메뉴 건너뛰기




Volumn 22, Issue 2, 1999, Pages 103-108

Elastic deformation properties of implanted endobronchial wire stents in benign and malignant bronchial disease: A radiographic in vivo evaluation

Author keywords

Airway stents; Bronchial diseases, therapy; Elasticity; Fluoroscopy; Prosthesis design

Indexed keywords

ARTICLE; BRONCHOSCOPY; BRONCHUS DISEASE; BRONCHUS STENOSIS; CLINICAL ARTICLE; ELASTICITY; FLUOROSCOPY; HUMAN; PRIORITY JOURNAL; PROSTHESIS; PROSTHESIS FAILURE; PROSTHESIS FIXATION; RADIOLOGY; RESPIRATORY FUNCTION; STENT;

EID: 0032921868     PISSN: 01741551     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002709900343     Document Type: Article
Times cited : (11)

References (17)
  • 1
    • 0023278960 scopus 로고
    • The use of bronchial stents in the management of bronchomalacia
    • Goddard JM, Booker PD (1987) The use of bronchial stents in the management of bronchomalacia. Anaesthesia 42:534-535
    • (1987) Anaesthesia , vol.42 , pp. 534-535
    • Goddard, J.M.1    Booker, P.D.2
  • 2
    • 0025072582 scopus 로고
    • Treatment of severe bronchomalacia with expanding endobronchial stents
    • Mair EA, Parsons DS, Lally KP (1990) Treatment of severe bronchomalacia with expanding endobronchial stents. Arch Otolaryngol Head Neck Surg 116:1087-1090
    • (1990) Arch Otolaryngol Head Neck Surg , vol.116 , pp. 1087-1090
    • Mair, E.A.1    Parsons, D.S.2    Lally, K.P.3
  • 3
    • 0026279804 scopus 로고
    • Tracheobronchial stents: Indications and possibilities
    • in German
    • Breyer G, Haussinger K (1991) Tracheobronchial stents: Indications and possibilities. Pneumologie 45:997-1003 (in German)
    • (1991) Pneumologie , vol.45 , pp. 997-1003
    • Breyer, G.1    Haussinger, K.2
  • 4
    • 0029883830 scopus 로고    scopus 로고
    • Treatment of large airway obstruction in lung cancer using expandable metal stents inserted under direct vision via the fiberoptic bronchoscope
    • Wilson GE, Walshaw MJ, Hind CRK (1996) Treatment of large airway obstruction in lung cancer using expandable metal stents inserted under direct vision via the fiberoptic bronchoscope. Thorax 51:248-252
    • (1996) Thorax , vol.51 , pp. 248-252
    • Wilson, G.E.1    Walshaw, M.J.2    Hind, C.R.K.3
  • 6
    • 0029849458 scopus 로고    scopus 로고
    • An airway Wallstent for the treatment of tracheobronchial malignancies
    • Bolliger CT, Heitz M, Hauser R, Probst R, Perruchoud AP (1996) An airway Wallstent for the treatment of tracheobronchial malignancies. Thorax 51:1127-1129
    • (1996) Thorax , vol.51 , pp. 1127-1129
    • Bolliger, C.T.1    Heitz, M.2    Hauser, R.3    Probst, R.4    Perruchoud, A.P.5
  • 7
    • 0030861716 scopus 로고    scopus 로고
    • Tracheal stenosis treated with self-expanding nitinol stent
    • Yanagihara K, Mizuno H, Wada H, Hitomi S (1997) Tracheal stenosis treated with self-expanding nitinol stent. Ann Thorac Surg 63:1786-1789
    • (1997) Ann Thorac Surg , vol.63 , pp. 1786-1789
    • Yanagihara, K.1    Mizuno, H.2    Wada, H.3    Hitomi, S.4
  • 9
    • 0025986286 scopus 로고
    • Bronchial endoprostheses (stents) in inoperable bronchial carcinoma
    • in German
    • Hurter T, Bohndorf K, Kropff M, Günther RW, Hanrath P (1991) Bronchial endoprostheses (stents) in inoperable bronchial carcinoma. Pneumologie 45:19-22 (in German)
    • (1991) Pneumologie , vol.45 , pp. 19-22
    • Hurter, T.1    Bohndorf, K.2    Kropff, M.3    Günther, R.W.4    Hanrath, P.5
  • 10
    • 0029932161 scopus 로고    scopus 로고
    • Stent flexibility: An essential feature in the treatment of dynamic airway collapse
    • Hautmann H, Huber RM (1996) Stent flexibility: An essential feature in the treatment of dynamic airway collapse. Eur Respir J 9:609-611
    • (1996) Eur Respir J , vol.9 , pp. 609-611
    • Hautmann, H.1    Huber, R.M.2
  • 11
    • 0026479024 scopus 로고
    • Expanding wire stents in benign tracheobronchial disease: Indications and complications
    • Nashef SA, Dromer C, Velly JF, Labrousse L, Couraud L (1992) Expanding wire stents in benign tracheobronchial disease: Indications and complications. Ann Thorac Surg 54:937-940
    • (1992) Ann Thorac Surg , vol.54 , pp. 937-940
    • Nashef, S.A.1    Dromer, C.2    Velly, J.F.3    Labrousse, L.4    Couraud, L.5
  • 12
    • 0031036718 scopus 로고    scopus 로고
    • Tracheal wire stent complications in malacia: Implications of position and design
    • Hramiec JE, Haasler GB (1997) Tracheal wire stent complications in malacia: Implications of position and design. Ann Thorac Surg 63:209-213
    • (1997) Ann Thorac Surg , vol.63 , pp. 209-213
    • Hramiec, J.E.1    Haasler, G.B.2
  • 13
    • 0028394295 scopus 로고
    • Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis
    • Lossef SV, Lutz RJ, Mundorf J, Barth KH (1994) Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis. J Vasc Interv Radiol 5:341-349
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 341-349
    • Lossef, S.V.1    Lutz, R.J.2    Mundorf, J.3    Barth, K.H.4
  • 16
    • 0000945606 scopus 로고
    • Physical dynamics of the cough mechanism
    • Ross BB, Gramiak R, Rahn H (1955) Physical dynamics of the cough mechanism. J Appl Physiol 8:264-268
    • (1955) J Appl Physiol , vol.8 , pp. 264-268
    • Ross, B.B.1    Gramiak, R.2    Rahn, H.3
  • 17
    • 0028032088 scopus 로고
    • Balloon dilatation and self-expanding metal Wallstent insertion for management of bronchostenosis following lung transplantation
    • The Toulouse Lung Transplantation Group
    • Carre P, Rousseau H, Lombart L, Didier A, Dahan M, Fournial G, Leophonte P (1994) Balloon dilatation and self-expanding metal Wallstent insertion for management of bronchostenosis following lung transplantation. The Toulouse Lung Transplantation Group. Chest 105: 343-348
    • (1994) Chest , vol.105 , pp. 343-348
    • Carre, P.1    Rousseau, H.2    Lombart, L.3    Didier, A.4    Dahan, M.5    Fournial, G.6    Leophonte, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.