메뉴 건너뛰기




Volumn 14, Issue 1, 1999, Pages 91-97

The effect of bone compaction on early fixation of porous-coated implants

Author keywords

Compaction; Fixation strength; Porous ingrowth

Indexed keywords

ANIMAL CELL; ANIMAL TISSUE; ARTICLE; BIOMECHANICS; BONE PROSTHESIS; BONE REGENERATION; BONE REMODELING; CANCELLOUS BONE; COMPRESSION; DOG; DRILL; FRACTURE FIXATION; IMPLANT; NONHUMAN; PROSTHESIS MATERIAL; RIGIDITY; SURGICAL TECHNIQUE;

EID: 0032949204     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(99)90208-5     Document Type: Article
Times cited : (66)

References (34)
  • 1
    • 72849167386 scopus 로고
    • Anchorage of the femoral head prosthesis to the shaft of the femur
    • Charnley J: Anchorage of the femoral head prosthesis to the shaft of the femur. J Bone Joint Surg Br 42:28, 1960
    • (1960) J Bone Joint Surg Br , vol.42 , pp. 28
    • Charnley, J.1
  • 2
    • 0003095948 scopus 로고
    • The elimination of the slip between prosthesis and femur
    • Charnley J, Kettlewell J: The elimination of the slip between prosthesis and femur. J Bone Joint Surg Br 47:56, 1965
    • (1965) J Bone Joint Surg Br , vol.47 , pp. 56
    • Charnley, J.1    Kettlewell, J.2
  • 3
    • 0023712327 scopus 로고
    • Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials
    • Collier JP, Mayor MBZ, Chae JC, et al: Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. Clin Orthop 235:173, 1988
    • (1988) Clin Orthop , vol.235 , pp. 173
    • Collier, J.P.1    Mayor, M.B.Z.2    Chae, J.C.3
  • 4
    • 0020524990 scopus 로고
    • Hip arthroplasty with a Moore prosthesis with porous coating: A five-year study
    • Engh CA: Hip arthroplasty with a Moore prosthesis with porous coating: a five-year study. Clin Orthop 176:52, 1983
    • (1983) Clin Orthop , vol.176 , pp. 52
    • Engh, C.A.1
  • 5
    • 0025179416 scopus 로고
    • Cementless total hip arthroplasty using the anatomic medullary locking stem: Results using a survivorship analysis
    • Engh CA, Massin P: Cementless total hip arthroplasty using the anatomic medullary locking stem: results using a survivorship analysis. Clin Orthop 257:107, 1990
    • (1990) Clin Orthop , vol.257 , pp. 107
    • Engh, C.A.1    Massin, P.2
  • 6
    • 0014983592 scopus 로고
    • Sintered fiber metal composites as a basis for attachment of implants to bone
    • Galante JO, Rostoker W, Lueck R, Ray RD: Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg Am 53:101, 1971
    • (1971) J Bone Joint Surg Am , vol.53 , pp. 101
    • Galante, J.O.1    Rostoker, W.2    Lueck, R.3    Ray, R.D.4
  • 7
    • 0027413687 scopus 로고
    • Impacted cancellous allografts and cement for revision total hip arthroplasty
    • Gie GA, Linder L, Ling RS, et al: Impacted cancellous allografts and cement for revision total hip arthroplasty. J Bone Joint Surg Br 75:14, 1993
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 14
    • Gie, G.A.1    Linder, L.2    Ling, R.S.3
  • 8
    • 0001455427 scopus 로고
    • The self locking metal hip prosthesis
    • Moore AT: The self locking metal hip prosthesis. J Bone Joint Surg Am 39:811, 1957
    • (1957) J Bone Joint Surg Am , vol.39 , pp. 811
    • Moore, A.T.1
  • 9
    • 0023766479 scopus 로고
    • Strategies for improving fixation of femoral components in total hip arthroplasty
    • Poss R, Walker P, Spector M, et al: Strategies for improving fixation of femoral components in total hip arthroplasty. Clin Orthop 235:181, 1988
    • (1988) Clin Orthop , vol.235 , pp. 181
    • Poss, R.1    Walker, P.2    Spector, M.3
  • 10
    • 0001620172 scopus 로고
    • Two and a half years' experience with a vitallium intramedullary hip prosthesis
    • Thompson FR: Two and a half years' experience with a vitallium intramedullary hip prosthesis. J Bone Joint Surg Am 36:489, 1954
    • (1954) J Bone Joint Surg Am , vol.36 , pp. 489
    • Thompson, F.R.1
  • 11
    • 0022490898 scopus 로고
    • Six year results with a micro-porous-coated metal hip prosthesis
    • Cameron HU: Six year results with a micro-porous-coated metal hip prosthesis. Clin Orthop 208:81, 1986
    • (1986) Clin Orthop , vol.208 , pp. 81
    • Cameron, H.U.1
  • 13
    • 0023759917 scopus 로고
    • Design and fabrication of cementless hip stems
    • Walker PS, Robertson DD: Design and fabrication of cementless hip stems. Clin Orthop 235:25, 1988
    • (1988) Clin Orthop , vol.235 , pp. 25
    • Walker, P.S.1    Robertson, D.D.2
  • 14
    • 0026527960 scopus 로고
    • Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty: A 12 year radiographic review
    • Barrack RL, Mulroy RD Jr, Harris WH: Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty: a 12 year radiographic review. J Bone Joint Surg Br 74:385, 1992
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 385
    • Barrack, R.L.1    Mulroy Jr., R.D.2    Harris, W.H.3
  • 15
    • 0021717803 scopus 로고
    • Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement
    • Burke DW, Gates EI, Harris WH: Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement. J Bone Joint Surg Am 66:1265, 1984
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 1265
    • Burke, D.W.1    Gates, E.I.2    Harris, W.H.3
  • 16
    • 0019957225 scopus 로고
    • Femoral component loosening using contemporary techniques of femoral cement fixation
    • Harris WH, McCarthy JC Jr, O'Neill DA: Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am 64:1063, 1982
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 1063
    • Harris, W.H.1    McCarthy Jr., J.C.2    O'Neill, D.A.3
  • 17
    • 0020044001 scopus 로고
    • A cement fixation system for total hip arthroplasty
    • Oh I, Harris WH: A cement fixation system for total hip arthroplasty. Clin Orthop 164:221, 1982
    • (1982) Clin Orthop , vol.164 , pp. 221
    • Oh, I.1    Harris, W.H.2
  • 18
    • 0028121998 scopus 로고
    • The femoral component in total hip arthroplasty, six to eight year follow up on one hundred consecutive patients after use of third generation cementing technique
    • Oishi CS, Walker RH, Colwell CW: The femoral component in total hip arthroplasty, six to eight year follow up on one hundred consecutive patients after use of third generation cementing technique. J Bone Joint Surg Am 76:1130, 1994
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1130
    • Oishi, C.S.1    Walker, R.H.2    Colwell, C.W.3
  • 19
    • 0027301351 scopus 로고
    • The outcome of Charnley total hip arthroplasty with cement after a minimum twenty year follow-up
    • Schulte KR, Callaghan JJ, Kelley SS, Johnston RC: The outcome of Charnley total hip arthroplasty with cement after a minimum twenty year follow-up. J Bone Joint Surg Am 75:961, 1993
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 961
    • Schulte, K.R.1    Callaghan, J.J.2    Kelley, S.S.3    Johnston, R.C.4
  • 21
    • 0027405754 scopus 로고
    • Current concepts review: The clinical results and basic science of total hip arthroplasty with porous-coated prostheses
    • Callahan JJ: Current concepts review: the clinical results and basic science of total hip arthroplasty with porous-coated prostheses. J Bone Joint Surg Am 75:299, 1993
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 299
    • Callahan, J.J.1
  • 22
    • 0023899919 scopus 로고
    • Implant fixation improved by close fit cylindrical implant-bone interface studied in the rabbit
    • Carlsson L, Rostlund T, Albrektsson B, Albrektsson T: Implant fixation improved by close fit cylindrical implant-bone interface studied in the rabbit. Acta Orthop Scand 59:272, 1988
    • (1988) Acta Orthop Scand , vol.59 , pp. 272
    • Carlsson, L.1    Rostlund, T.2    Albrektsson, B.3    Albrektsson, T.4
  • 23
    • 0019472503 scopus 로고
    • Radiographic and morphologic studies of load bearing porous-surfaced structured implants
    • Pillar RM, Cameron HU, Welsh RP, Binninton AG: Radiographic and morphologic studies of load bearing porous-surfaced structured implants. Clin Orthop 156:249, 1981
    • (1981) Clin Orthop , vol.156 , pp. 249
    • Pillar, R.M.1    Cameron, H.U.2    Welsh, R.P.3    Binninton, A.G.4
  • 24
    • 0015648310 scopus 로고
    • The effect of movement on the bonding of porous metal to bone
    • Cameron HU, Pillar RM, Macnab I: The effect of movement on the bonding of porous metal to bone. J Biomed Mater Res 7:301, 1973
    • (1973) J Biomed Mater Res , vol.7 , pp. 301
    • Cameron, H.U.1    Pillar, R.M.2    Macnab, I.3
  • 25
    • 0026336234 scopus 로고
    • The role of fixation and bone quality on the mechanical stability of tibial knee components
    • Lee RW, Volz RG, Sheridan DC: The role of fixation and bone quality on the mechanical stability of tibial knee components. Clin Orthop 273:177, 1991
    • (1991) Clin Orthop , vol.273 , pp. 177
    • Lee, R.W.1    Volz, R.G.2    Sheridan, D.C.3
  • 26
    • 0022465758 scopus 로고
    • Observations on the effect of movement on bone ingrowth into porous-surfaced implants
    • Pilliar RM, Lee JM, Maniatopoulos C: Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop 208:108, 1986
    • (1986) Clin Orthop , vol.208 , pp. 108
    • Pilliar, R.M.1    Lee, J.M.2    Maniatopoulos, C.3
  • 27
    • 0026832935 scopus 로고
    • Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Soballe K, Hansen ES, Rasmussen HB, et al: Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 10:285, 1992
    • (1992) J Orthop Res , vol.10 , pp. 285
    • Soballe, K.1    Hansen, E.S.2    Rasmussen, H.B.3
  • 28
    • 0029812483 scopus 로고    scopus 로고
    • Impaction autograft enhancement of femoral stem fixation in primary cementless THA
    • Keblish PA, Neufeld DK, Varma C: Impaction autograft enhancement of femoral stem fixation in primary cementless THA. Orthopedics 19:759, 1996
    • (1996) Orthopedics , vol.19 , pp. 759
    • Keblish, P.A.1    Neufeld, D.K.2    Varma, C.3
  • 29
    • 0026864024 scopus 로고
    • Efficacy of autograft and freeze-dried allograft to enhance fixation of porous coated implants in the presence of interface gaps
    • Kienapfel H, Sumner DR, Turner TM, et al: Efficacy of autograft and freeze-dried allograft to enhance fixation of porous coated implants in the presence of interface gaps. J Orthop Res 10:423, 1992
    • (1992) J Orthop Res , vol.10 , pp. 423
    • Kienapfel, H.1    Sumner, D.R.2    Turner, T.M.3
  • 30
    • 0026742314 scopus 로고
    • The influence of age, sex and initial fit on bony ingrowth stabilization with the AML femoral component in primary THA
    • Shaw JA, Bruno A, Paul EM: The influence of age, sex and initial fit on bony ingrowth stabilization with the AML femoral component in primary THA. Orthopedics 15:687, 1992
    • (1992) Orthopedics , vol.15 , pp. 687
    • Shaw, J.A.1    Bruno, A.2    Paul, E.M.3
  • 31
    • 0343229898 scopus 로고
    • Arthroscopically monitored ACL reconstruction: Compaction drilling and compression screw fixation
    • Feagin JA (ed): Churchill Livingstone, New York
    • Johnson LL, van Dyk EG: Arthroscopically monitored ACL reconstruction: compaction drilling and compression screw fixation. p. 555. In Feagin JA (ed): The crucial ligaments. 2nd ed. Churchill Livingstone, New York, 1994
    • (1994) The Crucial Ligaments. 2nd Ed. , pp. 555
    • Johnson, L.L.1    Van Dyk, E.G.2
  • 32
    • 0029809879 scopus 로고    scopus 로고
    • Metal and biodegradable interference screws: Comparison of failure strength
    • Johnson LL, vanDyk GE: Metal and biodegradable interference screws: comparison of failure strength. Arthroscopy 12:452, 1996
    • (1996) Arthroscopy , vol.12 , pp. 452
    • Johnson, L.L.1    VanDyk, G.E.2
  • 33
    • 0019435378 scopus 로고
    • Osteogenic phenomena across endosteal bone implant spaces with porous surfaced intramedullary implants
    • Bobyn HD, Piliar RM, Cameron HU, Weatherly GC: Osteogenic phenomena across endosteal bone implant spaces with porous surfaced intramedullary implants. Acta Orthop Scand 52:145, 1981
    • (1981) Acta Orthop Scand , vol.52 , pp. 145
    • Bobyn, H.D.1    Piliar, R.M.2    Cameron, H.U.3    Weatherly, G.C.4
  • 34
    • 13044291388 scopus 로고
    • Uer die innere architekur ker knoshen and ihire bedetung fur die frage von knochenwachstum
    • Wolff J: Uer die innere architekur ker knoshen and ihire bedetung fur die frage von knochenwachstum. Virchow Arch Klin Med 50:389, 1970
    • (1970) Virchow Arch Klin Med , vol.50 , pp. 389
    • Wolff, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.