메뉴 건너뛰기




Volumn 15, Issue 3, 1999, Pages 338-340

Avoiding graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction: A new technique

Author keywords

ACL reconstruction; Graft mismatch

Indexed keywords

ANTERIOR CRUCIATE LIGAMENT RUPTURE; ARTHROSCOPIC SURGERY; ARTICLE; BONE GRAFT; ENDOSCOPIC SURGERY; HUMAN; KNEE ARTHROPLASTY; KNEE ARTHROSCOPY; PATELLA TENDON; SURGICAL TECHNIQUE; TENDON GRAFT;

EID: 0032949779     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0749-8063(99)70047-2     Document Type: Article
Times cited : (15)

References (7)
  • 1
    • 0030632642 scopus 로고    scopus 로고
    • Pullout strength of tibial graft fixation in anterior cruciate ligament replacement with a patellar tendon graft: Interference screws versus staple fixation in human knees
    • TG Gerich A Cassim C Lattermann HP. Lobenhoffer Pullout strength of tibial graft fixation in anterior cruciate ligament replacement with a patellar tendon graft: Interference screws versus staple fixation in human knees Knee Surg Sports Traumatol Arthrosc 5 1997 84 88
    • (1997) Knee Surg Sports Traumatol Arthrosc , vol.5 , pp. 84-88
    • Gerich, TG1    Cassim, A2    Lattermann, C3    Lobenhoffer, HP.4
  • 2
    • 0027401896 scopus 로고
    • Endoscopic ACL reconstruction: A technical note on tunnel length for interference fixation
    • B Kenna TM Simon DW Jackson PR. Kurzweil Endoscopic ACL reconstruction: A technical note on tunnel length for interference fixation Arthroscopy 9 1993 228 230
    • (1993) Arthroscopy , vol.9 , pp. 228-230
    • Kenna, B1    Simon, TM2    Jackson, DW3    Kurzweil, PR.4
  • 3
    • 0030051840 scopus 로고    scopus 로고
    • The “N+7 Rule” for tibial tunnel placement in endoscopic anterior cruciate ligament reconstruction
    • MD Miller DT. Hinkin The “N+7 Rule” for tibial tunnel placement in endoscopic anterior cruciate ligament reconstruction Arthroscopy 12 1996 124 126
    • (1996) Arthroscopy , vol.12 , pp. 124-126
    • Miller, MD1    Hinkin, DT.2
  • 4
    • 0030842782 scopus 로고    scopus 로고
    • Difficulties with the “N=7 Rule” in endoscopic anterior cruciate ligament reconstruction
    • MW Pagnano C Kim G Hulie WN. Scott Difficulties with the “N=7 Rule” in endoscopic anterior cruciate ligament reconstruction Arthroscopy 13 1997 597 599
    • (1997) Arthroscopy , vol.13 , pp. 597-599
    • Pagnano, MW1    Kim, C2    Hulie, G3    Scott, WN.4
  • 5
    • 0031969037 scopus 로고    scopus 로고
    • Tibial tunnel bone grafting: A new technique for dealing with graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction
    • BL Fowler VJ. DiStefano Tibial tunnel bone grafting: A new technique for dealing with graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction Arthroscopy 14 1998 224 228
    • (1998) Arthroscopy , vol.14 , pp. 224-228
    • Fowler, BL1    DiStefano, VJ.2
  • 6
    • 0031886688 scopus 로고    scopus 로고
    • Ideal tibial tunnel length for endoscopic anterior cruciate ligament reconstruction
    • AD Olszewki MD Miller JR. Ritchie Ideal tibial tunnel length for endoscopic anterior cruciate ligament reconstruction Arthroscopy 14 1998 9 14
    • (1998) Arthroscopy , vol.14 , pp. 9-14
    • Olszewki, AD1    Miller, MD2    Ritchie, JR.3
  • 7
    • 0031967936 scopus 로고    scopus 로고
    • The effects of bone plug length and screw diameter on the holding strength of bone–patellar tendon–bone grafts
    • G Pomeroy M Baltz K Pierz M Nowak W Post JP. Fulkerson The effects of bone plug length and screw diameter on the holding strength of bone–patellar tendon–bone grafts Arthroscopy 14 1998 148 152
    • (1998) Arthroscopy , vol.14 , pp. 148-152
    • Pomeroy, G1    Baltz, M2    Pierz, K3    Nowak, M4    Post, W5    Fulkerson, JP.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.