Dose and image quality of electron-beam CT compared with spiral CT

Author keywords

CT, electron beam; CT, helical; CT, radiation exposure

Indexed keywords

ARTICLE; ELECTRON BEAM TOMOGRAPHY; IMAGE QUALITY; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; RADIATION HAZARD; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 0032936974     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199906000-00005     Document Type: Article
Times cited : (16)

References (7)
  • 1
    • 0028147743 scopus 로고
    • The measurement of radiation dose profiles for electron-beam computed tomography using film dosimetry
    • Zink FE, McCollough CH. The measurement of radiation dose profiles for electron-beam computed tomography using film dosimetry. Med Phys 1994;21(8):1287-1291.
    • (1994) Med Phys , vol.21 , Issue.8 , pp. 1287-1291
    • Zink, F.E.1    McCollough, C.H.2
  • 2
    • 0029058595 scopus 로고
    • Breast dose during electron-beam CT: Measurement with film dosimetry
    • McCollough CH, Liu HH. Breast dose during electron-beam CT: Measurement with film dosimetry. Radiology 1995;196:153-157.
    • (1995) Radiology , vol.196 , pp. 153-157
    • McCollough, C.H.1    Liu, H.H.2
  • 3
    • 0028893476 scopus 로고
    • Computed tomography dose assessment - A practical approach
    • Leitz W, Axelsson B, Szendro G. Computed tomography dose assessment - a practical approach. Rad Prot Dos 1995;57:377-380.
    • (1995) Rad Prot Dos , vol.57 , pp. 377-380
    • Leitz, W.1    Axelsson, B.2    Szendro, G.3
  • 4
    • 0028041033 scopus 로고
    • Radiation dosimetry for electron beam CT
    • McCollough CH, Zink FE, Morin RL. Radiation dosimetry for electron beam CT. Radiology 1994;192:637-643.
    • (1994) Radiology , vol.192 , pp. 637-643
    • McCollough, C.H.1    Zink, F.E.2    Morin, R.L.3
  • 5
    • 0031856447 scopus 로고    scopus 로고
    • Radiation dose and image quality in spiral computed tomography: Multicentre evaluation at six institutions
    • Scheck RJ, Coppenrath EM, Kellner MW, et al. Radiation dose and image quality in spiral computed tomography: Multicentre evaluation at six institutions. Br J Radiol 1998;71:734-744.
    • (1998) Br J Radiol , vol.71 , pp. 734-744
    • Scheck, R.J.1    Coppenrath, E.M.2    Kellner, M.W.3
  • 6
    • 0027955501 scopus 로고
    • Measurement of slice sensitivity profiles in spiral CT
    • Polacin A, Kalender WA, Brink J, Vannier MA. Measurement of slice sensitivity profiles in spiral CT. Med Phys 1994;21(1):133-140.
    • (1994) Med Phys , vol.21 , Issue.1 , pp. 133-140
    • Polacin, A.1    Kalender, W.A.2    Brink, J.3    Vannier, M.A.4
  • 7
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission for x-ray computed tomography
    • Shope TB, Gagne RM, Johnson GC. A method for describing the doses delivered by transmission for x-ray computed tomography. Med Phys 1981;8:488-495.
    • (1981) Med Phys , vol.8 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.