메뉴 건너뛰기




Volumn 34, Issue 5, 1999, Pages 336-340

Technique for construction of an in vivo model of simulated pulmonary metastases

Author keywords

Animal models disease; Computed tomography; Pulmonary metastases; Pulmonary nodules

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DOG; LUNG METASTASIS; NONHUMAN; PRIORITY JOURNAL; SIMULATION;

EID: 0032941641     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199905000-00002     Document Type: Article
Times cited : (2)

References (20)
  • 1
    • 0024039620 scopus 로고
    • Significance of pulmonary computed tomography at diagnosis in Wilm's tumor
    • William JA, Douglass EC, Magill HL, Fitch S, Husto O. Significance of pulmonary computed tomography at diagnosis in Wilm's tumor. J Clin Oncol 1988;6:1144-1146.
    • (1988) J Clin Oncol , vol.6 , pp. 1144-1146
    • William, J.A.1    Douglass, E.C.2    Magill, H.L.3    Fitch, S.4    Husto, O.5
  • 3
    • 0026099066 scopus 로고
    • Pulmonary metastases and bone sarcomas: Surgical removal of lesions appearing after chemotherapy
    • Burk CD, Belasco JB, O'Neill J, Lange B. Pulmonary metastases and bone sarcomas: Surgical removal of lesions appearing after chemotherapy. Clin Orthop 1991;262:88-92.
    • (1991) Clin Orthop , vol.262 , pp. 88-92
    • Burk, C.D.1    Belasco, J.B.2    O'Neill, J.3    Lange, B.4
  • 4
    • 0028965019 scopus 로고
    • Systemic relapse of patients with osteogenic sarcoma: Prognostic factors for long-term survival
    • Saeter G, Hoie J, Stenwig AE, Johansson AK, Hannisdal E, Solheim OP. Systemic relapse of patients with osteogenic sarcoma: Prognostic factors for long-term survival. Cancer 1995;75(5):1084-1093.
    • (1995) Cancer , vol.75 , Issue.5 , pp. 1084-1093
    • Saeter, G.1    Hoie, J.2    Stenwig, A.E.3    Johansson, A.K.4    Hannisdal, E.5    Solheim, O.P.6
  • 5
    • 0025695318 scopus 로고
    • Paediatric osteosarcoma: Therapeutic strategies, results and prognostic factors derived from a ten-year experience
    • Hudson M, Jaffe MR Jaffe N, et al. Paediatric osteosarcoma: Therapeutic strategies, results and prognostic factors derived from a ten-year experience. J Clin Oncol 1990;8(12):1988-1997.
    • (1990) J Clin Oncol , vol.8 , Issue.12 , pp. 1988-1997
    • Hudson, M.1    Jaffe, M.R.2    Jaffe, N.3
  • 7
    • 0031903431 scopus 로고    scopus 로고
    • Effect of breathing on the detection of in vivo simulated pulmonary nodules by spiral CT
    • Coakley FV, Cohen MD, Johnson MS, Gonin R, Hanna MP. Effect of breathing on the detection of in vivo simulated pulmonary nodules by spiral CT. Clin Radiol 1998;53:506-509.
    • (1998) Clin Radiol , vol.53 , pp. 506-509
    • Coakley, F.V.1    Cohen, M.D.2    Johnson, M.S.3    Gonin, R.4    Hanna, M.P.5
  • 8
    • 0031909570 scopus 로고    scopus 로고
    • Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT
    • Coakley FV, Cohen MD, Johnson MS, Gonin R, Hanna MP. Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT. Br J Radiol 1998;71:135-140.
    • (1998) Br J Radiol , vol.71 , pp. 135-140
    • Coakley, F.V.1    Cohen, M.D.2    Johnson, M.S.3    Gonin, R.4    Hanna, M.P.5
  • 10
    • 0028279872 scopus 로고
    • Spiral CT of the lungs: Optimal technique and resolution compared with conventional CT
    • Paranjpe DV, Bergin CJ. Spiral CT of the lungs: Optimal technique and resolution compared with conventional CT. AJR 1994;162: 561-567.
    • (1994) AJR , vol.162 , pp. 561-567
    • Paranjpe, D.V.1    Bergin, C.J.2
  • 11
    • 0008345604 scopus 로고    scopus 로고
    • The detection of pulmonary metastases with pathological correlation in a canine model: Effect of breathing on the accuracy of spiral CT
    • Coakley FV, Cohen MD, Waters DJ, et al. The detection of pulmonary metastases with pathological correlation in a canine model: Effect of breathing on the accuracy of spiral CT. AJR 1997;169:1615-16618.
    • (1997) AJR , vol.169 , pp. 1615-16618
    • Coakley, F.V.1    Cohen, M.D.2    Waters, D.J.3
  • 12
    • 0021082657 scopus 로고
    • A standard phantom for quantitative analysis of pulmonary nodules
    • Zerhouni EA, Boukadoum M, Siddiky MA, et al. A standard phantom for quantitative analysis of pulmonary nodules. Radiology 1993; 149:767-773.
    • (1993) Radiology , vol.149 , pp. 767-773
    • Zerhouni, E.A.1    Boukadoum, M.2    Siddiky, M.A.3
  • 14
    • 0028217012 scopus 로고
    • Comparison of spiral-acquisition computed tomography and conventional computed tomography in the assessment of pulmonary metastatic disease
    • Collie DA, Wright AR, Williams JR, Hashemi-Malayeri, Stevenson AJM, Turnbull CM. Comparison of spiral-acquisition computed tomography and conventional computed tomography in the assessment of pulmonary metastatic disease. Br J Radiol 1994;67:436-444.
    • (1994) Br J Radiol , vol.67 , pp. 436-444
    • Collie, D.A.1    Wright, A.R.2    Williams, J.R.3    Stevenson, A.J.M.4    Turnbull, C.M.5
  • 15
    • 0001296249 scopus 로고
    • Spiral CT of pulmonary nodules: Comparison of 2:1 and 1:1 pitch
    • Funke M, Kopka L, Fischer U, Oestman JW, Grabbe EH. Spiral CT of pulmonary nodules: Comparison of 2:1 and 1:1 pitch. Radiology 1994;193(P):339.
    • (1994) Radiology , vol.193 , Issue.P , pp. 339
    • Funke, M.1    Kopka, L.2    Fischer, U.3    Oestman, J.W.4    Grabbe, E.H.5
  • 16
    • 0345101329 scopus 로고
    • Sensitivity for standard and helical CT scanning
    • Jacobson DJ, Metz SW, Foley WD. Sensitivity for standard and helical CT scanning. Radiology 1993;189(P):238.
    • (1993) Radiology , vol.189 , Issue.P , pp. 238
    • Jacobson, D.J.1    Metz, S.W.2    Foley, W.D.3
  • 17
    • 0027368254 scopus 로고
    • Spiral volumetric CT as a routine technique for thoracic imaging
    • Watanabe H, Nakata H, Egashira K, Nakamura K. Spiral volumetric CT as a routine technique for thoracic imaging. J Thorac Imag 1993;8:316-320.
    • (1993) J Thorac Imag , vol.8 , pp. 316-320
    • Watanabe, H.1    Nakata, H.2    Egashira, K.3    Nakamura, K.4
  • 18
    • 0028787508 scopus 로고
    • Pulmonary nodules: Improved detection with vascular segmentation and extraction with spiral CT
    • Croisille P, Suoto M, Cova M, et al. Pulmonary nodules: Improved detection with vascular segmentation and extraction with spiral CT. Radiology 1995;197:397-401.
    • (1995) Radiology , vol.197 , pp. 397-401
    • Croisille, P.1    Suoto, M.2    Cova, M.3
  • 19
    • 0027366655 scopus 로고
    • Variables affecting pulmonary nodule detection with computed tomography: Evaluation with three-dimensional computer simulation
    • Naidich DP, Rusinek H, McGuinness G, Leitman B, McCauley DI, Henschke CI. Variables affecting pulmonary nodule detection with computed tomography: Evaluation with three-dimensional computer simulation. J Thorac Imag 1993:8:291-299.
    • (1993) J Thorac Imag , vol.8 , pp. 291-299
    • Naidich, D.P.1    Rusinek, H.2    McGuinness, G.3    Leitman, B.4    McCauley, D.I.5    Henschke, C.I.6
  • 20
    • 0017155081 scopus 로고
    • The effects of biological motion on CT resolution
    • Alfidi RJ, MacIntyre WJ, Haaga JR. The effects of biological motion on CT resolution. AJR 1976;127:11-15.
    • (1976) AJR , vol.127 , pp. 11-15
    • Alfidi, R.J.1    MacIntyre, W.J.2    Haaga, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.