메뉴 건너뛰기




Volumn 76, Issue 5, 1999, Pages 547-552

Comparison of sliced and whole lung sets for the LLNL and JAERI torso phantoms using GE detectors

Author keywords

Calibration; Detector, germanium; Lungs, human; Phantom

Indexed keywords

AMERICIUM 241; EUROPIUM;

EID: 0032951809     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-199905000-00013     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 0002629797 scopus 로고
    • Tissue equivalent torso phantom for intercalibration of in vivo transuranic nuclide counting facilities. In: Advances in radiation monitoring
    • Vienna: IAEA; IAEA-SM-229/56
    • Griffith, R. V.; Dean, P. N.; Anderson, A. L.; Fisher, J. C. Tissue equivalent torso phantom for intercalibration of in vivo transuranic nuclide counting facilities. In: Advances in radiation monitoring, Proceedings of an International Atomic Energy Agency conference. Vienna: IAEA; IAEA-SM-229/56, 4493-504; 1978.
    • (1978) Proceedings of An International Atomic Energy Agency Conference , pp. 4493-4504
    • Griffith, R.V.1    Dean, P.N.2    Anderson, A.L.3    Fisher, J.C.4
  • 3
    • 0026317607 scopus 로고
    • A summary of the proceedings of the workshop on standard Phantoms for in Vivo Radioactivity Measurement
    • Kramer, G. H.; Inn, K. G. W. A summary of the proceedings of the Workshop on Standard Phantoms for In Vivo Radioactivity Measurement. Health Phys. 61:893-894; 1991.
    • (1991) Health Phys. , vol.61 , pp. 893-894
    • Kramer, G.H.1    Inn, K.G.W.2
  • 4
    • 0028284358 scopus 로고
    • The Canadian National Calibration Reference Centre for Bioassay and in Vivo Monitoring: A program summary
    • Kramer, G. H.; Limson Zamora, M. The Canadian National Calibration Reference Centre for Bioassay and In Vivo Monitoring: a program summary. Health Phys. 67:192-196; 1994.
    • (1994) Health Phys. , vol.67 , pp. 192-196
    • Kramer, G.H.1    Limson Zamora, M.2
  • 5
    • 0030746961 scopus 로고    scopus 로고
    • Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium counting
    • Kramer, G. H.; Hauck, B. M. Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium counting. Health Phys. 73:831-837; 1997.
    • (1997) Health Phys. , vol.73 , pp. 831-837
    • Kramer, G.H.1    Hauck, B.M.2
  • 6
    • 0031921069 scopus 로고    scopus 로고
    • A joint HML-KAERI project: Comparison of the LLNL and JAERI torso phantoms using four 50 mm Ge detectors
    • Kramer, G. H.; Lee, T-Y.; Soo, K-J. A joint HML-KAERI project: Comparison of the LLNL and JAERI torso phantoms using four 50 mm Ge detectors. Health Phys. 74:613-618; 1998.
    • (1998) Health Phys. , vol.74 , pp. 613-618
    • Kramer, G.H.1    Lee, T.Y.2    Soo, K.J.3
  • 7
    • 0031438877 scopus 로고    scopus 로고
    • Lung counting: Evaluation of uncertainties in lung burden estimation arising from a heterogeneous deposition using Monte Carlo code simulations
    • Kramer, G. H.; Burns, L. C.; Yiu, S. Lung counting: evaluation of uncertainties in lung burden estimation arising from a heterogeneous deposition using Monte Carlo code simulations. Radiat. Protect. Dosim. 74:173-182; 1997.
    • (1997) Radiat. Protect. Dosim. , vol.74 , pp. 173-182
    • Kramer, G.H.1    Burns, L.C.2    Yiu, S.3
  • 8
    • 0024105319 scopus 로고
    • Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities
    • Shirotani, T. Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities. J. Nucl Sci. Tech. 25:875-883; 1988.
    • (1988) J. Nucl Sci. Tech. , vol.25 , pp. 875-883
    • Shirotani, T.1
  • 9
    • 0018361004 scopus 로고
    • Reference Japanese Man I - Mass of organs and other characteristics of normal Japanese
    • Tanaka, G.; Kawamura, H.; Nakahara, Y. Reference Japanese Man I - mass of organs and other characteristics of normal Japanese. Health Phys. 36:333-346; 1979.
    • (1979) Health Phys. , vol.36 , pp. 333-346
    • Tanaka, G.1    Kawamura, H.2    Nakahara, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.