메뉴 건너뛰기




Volumn 8, Issue 1, 1999, Pages 57-61

Diagnosis of thrombus and blood flow in aortic aneurysm using tagging cine magnetic resonance imaging

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; AORTA ANEURYSM; AORTA ARCH; AORTA DISSECTION; AORTA FLOW; AORTA THROMBOSIS; ARTICLE; CINERADIOGRAPHY; CLINICAL ARTICLE; CLINICAL TRIAL; FEMALE; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0032931895     PISSN: 10611711     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF01616845     Document Type: Article
Times cited : (9)

References (14)
  • 1
    • 0027959898 scopus 로고
    • Evaluation of short axial blood flow pattern in thoracic descending aorta by use of tagging cine magnetic resonance
    • 1. Matsumoto Y, Honda T, Hamada M, et al (1994) Evaluation of short axial blood flow pattern in thoracic descending aorta by use of tagging cine magnetic resonance. Angiology 45:917-922.
    • (1994) Angiology , vol.45 , pp. 917-922
    • Matsumoto, Y.1    Honda, T.2    Hamada, M.3
  • 2
    • 0019143159 scopus 로고
    • CT patterns of mural thrombus in aortic aneurysms
    • 2. Machida K, Tasaka A (1980) CT patterns of mural thrombus in aortic aneurysms. J Comput Assist Tomogr 4:840-842.
    • (1980) J Comput Assist Tomogr , vol.4 , pp. 840-842
    • Machida, K.1    Tasaka, A.2
  • 3
    • 0023142250 scopus 로고
    • Pre-operative evaluation of abdominal aortic aneurysms: Ultrasound or computed tomography?
    • 3. Gomes MN, Choyke PL (1987) Pre-operative evaluation of abdominal aortic aneurysms: Ultrasound or computed tomography? J Cardiovasc Surg 28:159-166.
    • (1987) J Cardiovasc Surg , vol.28 , pp. 159-166
    • Gomes, M.N.1    Choyke, P.L.2
  • 5
    • 0023896127 scopus 로고
    • Computed tomography of abdominal aortic aneurysm: An in vivo pathological report with a note on dynamic predictors
    • 5. Pillari G, Chang JB, Zito J, et al (1989) Computed tomography of abdominal aortic aneurysm: An in vivo pathological report with a note on dynamic predictors. Arch Surg 123:727-732.
    • (1989) Arch Surg , vol.123 , pp. 727-732
    • Pillari, G.1    Chang, J.B.2    Zito, J.3
  • 6
    • 0025681304 scopus 로고
    • Conventional CT of the aorta
    • 6. Godwin JD (1990) Conventional CT of the aorta. J Thorac Imaging 5:18-31.
    • (1990) J Thorac Imaging , vol.5 , pp. 18-31
    • Godwin, J.D.1
  • 8
    • 0026544192 scopus 로고
    • Diagnosis of thoracic aortic dissection: Magnetic resonance imaging versus transesophageal echocardiography
    • 8. Nienaber CA, Spielmann RP, von Kodolitsch Y, et al (1992) Diagnosis of thoracic aortic dissection: Magnetic resonance imaging versus transesophageal echocardiography. Circulation 85:434-447.
    • (1992) Circulation , vol.85 , pp. 434-447
    • Nienaber, C.A.1    Spielmann, R.P.2    Von, K.Y.3
  • 9
    • 0026485381 scopus 로고
    • Hypointense boundary layer between slow flow and mural thrombus on spin-echo MR
    • 9. Chung JW, Park JH, Han JK, et al (1992) Hypointense boundary layer between slow flow and mural thrombus on spin-echo MR. J Comput Assist Tomogr 16:944-950.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 944-950
    • Chung, J.W.1    Park, J.H.2    Han, J.K.3
  • 10
    • 0027397484 scopus 로고
    • The diagnosis of thoracic aortic dissection by noninvasive imaging procedures
    • 10. Nienaber CA, Kodolitsch YV, Nicolas V, et al (1993) The diagnosis of thoracic aortic dissection by noninvasive imaging procedures. N Engl J Med 328:1-9.
    • (1993) N Engl J Med , vol.328 , pp. 1-9
    • Nienaber, C.A.1    Kodolitsch, Y.V.2    Nicolas, V.3
  • 11
    • 0017566176 scopus 로고
    • Assessment of abdominal aortic aneurysm size
    • 11. Brewster DC, Darling RC, Raines JK, et al (1977) Assessment of abdominal aortic aneurysm size. Circulation 56 (suppl 2):11164-11169.
    • (1977) Circulation , vol.56 , Issue.SUPPL. 2 , pp. 11164-11169
    • Brewster, D.C.1    Darling, R.C.2    Raines, J.K.3
  • 12
    • 0019274057 scopus 로고
    • Ultrasonic and computed tomographic imaging of the abdominal aorta
    • 12. Hattery RR, Williamson B, Wallace RB (1980) Ultrasonic and computed tomographic imaging of the abdominal aorta. World J Surg 4:511-519.
    • (1980) World J Surg , vol.4 , pp. 511-519
    • Hattery, R.R.1    Williamson, B.2    Wallace, R.B.3
  • 13
    • 0024509769 scopus 로고
    • Quantification of blood flow with dynamic MR imaging and presaturation bolus tracking
    • 13. Edelman RR, Mattle HP, Kleefield J, et al (1989) Quantification of blood flow with dynamic MR imaging and presaturation bolus tracking. Radiology 171:551-556.
    • (1989) Radiology , vol.171 , pp. 551-556
    • Edelman, R.R.1    Mattle, H.P.2    Kleefield, J.3
  • 14
    • 0013520473 scopus 로고
    • Application of cine MRI-tagging method to aortic dissection
    • 14. Yoshioka K, Takahashi T, Kamata H, et al (1992) Application of cine MRI-tagging method to aortic dissection. Jpn J Magn Reson Med 12:301-305 (in Japanese with English summary).
    • (1992) Jpn J Magn Reson Med , vol.12 , pp. 301-305
    • Yoshioka, K.1    Takahashi, T.2    Kamata, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.