메뉴 건너뛰기




Volumn 37, Issue 6, 1999, Pages 1709-1713

Controlled clinical comparison of bioMerieux VITAL and BACTEC NR-660 blood culture systems for detection of bacteremia and fungemia in adults

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AEROBIC BACTERIUM; ANAEROBIC BACTERIUM; ARTICLE; ASSAY; BACTEREMIA; BLOOD CULTURE; CONTAMINATION; CONTROLLED STUDY; FUNGEMIA; FUNGUS; GRAM NEGATIVE BACTERIUM; GRAM POSITIVE BACTERIUM; GRAM POSITIVE COCCI; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; MICROBIAL GROWTH; NONHUMAN; PRIORITY JOURNAL; SEPSIS; STAPHYLOCOCCUS AUREUS;

EID: 0032951605     PISSN: 00951137     EISSN: None     Source Type: Journal    
DOI: 10.1128/jcm.37.6.1709-1713.1999     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 0019919313 scopus 로고
    • Detection of yeasts and filamentous fungi in blood cultures during a 10-year period (1972-1981)
    • Bille, J. L., and G. D. Roberts. 1982. Detection of yeasts and filamentous fungi in blood cultures during a 10-year period (1972-1981). J. Clin Microbiol. 16:968-970.
    • (1982) J. Clin Microbiol. , vol.16 , pp. 968-970
    • Bille, J.L.1    Roberts, G.D.2
  • 2
    • 0003586480 scopus 로고    scopus 로고
    • Coordinating ed., J. Hindler, American Society for Microbiology, Washington, D.C.
    • Dunne, W. M., F. S. Nolte, and M. L. Wilson. 1997. Cumitech 1B. Blood cultures III. Coordinating ed., J. Hindler, American Society for Microbiology, Washington, D.C.
    • (1997) Cumitech 1B. Blood Cultures III
    • Dunne, W.M.1    Nolte, F.S.2    Wilson, M.L.3
  • 3
    • 0016278164 scopus 로고
    • Vacuum blood-culture bottles: Inhibiting growth of Candida and fostering growth of bacteroides
    • Gantz, N. M., A. A. Meideros, J. L. Swain, and T. F. O'Brien. 1974. Vacuum blood-culture bottles: inhibiting growth of Candida and fostering growth of bacteroides. Lancet ii:1174-1176.
    • (1974) Lancet , vol.2 , pp. 1174-1176
    • Gantz, N.M.1    Meideros, A.A.2    Swain, J.L.3    O'Brien, T.F.4
  • 4
    • 0016561867 scopus 로고
    • Effects of atmosphere of incubation and of routine subcultures on detection of bacteremia in vacuum blood culture bottles
    • Harkness, J. L., M. Hall, D. M. Ilstrup, and J. A. Washington II. 1975. Effects of atmosphere of incubation and of routine subcultures on detection of bacteremia in vacuum blood culture bottles. J. Clin. Microbiol. 2:296-299.
    • (1975) J. Clin. Microbiol. , vol.2 , pp. 296-299
    • Harkness, J.L.1    Hall, M.2    Ilstrup, D.M.3    Washington J.A. II4
  • 5
    • 0022632470 scopus 로고
    • Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system
    • Jungkind, D., J. Millan, S. Allen, J. Dyke, and E. Hill. 1986. Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system. J. Clin. Microbiol. 23:262-266.
    • (1986) J. Clin. Microbiol. , vol.23 , pp. 262-266
    • Jungkind, D.1    Millan, J.2    Allen, S.3    Dyke, J.4    Hill, E.5
  • 6
    • 0015920845 scopus 로고
    • Diminished growth of Pseudomonas aeruginosa in unvented blood-culture bottles
    • Knepper, J. G., and B. F. Anthony. 1973. Diminished growth of Pseudomonas aeruginosa in unvented blood-culture bottles. Lancet ii:285-287.
    • (1973) Lancet , vol.2 , pp. 285-287
    • Knepper, J.G.1    Anthony, B.F.2
  • 7
    • 0025896857 scopus 로고
    • Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system
    • Koontz, F. P., K. K. Flint, J. K. Reynolds, and S. D. Allen. 1991. Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system. Diagn. Microbiol. Infect. Dis. 14:111-118.
    • (1991) Diagn. Microbiol. Infect. Dis. , vol.14 , pp. 111-118
    • Koontz, F.P.1    Flint, K.K.2    Reynolds, J.K.3    Allen, S.D.4
  • 9
    • 0029055854 scopus 로고
    • Detection kinetics for positive blood culture bottles by using the VITAL automated system
    • Marchandin, H., B. Compan, M. S. De Buochberg, E. Despaux, and C, Perez. 1995. Detection kinetics for positive blood culture bottles by using the VITAL automated system. J. Clin. Microbiol. 33:2098-2101.
    • (1995) J. Clin. Microbiol. , vol.33 , pp. 2098-2101
    • Marchandin, H.1    Compan, B.2    De Buochberg, M.S.3    Despaux, E.4    Perez, C.5
  • 14
    • 0029986296 scopus 로고    scopus 로고
    • Comparison of BacT/Alert FAN medium with BACTEC NR660 plus 26A medium
    • Snyder, J. W., and S. K. Lude. 1996. Comparison of BacT/Alert FAN medium with BACTEC NR660 Plus 26A medium. J. Clin. Microbiol. 34:1327-1329.
    • (1996) J. Clin. Microbiol. , vol.34 , pp. 1327-1329
    • Snyder, J.W.1    Lude, S.K.2
  • 15
    • 0021963261 scopus 로고
    • Clinical comparison of an agar slide blood culture bottle with tryptic soy broth and a conventional blood culture bottle with supplemented peptone broth
    • Weinstein, M. P., L. B. Reller, S. Mirrett, W.-L. Wang, and D. V. Alcid. 1985. Clinical comparison of an agar slide blood culture bottle with tryptic soy broth and a conventional blood culture bottle with supplemented peptone broth. J. Clin. Microbiol. 21:815-818.
    • (1985) J. Clin. Microbiol. , vol.21 , pp. 815-818
    • Weinstein, M.P.1    Reller, L.B.2    Mirrett, S.3    Wang, W.-L.4    Alcid, D.V.5
  • 16
    • 0020690791 scopus 로고
    • The clinical significance of positive blood cultures: A comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations
    • Weinstein, M. P., L. B. Reller, J. R. Murphy, and K. A. Lichtenstein. 1983. The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations. Rev. Infect. Dis. 5:35-53.
    • (1983) Rev. Infect. Dis. , vol.5 , pp. 35-53
    • Weinstein, M.P.1    Reller, L.B.2    Murphy, J.R.3    Lichtenstein, K.A.4
  • 19
    • 0026529224 scopus 로고
    • Controlled comparison of BacT/Alert and BACTEC nonradiometric 660/730 blood culture systems
    • Wilson, M. L., M. P. Weinstein, L. G. Reimer, S. Mirrett, and L. B. Reller. 1992. Controlled comparison of BacT/Alert and BACTEC nonradiometric 660/730 blood culture systems. J. Clin. Microbiol. 30:323-329.
    • (1992) J. Clin. Microbiol. , vol.30 , pp. 323-329
    • Wilson, M.L.1    Weinstein, M.P.2    Reimer, L.G.3    Mirrett, S.4    Reller, L.B.5
  • 20
    • 0030611344 scopus 로고    scopus 로고
    • Controlled comparison of bioMérieux VITAL and BACTEC NR-660 blood culture systems for detection of bacteremia and fungemia in pediatric patients
    • Zaldi, A. K. M., S. Mirrett, J. C. McDonald, E. E. Rubin, L. C. McDonald, M. P. Weinstein, M. Gupta, and L. B. Reller. 1997. Controlled comparison of bioMérieux VITAL and BACTEC NR-660 blood culture systems for detection of bacteremia and fungemia in pediatric patients. J. Clin. Microbiol. 35:2007-2012.
    • (1997) J. Clin. Microbiol. , vol.35 , pp. 2007-2012
    • Zaldi, A.K.M.1    Mirrett, S.2    McDonald, J.C.3    Rubin, E.E.4    McDonald, L.C.5    Weinstein, M.P.6    Gupta, M.7    Reller, L.B.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.