메뉴 건너뛰기




Volumn 24, Issue 1, 1999, Pages 43-50

The PENCAN 25-gauge needle: A new pencil-point needle for spinal anesthesia tested in 1,193 patients

Author keywords

Failure rate; Pencil point needle; Postdural puncture complaints

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BLOOD AUTOTRANSFUSION; CEREBROSPINAL FLUID FLOW; CESAREAN SECTION; CLICK; FEMALE; HEADACHE; HUMAN; LUMBAR PUNCTURE; MAJOR CLINICAL STUDY; MALE; NEEDLE; OBESITY; PRIORITY JOURNAL; QUESTIONNAIRE; SPINAL ANESTHESIA; SPINE MALFORMATION; VISUAL DISORDER;

EID: 0032950421     PISSN: 0146521X     EISSN: None     Source Type: Journal    
DOI: 10.1016/s1098-7339(99)90164-5     Document Type: Article
Times cited : (15)

References (25)
  • 1
    • 0024356939 scopus 로고
    • Postdural puncture headache (PDPH): A review
    • M Gielen Postdural puncture headache (PDPH): A review Reg Anesth 14 1989 101 106
    • (1989) Reg Anesth , vol.14 , pp. 101-106
    • Gielen, M1
  • 2
    • 0028039093 scopus 로고
    • Postdural puncture headache and spinal needle design: Metaanalysis
    • S Halpern R Preston Postdural puncture headache and spinal needle design: Metaanalysis Anesthesiology 81 1994 1376 1383
    • (1994) Anesthesiology , vol.81 , pp. 1376-1383
    • Halpern, S1    Preston, R2
  • 3
    • 0026409229 scopus 로고
    • Use of a 25-gauge Whitacre needle to reduce the incidence of postdural puncture headache
    • J Lynch I Krings-Ernst K Strick K Topalidis H Schaaf M Fiebig Use of a 25-gauge Whitacre needle to reduce the incidence of postdural puncture headache Br J Anaesth 67 1991 690 693
    • (1991) Br J Anaesth , vol.67 , pp. 690-693
    • Lynch, J1    Krings-Ernst, I2    Strick, K3    Topalidis, K4    Schaaf, H5    Fiebig, M6
  • 4
    • 0026540097 scopus 로고
    • Spinal anesthesia for Caesarean section: Comparison of 22-gauge and 25-gauge Whitacre needles with 26-gauge Quincke needles
    • LE Shutt SJ Valentine MYK Wee RJ Page A Prosser TA Thomas Spinal anesthesia for Caesarean section: Comparison of 22-gauge and 25-gauge Whitacre needles with 26-gauge Quincke needles Br J Anaesth 69 1992 589 594
    • (1992) Br J Anaesth , vol.69 , pp. 589-594
    • Shutt, LE1    Valentine, SJ2    Wee, MYK3    Page, RJ4    Prosser, A5    Thomas, TA6
  • 5
    • 0027732916 scopus 로고
    • Comparison of the 25-gauge Whitacre with the 24-gauge Sprotte spinal needle for elective Caesarean section: Cost implications
    • DC Campbell MJ Douglas TJG Pavy P Merrick ML Flanagan GH McMorland Comparison of the 25-gauge Whitacre with the 24-gauge Sprotte spinal needle for elective Caesarean section: Cost implications Can J Anaesth 40 1993 1131 1135
    • (1993) Can J Anaesth , vol.40 , pp. 1131-1135
    • Campbell, DC1    Douglas, MJ2    Pavy, TJG3    Merrick, P4    Flanagan, ML5    McMorland, GH6
  • 6
    • 0028150658 scopus 로고
    • A comparison of 25 g and 27 g Whitacre needles for Caesarean section
    • EA Smith J Thorburn RA Duckworth JA Reid A comparison of 25 g and 27 g Whitacre needles for Caesarean section Anaesthesia 49 1994 859 862
    • (1994) Anaesthesia , vol.49 , pp. 859-862
    • Smith, EA1    Thorburn, J2    Duckworth, RA3    Reid, JA4
  • 7
    • 0029146359 scopus 로고
    • Comparison of 26-gauge Atraucan registered and 25-gauge Whitacre needles: Insertion characteristics and complications
    • SK Sharma DR Gambling GP Joshi JE Sidawi ER Herrera Comparison of 26-gauge Atraucan registered and 25-gauge Whitacre needles: Insertion characteristics and complications Can J Anaesth 42 1995 706 710
    • (1995) Can J Anaesth , vol.42 , pp. 706-710
    • Sharma, SK1    Gambling, DR2    Joshi, GP3    Sidawi, JE4    Herrera, ER5
  • 8
    • 0028057977 scopus 로고
    • Comparative flow rates of saline in commonly used spinal needles including pencil-tip needles
    • E Abouleish M Mitchell G Taylor H Miller D Warters MN Rashad Comparative flow rates of saline in commonly used spinal needles including pencil-tip needles Reg Anesth 19 1994 34 42
    • (1994) Reg Anesth , vol.19 , pp. 34-42
    • Abouleish, E1    Mitchell, M2    Taylor, G3    Miller, H4    Warters, D5    Rashad, MN6
  • 9
    • 0029030064 scopus 로고
    • Clinical characteristics of commonly used spinal needles
    • DF Carson MG Serpell Clinical characteristics of commonly used spinal needles Anaesthesia 50 1995 523 525
    • (1995) Anaesthesia , vol.50 , pp. 523-525
    • Carson, DF1    Serpell, MG2
  • 11
    • 0031052406 scopus 로고    scopus 로고
    • Flow dynamics through spinal needles
    • MG Serpell WM Gray Flow dynamics through spinal needles Anaesthesia 52 1997 229 236
    • (1997) Anaesthesia , vol.52 , pp. 229-236
    • Serpell, MG1    Gray, WM2
  • 12
    • 0025040867 scopus 로고
    • An evaluation of a 30-gauge needle for spinal anaesthesia for Caesarean section
    • P Lesser M Bembridge G Lyons R Macdonald An evaluation of a 30-gauge needle for spinal anaesthesia for Caesarean section Anaesthesia 45 1990 767 768
    • (1990) Anaesthesia , vol.45 , pp. 767-768
    • Lesser, P1    Bembridge, M2    Lyons, G3    Macdonald, R4
  • 13
    • 0026569836 scopus 로고
    • Postdural puncture headache in young orthopaedic in-patients: Comparison of a 0.33 mm (29-gauge) Quincke-type with a 0.7 mm (22-gauge) Whitacre spinal needle in 200 patients
    • J Lynch S Arhelger I Krings-Ernst Postdural puncture headache in young orthopaedic in-patients: Comparison of a 0.33 mm (29-gauge) Quincke-type with a 0.7 mm (22-gauge) Whitacre spinal needle in 200 patients Acta Anaesthesiol Scand 36 1992 58 61
    • (1992) Acta Anaesthesiol Scand , vol.36 , pp. 58-61
    • Lynch, J1    Arhelger, S2    Krings-Ernst, I3
  • 14
    • 0027963187 scopus 로고
    • Difficulties in spinal needle use
    • P Tarkkila J Huhtala U Salminen Difficulties in spinal needle use Insertion characteristics and failure rates associated with 25-, 27- and 29-gauge Quincke-type spinal needles Anaesthesia 49 1994 723 725
    • (1994) Anaesthesia , vol.49 , pp. 723-725
    • Tarkkila, P1    Huhtala, J2    Salminen, U3
  • 15
    • 0030907709 scopus 로고    scopus 로고
    • Hyperbaric dye solution distribution characteristics after pencil-point needle injection in a spinal cord model
    • SJ Holman RA Robinson D Beardsley SF Stewart L Klein RA Stevens Hyperbaric dye solution distribution characteristics after pencil-point needle injection in a spinal cord model Anesthesiology 86 1997 966 973
    • (1997) Anesthesiology , vol.86 , pp. 966-973
    • Holman, SJ1    Robinson, RA2    Beardsley, D3    Stewart, SF4    Klein, L5    Stevens, RA6
  • 16
    • 0029134006 scopus 로고
    • Transient neurologic deficit after spinal anesthesia: Local anesthetic maldistribution with pencil point needles?
    • D Beardsley S Holman R Gantt RA Robinson J Lindsey M Bazaral SF Stewart RA Stevens Transient neurologic deficit after spinal anesthesia: Local anesthetic maldistribution with pencil point needles? Anesth Analg 81 1995 314 320
    • (1995) Anesth Analg , vol.81 , pp. 314-320
    • Beardsley, D1    Holman, S2    Gantt, R3    Robinson, RA4    Lindsey, J5    Bazaral, M6    Stewart, SF7    Stevens, RA8
  • 17
    • 9044224765 scopus 로고    scopus 로고
    • The effects of needle type, gauge, and tip bend on spinal needle deflection
    • BT Sitzman DR Uncles The effects of needle type, gauge, and tip bend on spinal needle deflection Anesth Analg 82 1996 297 301
    • (1996) Anesth Analg , vol.82 , pp. 297-301
    • Sitzman, BT1    Uncles, DR2
  • 18
    • 0027980971 scopus 로고
    • Comparison of the force required for dural puncture with different spinal needles and subsequent leakage of cerebrospinal fluid
    • JL Westbrook DR Uncles BT Sitzman LES Carrie Comparison of the force required for dural puncture with different spinal needles and subsequent leakage of cerebrospinal fluid Anesth Analg 79 1994 769 772
    • (1994) Anesth Analg , vol.79 , pp. 769-772
    • Westbrook, JL1    Uncles, DR2    Sitzman, BT3    Carrie, LES4
  • 20
    • 0029059383 scopus 로고
    • Postdural puncture headache (PDPH): Onset, duration, severity, and associated symptoms
    • H Lybecker M Djernes JF Schmidt Postdural puncture headache (PDPH): Onset, duration, severity, and associated symptoms An analysis of 75 consecutive patients with PDPH Acta Anaesthesiol Scand 39 1995 605 612
    • (1995) Acta Anaesthesiol Scand , vol.39 , pp. 605-612
    • Lybecker, H1    Djernes, M2    Schmidt, JF3
  • 21
    • 0027318399 scopus 로고
    • Postdural puncture headache: Comparison of 25-gauge Whitacre and Quincke needles
    • J Buettner KP Wresch R Klose Postdural puncture headache: Comparison of 25-gauge Whitacre and Quincke needles Reg Anesth 18 1993 166 169
    • (1993) Reg Anesth , vol.18 , pp. 166-169
    • Buettner, J1    Wresch, KP2    Klose, R3
  • 22
    • 0031034463 scopus 로고    scopus 로고
    • Role of needle gauge and tip configuration in the production of lumbar puncture headache
    • DH Lambert RJ Hurley L Hertwig S Datta Role of needle gauge and tip configuration in the production of lumbar puncture headache Reg Anesth 22 1997 66 72
    • (1997) Reg Anesth , vol.22 , pp. 66-72
    • Lambert, DH1    Hurley, RJ2    Hertwig, L3    Datta, S4
  • 23
    • 0025025050 scopus 로고
    • Hearing loss after spinal anesthesia is related to needle size
    • J Fog LP Wang A Sundberg C Mucchiano Hearing loss after spinal anesthesia is related to needle size Anesth Analg 70 1990 517 522
    • (1990) Anesth Analg , vol.70 , pp. 517-522
    • Fog, J1    Wang, LP2    Sundberg, A3    Mucchiano, C4
  • 24
    • 0025826744 scopus 로고
    • Hearing loss following spinal anesthesia
    • O Michel T Brusis Hearing loss following spinal anesthesia Anaesth Reg Anesth 14 1991 92 95
    • (1991) Anaesth Reg Anesth , vol.14 , pp. 92-95
    • Michel, O1    Brusis, T2
  • 25
    • 0026806510 scopus 로고
    • The effect of epidural anaesthesia and size of spinal needle on post-operative hearing loss
    • S Oncel L Hasegeli MZ Uguz S Savaci K Onal S Oyman The effect of epidural anaesthesia and size of spinal needle on post-operative hearing loss J Laryngol Otol 106 1992 783 787
    • (1992) J Laryngol Otol , vol.106 , pp. 783-787
    • Oncel, S1    Hasegeli, L2    Uguz, MZ3    Savaci, S4    Onal, K5    Oyman, S6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.