메뉴 건너뛰기




Volumn 70, Issue 1, 1999, Pages 58-61

Bioelectric impedance as an index of thoracic fluid

Author keywords

Central blood volume; Gender; Impedance plethysmography; Posture

Indexed keywords

ADULT; ARTICLE; BLOOD PRESSURE; BODY FLUID; BODY POSTURE; CONTROLLED STUDY; FEMALE; HEART RATE; HEART STROKE VOLUME; HUMAN; HUMAN EXPERIMENT; IMPEDANCE PLETHYSMOGRAPHY; LUNG BLOOD VOLUME; LUNG CAPILLARY; LUNG DIFFUSION CAPACITY; MALE; NORMAL HUMAN; THORAX;

EID: 0032924406     PISSN: 00956562     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (27)
  • 1
    • 0023442646 scopus 로고
    • Standardization of spirometry-1987 update
    • American Thoracic Society. Standardization of spirometry-1987 update. Am Rev Respir Dis 1987; 136:1285-98.
    • (1987) Am Rev Respir Dis , vol.136 , pp. 1285-1298
  • 2
    • 0016900425 scopus 로고
    • Changes in transthoracic electrical impedance during submaximal treadmill exercise in patients with ischemic heart disease - A preliminary report
    • Balasubramanian V, Hoon RS. Changes in transthoracic electrical impedance during submaximal treadmill exercise in patients with ischemic heart disease - a preliminary report. Am Heart J 1976; 91:43-9.
    • (1976) Am Heart J , vol.91 , pp. 43-49
    • Balasubramanian, V.1    Hoon, R.S.2
  • 3
    • 0038804893 scopus 로고
    • Variations in the pulmonary capillary blood volume and membrane diffusion component in health and disease
    • Bates DV, Varvis CJ, Donevan RE, Christie RV. Variations in the pulmonary capillary blood volume and membrane diffusion component in health and disease. J Clin Invest 1960; 39:1401-12.
    • (1960) J Clin Invest , vol.39 , pp. 1401-1412
    • Bates, D.V.1    Varvis, C.J.2    Donevan, R.E.3    Christie, R.V.4
  • 4
    • 0014984332 scopus 로고
    • Transthoracic electrical impedance as a guide to intravascular overload
    • Berman IR, Scheetz LTC, Jenkins EB, Hufnagel HV. Transthoracic electrical impedance as a guide to intravascular overload. Archiv Surg 1971; 102:61-4.
    • (1971) Archiv Surg , vol.102 , pp. 61-64
    • Berman, I.R.1    Scheetz, L.T.C.2    Jenkins, E.B.3    Hufnagel, H.V.4
  • 5
    • 0023010820 scopus 로고
    • Effects of furosemide and slow-release furosemide on thoracic fluid volumes
    • Brodin LA, Jogestrand T, Larsen FF, et al. Effects of furosemide and slow-release furosemide on thoracic fluid volumes. Clin Cardiol 1986; 9:561-4.
    • (1986) Clin Cardiol , vol.9 , pp. 561-564
    • Brodin, L.A.1    Jogestrand, T.2    Larsen, F.F.3
  • 6
    • 0028308085 scopus 로고
    • Clinical applications of electrical impedance tomography in the monitoring of changes in intrathoracic fluid volumes
    • Campbell JH, Harris ND, Zhang F, et al. Clinical applications of electrical impedance tomography in the monitoring of changes in intrathoracic fluid volumes. Physiol Measur 1994; 15:A217-A222.
    • (1994) Physiol Measur , vol.15
    • Campbell, J.H.1    Harris, N.D.2    Zhang, F.3
  • 7
    • 0016812551 scopus 로고
    • Measurement of pleural effusion by electrical impedance
    • Denniston JC, Baker LE. Measurement of pleural effusion by electrical impedance. J Appl Physiol 1975; 38:851-7.
    • (1975) J Appl Physiol , vol.38 , pp. 851-857
    • Denniston, J.C.1    Baker, L.E.2
  • 8
    • 0022653845 scopus 로고
    • The use of thoracic impedance for determining thoracic blood volume changes in man
    • Ebert TJ, Smith JJ, Barney JA, et al. The use of thoracic impedance for determining thoracic blood volume changes in man. Aviat Space Environ Med 1986; 57:49-53.
    • (1986) Aviat Space Environ Med , vol.57 , pp. 49-53
    • Ebert, T.J.1    Smith, J.J.2    Barney, J.A.3
  • 9
    • 0020364164 scopus 로고
    • Transthoracic impedance: Differences between men and women with implications for impedance cardiography
    • Frey MAB, Doerr B, Miles DS. Transthoracic impedance: differences between men and women with implications for impedance cardiography. Aviat Space Environ Med 1982; 53:1190-2.
    • (1982) Aviat Space Environ Med , vol.53 , pp. 1190-1192
    • Frey, M.A.B.1    Doerr, B.2    Miles, D.S.3
  • 10
    • 0028347617 scopus 로고
    • Comparison of band and spot electrodes for the measurement of stroke volume by the bioelectric impedance technique
    • Gotshall RW, Sexson WR. Comparison of band and spot electrodes for the measurement of stroke volume by the bioelectric impedance technique. Crit Care Med 1994; 22:420-5.
    • (1994) Crit Care Med , vol.22 , pp. 420-425
    • Gotshall, R.W.1    Sexson, W.R.2
  • 11
    • 0028048977 scopus 로고
    • Validation study of thoracic fluid bioimpedance for assessing the haemodialysis-induced changes in total body fluids
    • Graziani G, Badalamenti S, Como G, et al. Validation study of thoracic fluid bioimpedance for assessing the haemodialysis-induced changes in total body fluids. Blood Purif 1994; 12:106-12.
    • (1994) Blood Purif , vol.12 , pp. 106-112
    • Graziani, G.1    Badalamenti, S.2    Como, G.3
  • 12
    • 0028970269 scopus 로고
    • Thoracic electrical impedance and fluid balance during aortic surgery
    • Jonsson F, Madsen P, Jorgensen LG, et al. Thoracic electrical impedance and fluid balance during aortic surgery. Acta Anaesthiol Scand 1995; 39:513-7.
    • (1995) Acta Anaesthiol Scand , vol.39 , pp. 513-517
    • Jonsson, F.1    Madsen, P.2    Jorgensen, L.G.3
  • 13
    • 0017557087 scopus 로고
    • Quantitative electrical-impedance plethysmography for pulmonary edema
    • Khan MR, Tandon S. Quantitative electrical-impedance plethysmography for pulmonary edema. Med Biol Eng Comput 1977; 15:627-33.
    • (1977) Med Biol Eng Comput , vol.15 , pp. 627-633
    • Khan, M.R.1    Tandon, S.2
  • 14
    • 0021810985 scopus 로고
    • An impedance cardiographic study of the mechanism of blood pressure fall after moderate dietary sodium restriction
    • Koga Y, Gillum RF, Kubicek WG. An impedance cardiographic study of the mechanism of blood pressure fall after moderate dietary sodium restriction. Jap Heart J 1985; 26:197-207.
    • (1985) Jap Heart J , vol.26 , pp. 197-207
    • Koga, Y.1    Gillum, R.F.2    Kubicek, W.G.3
  • 15
    • 0013978742 scopus 로고
    • Development and evaluation of an impedance cardiac output system
    • Kubicek WG, Karnegis JN, Patterson RP, et al. Development and evaluation of an impedance cardiac output system. Aerosp Med 1966; 37:1208-12.
    • (1966) Aerosp Med , vol.37 , pp. 1208-1212
    • Kubicek, W.G.1    Karnegis, J.N.2    Patterson, R.P.3
  • 16
    • 0016100772 scopus 로고
    • The Minnesota impedance cardiograph-theory and applications
    • Kubicek WG, Kotte FJ, Ramos MU, et al. The Minnesota impedance cardiograph-theory and applications. Biomed Eng 1974; 9:410-6.
    • (1974) Biomed Eng , vol.9 , pp. 410-416
    • Kubicek, W.G.1    Kotte, F.J.2    Ramos, M.U.3
  • 17
    • 0023029928 scopus 로고
    • Influence of furosemide and body posture on transthoracic electrical impedance in AMI
    • Larsen F, Mogensen L, Tedner B. Influence of furosemide and body posture on transthoracic electrical impedance in AMI. Chest 1986; 90:733-7.
    • (1986) Chest , vol.90 , pp. 733-737
    • Larsen, F.1    Mogensen, L.2    Tedner, B.3
  • 18
    • 0023152279 scopus 로고
    • Transthoracic electrical impedance at 1 and 100 kHz - A means for separating thoracic fluid compartments?
    • Larsen FF, Mogensen L, Tedner B. Transthoracic electrical impedance at 1 and 100 kHz - a means for separating thoracic fluid compartments? Clin Physiol 1987; 7:105-13.
    • (1987) Clin Physiol , vol.7 , pp. 105-113
    • Larsen, F.F.1    Mogensen, L.2    Tedner, B.3
  • 19
    • 0015540539 scopus 로고
    • Transthoracic electrical impedance: Quantitative evaluation of a non-invasive measure of thoracic fluid volume
    • Luepker RV, Michael JR, Warbasse JR. Transthoracic electrical impedance: quantitative evaluation of a non-invasive measure of thoracic fluid volume. Am Heart J 1973; 85:83-93.
    • (1973) Am Heart J , vol.85 , pp. 83-93
    • Luepker, R.V.1    Michael, J.R.2    Warbasse, J.R.3
  • 20
    • 0020582222 scopus 로고
    • Changes in pulmonary diffusing capacity and closing volume after running a marathon
    • Miles DS, Doerr CE, Schonfeld SA, et al. Changes in pulmonary diffusing capacity and closing volume after running a marathon. Respir Physiol 1983; 52:349-59.
    • (1983) Respir Physiol , vol.52 , pp. 349-359
    • Miles, D.S.1    Doerr, C.E.2    Schonfeld, S.A.3
  • 21
    • 84965092916 scopus 로고
    • A standardized breath holding technique for the clinical measurement of the diffusing capacity of the lung for carbon monoxide
    • Ogilivie CM, Forster RE, Blakemore WS, Morton JW. A standardized breath holding technique for the clinical measurement of the diffusing capacity of the lung for carbon monoxide. J Clin Invest 1957; 36:1-17.
    • (1957) J Clin Invest , vol.36 , pp. 1-17
    • Ogilivie, C.M.1    Forster, R.E.2    Blakemore, W.S.3    Morton, J.W.4
  • 22
    • 0014902716 scopus 로고
    • Transthoracic impedance, with special reference to newborn infants and the ratio air-to-fluid in the lungs
    • Olsson VL. Transthoracic impedance, with special reference to newborn infants and the ratio air-to-fluid in the lungs. Acta Paediat Scand 1970(Suppl); 207:1-5.
    • (1970) Acta Paediat Scand , vol.207 , Issue.SUPPL. , pp. 1-5
    • Olsson, V.L.1
  • 23
    • 0014549410 scopus 로고
    • Transthoracic electrical impedance for the early detection of pulmonary edema
    • Pomerantz M, Baumgartner R, Lauridson J, Eiseman B. Transthoracic electrical impedance for the early detection of pulmonary edema. Surgery 1969; 66:260-8.
    • (1969) Surgery , vol.66 , pp. 260-268
    • Pomerantz, M.1    Baumgartner, R.2    Lauridson, J.3    Eiseman, B.4
  • 24
    • 0016752422 scopus 로고
    • Transthoracic electric impedance: A clinical guide of pulmonary fluid accumulation in congestive heart failure
    • Ramos MU, Labree JW, Remole W, Kubiceck WG. Transthoracic electric impedance: a clinical guide of pulmonary fluid accumulation in congestive heart failure. Minnesota Med 1975; 58:671-6.
    • (1975) Minnesota Med , vol.58 , pp. 671-676
    • Ramos, M.U.1    Labree, J.W.2    Remole, W.3    Kubiceck, W.G.4
  • 25
    • 70449193465 scopus 로고
    • Relative importance of diffusion and chemical reaction rates in determining rate of exchange of gases in the human lung, with special reference to the true diffusion capacity of pulmonary membrane and volume of blood in the lung capillaries
    • Roughton FJ, Forster RE. Relative importance of diffusion and chemical reaction rates in determining rate of exchange of gases in the human lung, with special reference to the true diffusion capacity of pulmonary membrane and volume of blood in the lung capillaries. J Appl Physiol 1957; 11:290-302.
    • (1957) J Appl Physiol , vol.11 , pp. 290-302
    • Roughton, F.J.1    Forster, R.E.2
  • 26
    • 0026009707 scopus 로고
    • Cardiothoracic parameters measured by bioelectric impedance in preterm and term neonates
    • Sexson WR, Gotshall RW, Miles DS. Cardiothoracic parameters measured by bioelectric impedance in preterm and term neonates. Crit Care Med 1991; 19:1054-9.
    • (1991) Crit Care Med , vol.19 , pp. 1054-1059
    • Sexson, W.R.1    Gotshall, R.W.2    Miles, D.S.3
  • 27
    • 0015072312 scopus 로고
    • Bioelectric impedance: New developments and clinical application
    • Van De Water JM, Phillips PA, Thouin LG, et al. Bioelectric impedance: new developments and clinical application. Archiv Surg 1971; 102:541-7.
    • (1971) Archiv Surg , vol.102 , pp. 541-547
    • Van De Water, J.M.1    Phillips, P.A.2    Thouin, L.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.