Volumn 46, Issue 2, 1999, Pages 194-196

A comparison of arterial versus venous-activated clotting time in patients with congenital heart disease undergoing cardiac catheterization

Author keywords

Activated clotting time; Cardiac catheterization; Congenital heart disease

Indexed keywords

HEPARIN;

EID: 0032951974     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/(SICI)1522-726X(199902)46:2<194::AID-CCD16>3.0.CO;2-M     Document Type: Article
Times cited : (5)

References (10)
  • 1
    • 0016269486 scopus 로고
    • The use of heparinization to prevent arterial thrombosis after percutaneous cardiac catheterization in children
    • Freed MD, Keane JF, Rosenthal A. The use of heparinization to prevent arterial thrombosis after percutaneous cardiac catheterization in children. Circulation 1974;50:565-569.
    • (1974) Circulation , vol.50 , pp. 565-569
    • Freed, M.D.1    Keane, J.F.2    Rosenthal, A.3
  • 2
    • 0020362895 scopus 로고
    • Heparinization for prevention of thrombosis following pediatric percutaneous arterial catheterization
    • Girod DA, Hurwitz RA, Caldwell RL. Heparinization for prevention of thrombosis following pediatric percutaneous arterial catheterization. Pediatr Cardiol 1982;3:175-180.
    • (1982) Pediatr Cardiol , vol.3 , pp. 175-180
    • Girod, D.A.1    Hurwitz, R.A.2    Caldwell, R.L.3
  • 3
    • 0028918043 scopus 로고
    • Rational approach to use heparin during cardiac catheterization in children
    • Grady RM, Eisenberg PR, Bridges ND. Rational approach to use heparin during cardiac catheterization in children. J Am Coll Cardiol 1995;25:725-729.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 725-729
    • Grady, R.M.1    Eisenberg, P.R.2    Bridges, N.D.3
  • 4
    • 0025073299 scopus 로고
    • Monitoring the effect of heparin by measurement of activated clotting time during and after percutaneous transluminal coronary angiography
    • Rath B, Bennett DH. Monitoring the effect of heparin by measurement of activated clotting time during and after percutaneous transluminal coronary angiography. Br Heart J 1990;63:18-21.
    • (1990) Br Heart J , vol.63 , pp. 18-21
    • Rath, B.1    Bennett, D.H.2
  • 5
    • 0028363680 scopus 로고
    • Activated clotting-time variability in patients undergoing coronary angioplasty
    • Warner MF, Mian MS, Missri JC. Activated clotting-time variability in patients undergoing coronary angioplasty. Clin Cardiol 1994;17:372-374.
    • (1994) Clin Cardiol , vol.17 , pp. 372-374
    • Warner, M.F.1    Mian, M.S.2    Missri, J.C.3
  • 6
    • 0030048441 scopus 로고    scopus 로고
    • Percutaneous transluminal coronary angioplasty: Comparison of arterial vs. venous activated clotting time
    • Pesola GR, Johnson A, Pesola DA. Percutaneous transluminal coronary angioplasty: comparison of arterial vs. venous activated clotting time. Cath Cardiovasc Diagn 1996;37:140-144.
    • (1996) Cath Cardiovasc Diagn , vol.37 , pp. 140-144
    • Pesola, G.R.1    Johnson, A.2    Pesola, D.A.3
  • 7
    • 0030344746 scopus 로고    scopus 로고
    • Intermediate-term outcome of transcatheter secundum atrial septal defect closure using the Bard clamshell septal umbrella
    • Prieto LR, Foreman CK, Cheatham JP, Latson LA. Intermediate-term outcome of transcatheter secundum atrial septal defect closure using the Bard clamshell septal umbrella. Am J Cardiol 1996;77:1310-1312.
    • (1996) Am J Cardiol , vol.77 , pp. 1310-1312
    • Prieto, L.R.1    Foreman, C.K.2    Cheatham, J.P.3    Latson, L.A.4
  • 8
    • 0030049157 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion System (ASDOS): Initial experience in children
    • Hausdorf G, Schneider M, Franzbach B. Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion System (ASDOS): initial experience in children. Heart 1996;75:83-88.
    • (1996) Heart , vol.75 , pp. 83-88
    • Hausdorf, G.1    Schneider, M.2    Franzbach, B.3
  • 9
    • 0028261576 scopus 로고
    • Comparison of Hemochron and Hemo Tec activated coagulation time target values during percutaneous transluminal coronary angioplasty
    • Avendano A, Ferguson JJ. Comparison of Hemochron and Hemo Tec activated coagulation time target values during percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 1994;23:907-910.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 907-910
    • Avendano, A.1    Ferguson, J.J.2
  • 10
    • 0030074644 scopus 로고    scopus 로고
    • When we "act" on ACT levels: Activated clotting time measurements to guide heparin administration during and after interventional procedures
    • Klein LW, Agarwal JB. When we "act" on ACT levels: activated clotting time measurements to guide heparin administration during and after interventional procedures. Cath Cardiovasc Diagn 1996; 37:154-157.
    • (1996) Cath Cardiovasc Diagn , vol.37 , pp. 154-157
    • Klein, L.W.1    Agarwal, J.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.