1
-
-
0002629797
-
Tissue equivalent torso phantom for intercalibration of in vivo transuranic nuclide counting facilities. In: Advances in radiation monitoring
-
Vienna: IAEA; IAEA-SM-229/56
-
Griffith, R. V.; Dean, P. N.; Anderson, A. L.; Fisher, J. C. Tissue equivalent torso phantom for intercalibration of in vivo transuranic nuclide counting facilities. In: Advances in radiation monitoring, Proceedings of an International Atomic Energy Agency conference. Vienna: IAEA; IAEA-SM-229/56, 4493-504; 1978.
-
(1978)
Proceedings of An International Atomic Energy Agency Conference
, pp. 4493-4504
-
-
Griffith, R.V.1
Dean, P.N.2
Anderson, A.L.3
Fisher, J.C.4
-
3
-
-
0026317607
-
A summary of the proceedings of the workshop on standard Phantoms for in Vivo Radioactivity Measurement
-
Kramer, G. H.; Inn, K. G. W. A summary of the proceedings of the Workshop on Standard Phantoms for In Vivo Radioactivity Measurement. Health Phys. 61:893-894; 1991.
-
(1991)
Health Phys.
, vol.61
, pp. 893-894
-
-
Kramer, G.H.1
Inn, K.G.W.2
-
4
-
-
0028284358
-
The Canadian National Calibration Reference Centre for Bioassay and in Vivo Monitoring: A program summary
-
Kramer, G. H.; Limson Zamora, M. The Canadian National Calibration Reference Centre for Bioassay and In Vivo Monitoring: a program summary. Health Phys. 67:192-196; 1994.
-
(1994)
Health Phys.
, vol.67
, pp. 192-196
-
-
Kramer, G.H.1
Limson Zamora, M.2
-
5
-
-
0030746961
-
Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium counting
-
Kramer, G. H.; Hauck, B. M. Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium counting. Health Phys. 73:831-837; 1997.
-
(1997)
Health Phys.
, vol.73
, pp. 831-837
-
-
Kramer, G.H.1
Hauck, B.M.2
-
6
-
-
0031921069
-
A joint HML-KAERI project: Comparison of the LLNL and JAERI torso phantoms using four 50 mm Ge detectors
-
Kramer, G. H.; Lee, T-Y.; Soo, K-J. A joint HML-KAERI project: Comparison of the LLNL and JAERI torso phantoms using four 50 mm Ge detectors. Health Phys. 74:613-618; 1998.
-
(1998)
Health Phys.
, vol.74
, pp. 613-618
-
-
Kramer, G.H.1
Lee, T.Y.2
Soo, K.J.3
-
7
-
-
0031438877
-
Lung counting: Evaluation of uncertainties in lung burden estimation arising from a heterogeneous deposition using Monte Carlo code simulations
-
Kramer, G. H.; Burns, L. C.; Yiu, S. Lung counting: evaluation of uncertainties in lung burden estimation arising from a heterogeneous deposition using Monte Carlo code simulations. Radiat. Protect. Dosim. 74:173-182; 1997.
-
(1997)
Radiat. Protect. Dosim.
, vol.74
, pp. 173-182
-
-
Kramer, G.H.1
Burns, L.C.2
Yiu, S.3
-
8
-
-
0024105319
-
Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities
-
Shirotani, T. Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities. J. Nucl Sci. Tech. 25:875-883; 1988.
-
(1988)
J. Nucl Sci. Tech.
, vol.25
, pp. 875-883
-
-
Shirotani, T.1
-
9
-
-
0018361004
-
Reference Japanese Man I - Mass of organs and other characteristics of normal Japanese
-
Tanaka, G.; Kawamura, H.; Nakahara, Y. Reference Japanese Man I - mass of organs and other characteristics of normal Japanese. Health Phys. 36:333-346; 1979.
-
(1979)
Health Phys.
, vol.36
, pp. 333-346
-
-
Tanaka, G.1
Kawamura, H.2
Nakahara, Y.3
|