Optimal energy filtering of the x-ray beam in cardiac angiography

Author keywords

Angiography; Filtering; Radiological exposure; X ray beam

Indexed keywords

GADOLINIUM;

EID: 0032945427     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (21)
  • 1
    • 0014807583 scopus 로고
    • Radiation dose to the patient in cardiac radiology
    • Ardan GM, Hamill J, Emrys Roberts E, Oliver R. Radiation dose to the patient in cardiac radiology. Br J Radiol 1970: 43 (510); 391-394.
    • (1970) Br J Radiol , vol.43 , Issue.510 , pp. 391-394
    • Ardan, G.M.1    Hamill, J.2    Emrys Roberts, E.3    Oliver, R.4
  • 2
    • 0018187325 scopus 로고
    • Physician and patient exposure during cardiac catheterization
    • Reuter FG. Physician and patient exposure during cardiac catheterization. Circulation 1978: 58 (1); 134-139.
    • (1978) Circulation , vol.58 , Issue.1 , pp. 134-139
    • Reuter, F.G.1
  • 3
    • 0018164241 scopus 로고
    • Chromosome damage in infants and children after cardiac catheterization and angiocardiography
    • Adams FH, Norman A, Bass D, Oku G. Chromosome damage in infants and children after cardiac catheterization and angiocardiography. Pediatrics 1978: 62 (3); 312-316.
    • (1978) Pediatrics , vol.62 , Issue.3 , pp. 312-316
    • Adams, F.H.1    Norman, A.2    Bass, D.3    Oku, G.4
  • 5
    • 0019511664 scopus 로고
    • Radiation exposure to the paediatric patient during cardiac catheterization and angiocardiography. Emphasis on the thyroid gland
    • Martin EC, Olson AP, Steeg CN, Casarella WJ, Radiation exposure to the paediatric patient during cardiac catheterization and angiocardiography. Emphasis on the thyroid gland. Circulation 1981: 64 (1); 153-158.
    • (1981) Circulation , vol.64 , Issue.1 , pp. 153-158
    • Martin, E.C.1    Olson, A.P.2    Steeg, C.N.3    Casarella, W.J.4
  • 8
    • 0019943903 scopus 로고
    • Reduction of radiation exposure in radiography of the chest
    • Rossi RP, Harnisch B, Hendee WR. Reduction of radiation exposure in radiography of the chest. Radiology 1982: 144; 909-914.
    • (1982) Radiology , vol.144 , pp. 909-914
    • Rossi, R.P.1    Harnisch, B.2    Hendee, W.R.3
  • 11
    • 0017876183 scopus 로고
    • Reduction of patient exposure by use of heavy elements as radiation filters in diagnostic radiology
    • Villagran JE, Hobbs BB, Taylor KW. Reduction of patient exposure by use of heavy elements as radiation filters in diagnostic radiology. Radiology 1978: 127; 249-258.
    • (1978) Radiology , vol.127 , pp. 249-258
    • Villagran, J.E.1    Hobbs, B.B.2    Taylor, K.W.3
  • 13
    • 0015364028 scopus 로고
    • Scattered radiation from a tissue-equivalent phantom for X-rays from 50 to 300 kVp
    • Trout ED, Kelley JP. Scattered radiation from a tissue-equivalent phantom for X-rays from 50 to 300 kVp. Radiology 1972: 104; 161-169.
    • (1972) Radiology , vol.104 , pp. 161-169
    • Trout, E.D.1    Kelley, J.P.2
  • 19
    • 0025806215 scopus 로고
    • Evaluation of the use of a Niobium filter for patient dose reduction in chest radiography
    • Thierens H, Kunnen M. Evaluation of the use of a Niobium filter for patient dose reduction in chest radiography. Br J Radiol 1991: 64; 334-340.
    • (1991) Br J Radiol , vol.64 , pp. 334-340
    • Thierens, H.1    Kunnen, M.2
  • 21
    • 0025668703 scopus 로고
    • The MRC200: A new high-output X-ray Tube
    • Behling R. The MRC200: a new high-output X-ray Tube. Medicamundi 1990: 35; 49-56.
    • (1990) Medicamundi , vol.35 , pp. 49-56
    • Behling, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.