메뉴 건너뛰기




Volumn 9, Issue 3, 1999, Pages 369-372

MRI of liver metastases: Limitation of spleen-liver model in optimizing pulse sequences

Author keywords

Liver; Liver metastases; Magnetic resonance (MR); Pulse sequences; Spleen

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COLORECTAL CANCER; FEMALE; HUMAN; IMAGE PROCESSING; LIVER METASTASIS; LIVER SCINTISCANNING; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIGNAL NOISE RATIO; SPIN LABELING;

EID: 0032935322     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(199903)9:3<369::AID-JMRI1>3.0.CO;2-H     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 0022569108 scopus 로고
    • Detection of hepatic metastases: Analysis of pulse sequence performance in MR imaging
    • Stark DD, Wittenberg J, Edelman RR, et al. Detection of hepatic metastases: analysis of pulse sequence performance in MR imaging. Radiology 1986;159:365-370.
    • (1986) Radiology , vol.159 , pp. 365-370
    • Stark, D.D.1    Wittenberg, J.2    Edelman, R.R.3
  • 2
    • 0025744303 scopus 로고
    • T1-weighted sequences for MR imaging of the liver: Comparison of three techniques for single-breath, whole-volume acquisition at 1.0 and 1.5T
    • Semelka RC, Simm FC, Recht M, Deimling M, Lenz G, Laub GA. T1-weighted sequences for MR imaging of the liver: comparison of three techniques for single-breath, whole-volume acquisition at 1.0 and 1.5T. Radiology 1991;180:629-635.
    • (1991) Radiology , vol.180 , pp. 629-635
    • Semelka, R.C.1    Simm, F.C.2    Recht, M.3    Deimling, M.4    Lenz, G.5    Laub, G.A.6
  • 3
    • 0028816042 scopus 로고
    • T2-weighted breath-hold MR imaging of the liver at 1.5 T: Results with a three-dimensional steady-state free precession sequence in 87 patients
    • Taupitz M, Speidel A, Hamm B, et al. T2-weighted breath-hold MR imaging of the liver at 1.5 T: results with a three-dimensional steady-state free precession sequence in 87 patients. Radiology 1995;194:439-446.
    • (1995) Radiology , vol.194 , pp. 439-446
    • Taupitz, M.1    Speidel, A.2    Hamm, B.3
  • 5
    • 0025991468 scopus 로고
    • MR imaging of liver metastases at 1.5 T: Similar contrast discrimination with T1-and T2-weighted pulse sequences
    • Saini S, Li W, Wallner B, Hahn PF, Edelman RR. MR imaging of liver metastases at 1.5 T: similar contrast discrimination with T1-and T2-weighted pulse sequences. Radiology 1991;181:449-453.
    • (1991) Radiology , vol.181 , pp. 449-453
    • Saini, S.1    Li, W.2    Wallner, B.3    Hahn, P.F.4    Edelman, R.R.5
  • 6
    • 0030021798 scopus 로고    scopus 로고
    • T2-weighted spin-echo MR imaging of the liver: Breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression
    • Soyer P, Le Normand S, de Givry SC, Gueye C, Somveille E, Scherrer A. T2-weighted spin-echo MR imaging of the liver: breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression. AJR 1996;166:593-597.
    • (1996) AJR , vol.166 , pp. 593-597
    • Soyer, P.1    Le Normand, S.2    De Givry, S.C.3    Gueye, C.4    Somveille, E.5    Scherrer, A.6
  • 7
    • 0011222637 scopus 로고
    • Evaluation of turbo spin echo sequences for MRI of focal liver lesions at 0.5 T.
    • Kreft B, Layer G, Steudel A, et al. Evaluation of turbo spin echo sequences for MRI of focal liver lesions at 0.5 T. Eur Radiol 1994;4:106-113.
    • (1994) Eur Radiol , vol.4 , pp. 106-113
    • Kreft, B.1    Layer, G.2    Steudel, A.3
  • 8
    • 0028204966 scopus 로고
    • MR imaging of the liver: Breath-hold T1-weighted MP-GRE compared with conventional T2-weighted SE imaging - Lesion detection, localization, and characterization
    • de Lange EE, Mugler 3rd JP, Bosworth JE, et al. MR imaging of the liver: breath-hold T1-weighted MP-GRE compared with conventional T2-weighted SE imaging - lesion detection, localization, and characterization. Radiology 1994;190:727-736.
    • (1994) Radiology , vol.190 , pp. 727-736
    • De Lange, E.E.1    Mugler J.P. III2    Bosworth, J.E.3
  • 9
    • 0344857140 scopus 로고
    • Measurement of signal, noise and SNR in MR images
    • Hendrick RE, Russ PD, Simon JH, editors. New York: Raven Press
    • Hendrick RE. Measurement of signal, noise and SNR in MR images. In: Hendrick RE, Russ PD, Simon JH, editors. MRI: principles and artifacts. New York: Raven Press; 1988. p 2-6.
    • (1988) MRI: Principles and Artifacts , pp. 2-6
    • Hendrick, R.E.1
  • 10
    • 0027957235 scopus 로고
    • Abdominal MR imaging: Evaluation of a fast spin-echo sequence
    • Outwater EK, Mitchell DG, Vinitski S. Abdominal MR imaging: evaluation of a fast spin-echo sequence. Radiology 1994;190:425-429.
    • (1994) Radiology , vol.190 , pp. 425-429
    • Outwater, E.K.1    Mitchell, D.G.2    Vinitski, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.