메뉴 건너뛰기




Volumn 21, Issue 2, 1999, Pages 243-250

Urine fingerprinting: Detection of sample tampering in an opiate dependency program

Author keywords

Opiate dependency programs; Sample tampering; Urine fingerprinting

Indexed keywords

METHADONE; OPIATE;

EID: 0032951739     PISSN: 01634356     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007691-199904000-00017     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 0027862726 scopus 로고
    • Drug-testing methods and clinical interpretations of test results
    • Kapur BM. Drug-testing methods and clinical interpretations of test results. Bull Narc 1993;45:115-54.
    • (1993) Bull Narc , vol.45 , pp. 115-154
    • Kapur, B.M.1
  • 2
    • 0001776068 scopus 로고
    • Specimen adulteration in drug urine analysis
    • Cody JT. Specimen Adulteration in Drug Urine Analysis. Forensic Sci Rev 1990;2:64-74.
    • (1990) Forensic Sci Rev , vol.2 , pp. 64-74
    • Cody, J.T.1
  • 3
    • 0024209068 scopus 로고
    • Adulterants causing false negatives in illicit drug testing
    • Mikkelsen SL, Ash KO. Adulterants causing false negatives in illicit drug testing. Clin Chem 1988;34:2333-6.
    • (1988) Clin Chem , vol.34 , pp. 2333-2336
    • Mikkelsen, S.L.1    Ash, K.O.2
  • 4
    • 0030002851 scopus 로고    scopus 로고
    • The effect of glutaraldehyde adulteration of urine specimens on Syva EMIT II drugs-of-abuse assays
    • George S, Braithwaite RA. The effect of glutaraldehyde adulteration of urine specimens on Syva EMIT II drugs-of-abuse assays. J Anal Toxicol 1996;20:195-6.
    • (1996) J Anal Toxicol , vol.20 , pp. 195-196
    • George, S.1    Braithwaite, R.A.2
  • 5
    • 0028295833 scopus 로고
    • Hypochlorite adulteration of urine causing decreased concentration of delta 9-THC-COOH by GC/ MS
    • Baiker C, Serrano L, Lindner B. Hypochlorite adulteration of urine causing decreased concentration of delta 9-THC-COOH by GC/ MS. J Anal Toxicol 1994;18:101-3.
    • (1994) J Anal Toxicol , vol.18 , pp. 101-103
    • Baiker, C.1    Serrano, L.2    Lindner, B.3
  • 6
    • 0027291116 scopus 로고
    • Evaluation of common urine specimen adulteration indicators
    • Edwards C, Fyfe MJ, Liu RH, Walia AS. Evaluation of common urine specimen adulteration indicators. J Anal Toxicol 1993;17: 251-2.
    • (1993) J Anal Toxicol , vol.17 , pp. 251-252
    • Edwards, C.1    Fyfe, M.J.2    Liu, R.H.3    Walia, A.S.4
  • 7
    • 0027393807 scopus 로고
    • The effects of adulterating agents on FPIA analysis of urine for drugs of abuse
    • Schwarzhoff R, Cody JT. The effects of adulterating agents on FPIA analysis of urine for drugs of abuse. J Anal Toxicol 1993; 17:14-7.
    • (1993) J Anal Toxicol , vol.17 , pp. 14-17
    • Schwarzhoff, R.1    Cody, J.T.2
  • 8
    • 0025331639 scopus 로고
    • Intentional adulteration of urine specimens for drugs of abuse testing to produce false positive results
    • Johnson CA, Cary PL. Intentional adulteration of urine specimens for drugs of abuse testing to produce false positive results [letter]. J Anal Toxicol 1990;14:195-6.
    • (1990) J Anal Toxicol , vol.14 , pp. 195-196
    • Johnson, C.A.1    Cary, P.L.2
  • 9
    • 0024517277 scopus 로고
    • Interference of common household chemicals in immunoassay methods for drugs of abuse
    • Warner A. Interference of common household chemicals in immunoassay methods for drugs of abuse. Clin Chem 1989;35:648-51.
    • (1989) Clin Chem , vol.35 , pp. 648-651
    • Warner, A.1
  • 10
    • 0022273680 scopus 로고
    • EMIT tests for drugs of abuse: Interference by liquid soap preparations
    • Vu Duc T. EMIT tests for drugs of abuse: interference by liquid soap preparations. Clin Chem 1985;31:658-9.
    • (1985) Clin Chem , vol.31 , pp. 658-659
    • Vu Duc, T.1
  • 11
    • 0345243061 scopus 로고
    • Disorders of kidney and the urinary tract
    • Gornall AG, ed. Philadelphia: J.B. Lippencott Co.
    • Baines AD. Disorders of Kidney and the Urinary Tract. In: Gornall AG, ed. Applied Biochemistry of Clinical Disorders. Philadelphia: J.B. Lippencott Co. 1986;139-71.
    • (1986) Applied Biochemistry of Clinical Disorders , pp. 139-171
    • Baines, A.D.1
  • 12
    • 0026625335 scopus 로고
    • CEDIA in vitro diagnostics with a novel homogeneous immunoassay technique. Current status and future prospects
    • Engel WD, Khanna PL. CEDIA in vitro diagnostics with a novel homogeneous immunoassay technique. Current status and future prospects. J Immunol Methods 1992;150:99-102.
    • (1992) J Immunol Methods , vol.150 , pp. 99-102
    • Engel, W.D.1    Khanna, P.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.