메뉴 건너뛰기




Volumn 14, Issue 1, 1999, Pages 14-17

Electrolyte monitoring in patients undergoing peripheral blood stem cell collection

Author keywords

Hypocalcemia; Hypokalemia; Side effects; Therapeutic apheresis

Indexed keywords

CALCIUM ION; MAGNESIUM ION; POTASSIUM ION;

EID: 0032940790     PISSN: 07332459     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1098-1101(1999)14:1<14::AID-JCA3>3.0.CO;2-E     Document Type: Article
Times cited : (8)

References (18)
  • 2
    • 0028877585 scopus 로고
    • Collection and use of circulating hematopoietic progenitor cells
    • Lee JH, Klein HG. Collection and use of circulating hematopoietic progenitor cells. Hematol Oncol Clin North Am 1995;9/1:1-22.
    • (1995) Hematol Oncol Clin North Am , vol.9 , Issue.1 , pp. 1-22
    • Lee, J.H.1    Klein, H.G.2
  • 4
    • 0346676906 scopus 로고    scopus 로고
    • Comparison of performance of six different cell separators in collecting peripheral blood mono-nuclear cells
    • Bellavita P, Celega E, Poma R. Comparison of performance of six different cell separators in collecting peripheral blood mono-nuclear cells. Transfus Sci 1997;18/2:215-221.
    • (1997) Transfus Sci , vol.18 , Issue.2 , pp. 215-221
    • Bellavita, P.1    Celega, E.2    Poma, R.3
  • 5
    • 0024361349 scopus 로고
    • Complications of plasma-exchange
    • Sutton DMC, Nair RC, Rock G, and the Canadian apheresis study group. Complications of plasma-exchange. Transfusion 1989;29: 124-127.
    • (1989) Transfusion , vol.29 , pp. 124-127
    • Sutton, D.M.C.1    Nair, R.C.2    Rock, G.3
  • 6
    • 0029834417 scopus 로고    scopus 로고
    • Mechanism of adverse effects during hemapheresis
    • Strauss RG. Mechanism of adverse effects during hemapheresis. J Clin Apheresis 1996;11:160-164.
    • (1996) J Clin Apheresis , vol.11 , pp. 160-164
    • Strauss, R.G.1
  • 7
    • 0030950507 scopus 로고    scopus 로고
    • Importance of ionized magnesium measurement for monitoring of citrate-anticoagulated plateletpheresis
    • Mercan D, Bastin G, Lambermont M, Dupont E. Importance of ionized magnesium measurement for monitoring of citrate-anticoagulated plateletpheresis. Transfusion 1997;37:418-422.
    • (1997) Transfusion , vol.37 , pp. 418-422
    • Mercan, D.1    Bastin, G.2    Lambermont, M.3    Dupont, E.4
  • 9
    • 8244220327 scopus 로고    scopus 로고
    • Angina pectoris occurring during granulocyte colony-stimulating factor-combined preparatory regimen for autologous peripheral blood stem cell transplantation in a patient with acute myelogenous leukemia
    • Fukumoto Y, Miyamoto T, Okamura T, Gondo H, Iwasaki H, Horiuchi T, Yoshizawa S, Inaba S, Harada M, Niho Y. Angina pectoris occurring during granulocyte colony-stimulating factor-combined preparatory regimen for autologous peripheral blood stem cell transplantation in a patient with acute myelogenous leukemia. Br J Haematol 1997;97:666-668.
    • (1997) Br J Haematol , vol.97 , pp. 666-668
    • Fukumoto, Y.1    Miyamoto, T.2    Okamura, T.3    Gondo, H.4    Iwasaki, H.5    Horiuchi, T.6    Yoshizawa, S.7    Inaba, S.8    Harada, M.9    Niho, Y.10
  • 11
    • 0030902249 scopus 로고    scopus 로고
    • Safety of large-volume leukapheresis for collection of peripheral blood progenitor cells
    • Reik RA, Noto TA, Fernandez HF. Safety of large-volume leukapheresis for collection of peripheral blood progenitor cells. J Clin Apheresis 1997;12:10-13.
    • (1997) J Clin Apheresis , vol.12 , pp. 10-13
    • Reik, R.A.1    Noto, T.A.2    Fernandez, H.F.3
  • 13
    • 0023708128 scopus 로고
    • Abnormal electrocardiographic findings in apheresis donors
    • Komatsu F, Shikata M. Abnormal electrocardiographic findings in apheresis donors. Transfusion 1988;28:371-374.
    • (1988) Transfusion , vol.28 , pp. 371-374
    • Komatsu, F.1    Shikata, M.2
  • 14
    • 0031154958 scopus 로고    scopus 로고
    • Comments on the kinetics and extracellular effects of potassium and magnesium
    • Vierling W. Comments on the kinetics and extracellular effects of potassium and magnesium. Herz 1997;22/1:3-10.
    • (1997) Herz , vol.22 , Issue.1 , pp. 3-10
    • Vierling, W.1
  • 15
    • 0029934898 scopus 로고    scopus 로고
    • Acute arterial thrombosis due to platelet aggregation in a patient receiving granulocyte colony-stimulating factor
    • Kawachi M, Watanabe A, Uchida T, Yoshizawa K, Kurooka N, Setsu K. Acute arterial thrombosis due to platelet aggregation in a patient receiving granulocyte colony-stimulating factor, Br J Haematol 1996;94:413-416.
    • (1996) Br J Haematol , vol.94 , pp. 413-416
    • Kawachi, M.1    Watanabe, A.2    Uchida, T.3    Yoshizawa, K.4    Kurooka, N.5    Setsu, K.6
  • 16
    • 0022835194 scopus 로고
    • Silent myocardial ischemia: Definition, magnitude, and scope of the problem
    • Pepine CJ. Silent myocardial ischemia: definition, magnitude, and scope of the problem. Cardiol Clin 1986;4:577-581.
    • (1986) Cardiol Clin , vol.4 , pp. 577-581
    • Pepine, C.J.1
  • 17
    • 0025261245 scopus 로고
    • Silent myocardial ischemia in a patient with anemia before operation
    • Parsloe MRJ, Wyld R, Fox M, Reilly CS. Silent myocardial ischemia in a patient with anemia before operation. Br J Anaesth 1990; 64:634-637.
    • (1990) Br J Anaesth , vol.64 , pp. 634-637
    • Parsloe, M.R.J.1    Wyld, R.2    Fox, M.3    Reilly, C.S.4
  • 18
    • 0345019421 scopus 로고
    • Fluid and electrolyte problems
    • Tintinalli JE, Krone RL, Ruiz E, editors. New York: McGraw Hill
    • Wilson RF. Fluid and electrolyte problems. In: Tintinalli JE, Krone RL, Ruiz E, editors. Emergency medicine. New York: McGraw Hill; 1992. p 62-85.
    • (1992) Emergency Medicine , pp. 62-85
    • Wilson, R.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.