메뉴 건너뛰기




Volumn 20, Issue 2, 1999, Pages 111-119

The effect of hydroxyapatite coating on bony ingrowth into grooved titanium implants

Author keywords

Cementless prosthesis; Hydroxyapatite coating; Porous coating; Surface macrotexture

Indexed keywords

BONE; PHOSPHATE COATINGS; PHOSPHATE MINERALS; POROUS MATERIALS; TEXTURES; TITANIUM ALLOYS;

EID: 0032950055     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(98)00011-8     Document Type: Article
Times cited : (53)

References (26)
  • 1
    • 0023471993 scopus 로고
    • The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant meterials
    • Thomas KA, Kay JF, Cook SD, Jarcho M. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant meterials. J Biomed Mater Res 1987;21:1395-414.
    • (1987) J Biomed Mater Res , vol.21 , pp. 1395-1414
    • Thomas, K.A.1    Kay, J.F.2    Cook, S.D.3    Jarcho, M.4
  • 2
    • 0023499767 scopus 로고
    • Chemical implant fixation using hydroxylapatite coatings
    • Geesink RGT, de Groot K, Christel PAKT. Chemical implant fixation using hydroxylapatite coatings. Clin Orthop 1987;225:147-70.
    • (1987) Clin Orthop , vol.225 , pp. 147-170
    • Geesink, R.G.T.1    De Groot, K.2    Christel, P.A.K.T.3
  • 4
    • 0025472956 scopus 로고
    • Breakdown corrosion potential of ceramic-coated metal implants
    • Hayashi K, Noda I, Uenoyama K, Sugioka Y. Breakdown corrosion potential of ceramic-coated metal implants. J Biomed Mater Res 1990;24:1111-3.
    • (1990) J Biomed Mater Res , vol.24 , pp. 1111-1113
    • Hayashi, K.1    Noda, I.2    Uenoyama, K.3    Sugioka, Y.4
  • 5
    • 0026140080 scopus 로고
    • Quantitative analysis of in vivo responses to titanium-oxide and hydroxyapatite-coated titanium alloy
    • Hayashi K, Uenoyama K, Matsuguchi N, Sugioka Y. Quantitative analysis of in vivo responses to titanium-oxide and hydroxyapatite-coated titanium alloy. J Biomed Mater Res 1991;25:515-23.
    • (1991) J Biomed Mater Res , vol.25 , pp. 515-523
    • Hayashi, K.1    Uenoyama, K.2    Matsuguchi, N.3    Sugioka, Y.4
  • 6
    • 0027605120 scopus 로고
    • Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants
    • Hayashi K, Inadome T, Mashima T, Sugioka Y. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants. J Biomed Mater Res 1993;27:557-63.
    • (1993) J Biomed Mater Res , vol.27 , pp. 557-563
    • Hayashi, K.1    Inadome, T.2    Mashima, T.3    Sugioka, Y.4
  • 7
    • 0028533742 scopus 로고
    • Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength
    • Hayashi K, Inadome T, Tsumura H, Nakashima Y, Sugioka Y. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. Biomaterials 1994;15:1187-91.
    • (1994) Biomaterials , vol.15 , pp. 1187-1191
    • Hayashi, K.1    Inadome, T.2    Tsumura, H.3    Nakashima, Y.4    Sugioka, Y.5
  • 8
    • 0026239712 scopus 로고
    • A mechanical investigation of fluoroapatite, magnesuim whitlockite, and hydroxyapatite plasma-sprayed coatings in goats
    • Dhert WJA, Klein CPAT, Wolke JGC, van der Velde EA, de Groot K. A mechanical investigation of fluoroapatite, magnesuim whitlockite, and hydroxyapatite plasma-sprayed coatings in goats. J Biomed Mater Res 1991;25:1183-200.
    • (1991) J Biomed Mater Res , vol.25 , pp. 1183-1200
    • Dhert, W.J.A.1    Klein, C.P.A.T.2    Wolke, J.G.C.3    Van Der Velde, E.A.4    De Groot, K.5
  • 9
    • 0026206791 scopus 로고
    • Histologic evaluation of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants
    • Jansen JA, van de Waerden JPCM, Wolke JGC, de Groot K. Histologic evaluation of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants. J Biomed Mater Res 1991;25:973-89.
    • (1991) J Biomed Mater Res , vol.25 , pp. 973-989
    • Jansen, J.A.1    Van De Waerden, J.P.C.M.2    Wolke, J.G.C.3    De Groot, K.4
  • 11
    • 0026580804 scopus 로고
    • Bioactive ceramic prosthetic coatings
    • Ducheyne P, Cuckler JM. Bioactive ceramic prosthetic coatings. Clin Orthop 1992;276:102-14.
    • (1992) Clin Orthop , vol.276 , pp. 102-114
    • Ducheyne, P.1    Cuckler, J.M.2
  • 13
    • 0028230087 scopus 로고
    • The influence of a hydroxyapatite and tricalcium- Phosphate coating on bone growth into titanium fiber-metal implants
    • Tisdel CL, Goldberg VM, Parr JA, Bensusan JS, Staikoff LS, Stevenson S. The influence of a hydroxyapatite and tricalcium- Phosphate coating on bone growth into titanium fiber-metal implants. J Bone Joint Surg 1994;76-A:159-71.
    • (1994) J Bone Joint Surg , vol.76 A , pp. 159-171
    • Tisdel, C.L.1    Goldberg, V.M.2    Parr, J.A.3    Bensusan, J.S.4    Staikoff, L.S.5    Stevenson, S.6
  • 14
    • 0028918271 scopus 로고
    • Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants
    • Inadome T, Hayashi K, Nakashima Y, Tsumura H, Sugioka Y. Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants. J Biomed Mater Res 1995;29:19-24.
    • (1995) J Biomed Mater Res , vol.29 , pp. 19-24
    • Inadome, T.1    Hayashi, K.2    Nakashima, Y.3    Tsumura, H.4    Sugioka, Y.5
  • 15
    • 0028874284 scopus 로고
    • The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants
    • Dalton JE, Cook SD, Thomas KA, Kay JF. The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants. J Bone Joint Surg 1995;77-A:97-110.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 97-110
    • Dalton, J.E.1    Cook, S.D.2    Thomas, K.A.3    Kay, J.F.4
  • 16
    • 0025608937 scopus 로고
    • Hydroxyapatite-coated total hip prostheses
    • Geesink RGT. Hydroxyapatite-coated total hip prostheses. Clin Orthop 1990;261:39-58.
    • (1990) Clin Orthop , vol.261 , pp. 39-58
    • Geesink, R.G.T.1
  • 18
    • 0026664139 scopus 로고
    • Hydroxyapatite coatings on hip prostheses: Effect on migration into the femur
    • Kroon P-O, Freeman MAR. Hydroxyapatite coatings on hip prostheses: Effect on migration into the femur. J Bone Joint Surg 1992;74-B:518-22.
    • (1992) J Bone Joint Surg , vol.74 B , pp. 518-522
    • Kroon, P.-O.1    Freeman, M.A.R.2
  • 21
    • 0029361094 scopus 로고
    • Characterization of thin hydroxyapatite layers formed on anodic titanium oxide films containing Ca and P by hydrothermal treatment
    • Ishizawa H, Ogino M. Characterization of thin hydroxyapatite layers formed on anodic titanium oxide films containing Ca and P by hydrothermal treatment. J Biomed Mater Res 1995;29:1071-9.
    • (1995) J Biomed Mater Res , vol.29 , pp. 1071-1079
    • Ishizawa, H.1    Ogino, M.2
  • 22
    • 0030298049 scopus 로고    scopus 로고
    • Preparation of bioactive Ti and its alloys via simple chemical surface treatment
    • Kim H-M, Miyaji F, Kokubo T, Nakamura T. Preparation of bioactive Ti and its alloys via simple chemical surface treatment. J Biomed Mater Res 1996;32:409-17.
    • (1996) J Biomed Mater Res , vol.32 , pp. 409-417
    • Kim, H.-M.1    Miyaji, F.2    Kokubo, T.3    Nakamura, T.4
  • 24
    • 0002199480 scopus 로고
    • Plasma spraying-induced changes of calcium phosphate ceramic characteristics and the effect on in vitro stability
    • Radin SR, Duchyne P. Plasma spraying-induced changes of calcium phosphate ceramic characteristics and the effect on in vitro stability. J Mater Sci: Mater in Med 1992;3:33-42.
    • (1992) J Mater Sci: Mater in Med , vol.3 , pp. 33-42
    • Radin, S.R.1    Duchyne, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.