
DOI: 10.1378/chest.115.5.1316     Document Type: Article
Times cited : (42)

References (22)
  • 1
    • 0028291736 scopus 로고
    • Mortality in sickle cell disease: Life expectancy and risk factors for early death
    • 1 Platt OS, Brambilla DJ, Rosse WF, et al. Mortality in sickle cell disease: life expectancy and risk factors for early death. N Engl J Med 1994; 330:1639-1644
    • (1994) N Engl J Med , vol.330 , pp. 1639-1644
    • Platt, O.S.1    Brambilla, D.J.2    Rosse, W.F.3
  • 2
    • 0028244891 scopus 로고
    • Pulmonary fat embolism: A distinct cause of severe acute chest syndrome in sickle cell anemia
    • 2 Vichinsky E, Williams R, Das M, et al. Pulmonary fat embolism: a distinct cause of severe acute chest syndrome in sickle cell anemia. Blood 1994; 83:3107-3112
    • (1994) Blood , vol.83 , pp. 3107-3112
    • Vichinsky, E.1    Williams, R.2    Das, M.3
  • 3
    • 0014189134 scopus 로고
    • Infarction of bone marrow in the sickle cell disorders
    • 3 Charache S, Page DL. Infarction of bone marrow in the sickle cell disorders. Ann Intern Med 1967; 67:1195-1200
    • (1967) Ann Intern Med , vol.67 , pp. 1195-1200
    • Charache, S.1    Page, D.L.2
  • 4
    • 0018630984 scopus 로고
    • The diagnosis of pulmonary thromboembolism in sickle cell disease
    • 4 Walker BK, Ballas SK, Burka ER. The diagnosis of pulmonary thromboembolism in sickle cell disease. Am J Hematol 1979; 7:219-232
    • (1979) Am J Hematol , vol.7 , pp. 219-232
    • Walker, B.K.1    Ballas, S.K.2    Burka, E.R.3
  • 5
    • 0027450929 scopus 로고
    • Acute chest syndrome in sickle cell disease: CT evidence of microvascular occlusion
    • 5 Bhalla M, Abboud MR, McLoud TC, et al. Acute chest syndrome in sickle cell disease: CT evidence of microvascular occlusion. Radiology 1993; 187:45-49
    • (1993) Radiology , vol.187 , pp. 45-49
    • Bhalla, M.1    Abboud, M.R.2    McLoud, T.C.3
  • 6
    • 0025735533 scopus 로고
    • Rib infarcts and acute chest syndrome in sickle cell diseases
    • 6 Rucknagel DL, Kalinyak KA, Gelfand MJ. Rib infarcts and acute chest syndrome in sickle cell diseases. Lancet 1991; 337:831-833
    • (1991) Lancet , vol.337 , pp. 831-833
    • Rucknagel, D.L.1    Kalinyak, K.A.2    Gelfand, M.J.3
  • 7
    • 0030022822 scopus 로고    scopus 로고
    • Pulmonary entrapment of sickle cells: The role of regional alveolar hypoxia
    • 7 Aldrich TK, Dhuper SK, Patwa NS, et al. Pulmonary entrapment of sickle cells: the role of regional alveolar hypoxia. J Appl Physiol 1996; 80:531-539
    • (1996) J Appl Physiol , vol.80 , pp. 531-539
    • Aldrich, T.K.1    Dhuper, S.K.2    Patwa, N.S.3
  • 9
    • 0019753772 scopus 로고
    • Oxygen binding to sickle cell hemoglobin
    • 9 DeYoung A, Noble RW. Oxygen binding to sickle cell hemoglobin. Methods Enzymol 1981; 76:792-805
    • (1981) Methods Enzymol , vol.76 , pp. 792-805
    • DeYoung, A.1    Noble, R.W.2
  • 10
    • 0020318201 scopus 로고
    • Oxygen binding by sickle cell hemoglobin polymers
    • 10 Sunshine HR, Hofrichter J, Ferrone FA, et al. Oxygen binding by sickle cell hemoglobin polymers. J Mol Biol 1982; 158:251-273
    • (1982) J Mol Biol , vol.158 , pp. 251-273
    • Sunshine, H.R.1    Hofrichter, J.2    Ferrone, F.A.3
  • 11
    • 0023968368 scopus 로고
    • Bias and precision of pulse oximeters and arterial oximeters
    • 11 Nickerson BG, Sarkisian G, Tremper K. Bias and precision of pulse oximeters and arterial oximeters. Chest 1988; 93:515-517
    • (1988) Chest , vol.93 , pp. 515-517
    • Nickerson, B.G.1    Sarkisian, C.2    Tremper, K.3
  • 13
    • 0028058019 scopus 로고
    • Comparison of oxygenation measurements in pediatric patients during sickle cell crises
    • 13 Craft JA, Alessandrini E, Kenney LB, et al. Comparison of oxygenation measurements in pediatric patients during sickle cell crises. J Pediatr 1994; 124:93-95
    • (1994) J Pediatr , vol.124 , pp. 93-95
    • Craft, J.A.1    Alessandrini, E.2    Kenney, L.B.3
  • 14
    • 0027272159 scopus 로고
    • Pulse oximetry and factors associated with hemoglobin oxygen desaturation in children with sickle cell disease
    • 14 Rackoff WR, Kunkel N, Silber JH, et al. Pulse oximetry and factors associated with hemoglobin oxygen desaturation in children with sickle cell disease. Blood 1993; 81:3422-3427
    • (1993) Blood , vol.81 , pp. 3422-3427
    • Rackoff, W.R.1    Kunkel, N.2    Silber, J.H.3
  • 15
    • 0030021773 scopus 로고    scopus 로고
    • Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisis
    • 15 Comber JT, Lopez BL. Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisis. Am J Emerg Med 1996; 14: 16-18
    • (1996) Am J Emerg Med , vol.14 , pp. 16-18
    • Comber, J.T.1    Lopez, B.L.2
  • 16
    • 0028226841 scopus 로고
    • Pulse oximetry in sickle cell disease
    • 16 Jones SW. Pulse oximetry in sickle cell disease [letter]. Arch Dis Child 1994; 70:71
    • (1994) Arch Dis Child , vol.70 , pp. 71
    • Jones, S.W.1
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 17 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 0023406009 scopus 로고
    • Pulse oximetry: Applications and limitations
    • 20 Barker SJ, Tremper KK. Pulse oximetry: applications and limitations. Int Anesthesiol Clin 1987; 25:155-175
    • (1987) Int Anesthesiol Clin , vol.25 , pp. 155-175
    • Barker, S.J.1    Tremper, K.K.2
  • 21
    • 0025170596 scopus 로고
    • Pulse oximeter failure thresholds in hypotension and vasoconstriction
    • 21 Severinghaus JW, Spellman MJ. Pulse oximeter failure thresholds in hypotension and vasoconstriction. Anesthesiology 1990; 73:532-537
    • (1990) Anesthesiology , vol.73 , pp. 532-537
    • Severinghaus, J.W.1    Spellman, M.J.2
  • 22
    • 0026535794 scopus 로고
    • The influence of changes in blood flow on the accuracy of pulse oximetry in humans
    • 22 Vegfors M, Lindberg LG, Lennmarken C. The influence of changes in blood flow on the accuracy of pulse oximetry in humans. Acta Anaesthesiol Scand 1992; 36:346-349
    • (1992) Acta Anaesthesiol Scand , vol.36 , pp. 346-349
    • Vegfors, M.1    Lindberg, L.G.2    Lennmarken, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.