메뉴 건너뛰기




Volumn 25, Issue 4, 1999, Pages 577-582

Time-averaged mean velocity for volumetric blood flow measurements: An in vitro model validation study using physiological femoral artery flow waveforms

Author keywords

Beam profile; Doppler; Flow model; Peripheral vascular disease; Volumetric flow measurements

Indexed keywords

BLOOD; BLOOD VESSELS; CARDIOVASCULAR SYSTEM; FLOW MEASUREMENT; MATHEMATICAL MODELS; MEASUREMENT ERRORS; MICROCIRCULATION; PHYSIOLOGY; VELOCITY MEASUREMENT; WAVEFORM ANALYSIS;

EID: 0032914768     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(99)00010-1     Document Type: Article
Times cited : (4)

References (15)
  • 1
    • 0014797429 scopus 로고
    • Pulsed ultrasonic Doppler blood-flow sensing
    • Baker D.W. Pulsed ultrasonic Doppler blood-flow sensing. IEEE Trans Sonics Ultrasonics. SU-17:1970;170-185.
    • (1970) IEEE Trans Sonics Ultrasonics , vol.17 , pp. 170-185
    • Baker, D.W.1
  • 2
    • 85047676883 scopus 로고
    • Pulsed Doppler ultrasound compared with thermodilution for monitoring cardiac output responses to changing left ventricular volume
    • Bojanowski L.M.R., Timmis A.D., Najm Y.C., et al. Pulsed Doppler ultrasound compared with thermodilution for monitoring cardiac output responses to changing left ventricular volume. Cardiovasc Res. 21:1987;260-268.
    • (1987) Cardiovasc Res , vol.21 , pp. 260-268
    • Bojanowski, L.M.R.1    Timmis, A.D.2    Najm, Y.C.3
  • 3
    • 0020844585 scopus 로고
    • Influence of the beam profile and degree of insonation on the CW Doppler ultrasound spectrum and mean velocity
    • Cobbold R.S.C., Veltink P.H., Johnston K.W. Influence of the beam profile and degree of insonation on the CW Doppler ultrasound spectrum and mean velocity. IEEE Trans Sonics Ultrasonics. SU-30:1983;364-370.
    • (1983) IEEE Trans Sonics Ultrasonics , vol.30 , pp. 364-370
    • Cobbold, R.S.C.1    Veltink, P.H.2    Johnston, K.W.3
  • 4
    • 0020393442 scopus 로고
    • Some aspects of the relationship between instantaneous volumetric blood flow and continuous wave Doppler ultrasound recordings - I. The effect of ultrasonic beam width on the output of maximum, mean and RMS frequency processors
    • Evans D.H. Some aspects of the relationship between instantaneous volumetric blood flow and continuous wave Doppler ultrasound recordings - I. The effect of ultrasonic beam width on the output of maximum, mean and RMS frequency processors. Ultrasound Med Biol. 8:1982;605-609.
    • (1982) Ultrasound Med Biol , vol.8 , pp. 605-609
    • Evans, D.H.1
  • 5
    • 0022391705 scopus 로고
    • On the measurement of the mean velocity of blood flow over the cardiac cycle using Doppler ultrasound
    • Evans D.H. On the measurement of the mean velocity of blood flow over the cardiac cycle using Doppler ultrasound. Ultrasound Med Biol. 11:1985;735-741.
    • (1985) Ultrasound Med Biol , vol.11 , pp. 735-741
    • Evans, D.H.1
  • 6
    • 0022260296 scopus 로고
    • Measurement of blood flow by ultrasound: Accuracy and sources of error
    • Gill R.W. Measurement of blood flow by ultrasound Accuracy and sources of error . Ultrasound Med Biol. 11:1985;625-641.
    • (1985) Ultrasound Med Biol , vol.11 , pp. 625-641
    • Gill, R.W.1
  • 7
    • 0020672803 scopus 로고
    • Noninvasive Doppler determination of cardiac output in man. Clinical validation
    • Huntsman L.L., Stewart D.K., Barnes S.R., et al. Noninvasive Doppler determination of cardiac output in man. Clinical validation. Circulation. 67:1983;593-602.
    • (1983) Circulation , vol.67 , pp. 593-602
    • Huntsman, L.L.1    Stewart, D.K.2    Barnes, S.R.3
  • 8
    • 0029885208 scopus 로고    scopus 로고
    • Blood flow in the lower limb after balloon angioplasty of the superficial femoral artery
    • Hussain S.T., Smith R.E., Clark A.L., et al. Blood flow in the lower limb after balloon angioplasty of the superficial femoral artery. Br J Surg. 83:1996;791-795.
    • (1996) Br J Surg , vol.83 , pp. 791-795
    • Hussain, S.T.1    Smith, R.E.2    Clark, A.L.3
  • 9
    • 0029970225 scopus 로고    scopus 로고
    • Observer variability in volumetric blood flow measurements in leg arteries using duplex ultrasound
    • Hussain S.T., Smith R.E., Wood R.F.M., et al. Observer variability in volumetric blood flow measurements in leg arteries using duplex ultrasound. Ultrasound Med Biol. 22:1996;287-291.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 287-291
    • Hussain, S.T.1    Smith, R.E.2    Wood, R.F.M.3
  • 10
    • 0022800805 scopus 로고
    • Measurement of volume flow in the human common femoral artery using a duplex ultrasound system
    • Lewis P., Psaila J.V., Davis W.T., et al. Measurement of volume flow in the human common femoral artery using a duplex ultrasound system. Ultrasound Med Biol. 12:1986;777-784.
    • (1986) Ultrasound Med Biol , vol.12 , pp. 777-784
    • Lewis, P.1    Psaila, J.V.2    Davis, W.T.3
  • 11
    • 0025159167 scopus 로고
    • Common femoral artery volume flow in peripheral vascular disease
    • Lewis P., Psaila J.V., Morgan R.H., et al. Common femoral artery volume flow in peripheral vascular disease. Br J Surg. 77:1990;183-187.
    • (1990) Br J Surg , vol.77 , pp. 183-187
    • Lewis, P.1    Psaila, J.V.2    Morgan, R.H.3
  • 12
    • 0020535446 scopus 로고
    • Femoral blood flow determination with a multichannel digital pulsed Doppler: An experimental study on anesthetized dogs
    • Marquis C., Meister J.J., Mirkovitch V., et al. Femoral blood flow determination with a multichannel digital pulsed Doppler An experimental study on anesthetized dogs . Vasc Surg. 17:1983;95-103.
    • (1983) Vasc Surg , vol.17 , pp. 95-103
    • Marquis, C.1    Meister, J.J.2    Mirkovitch, V.3
  • 13
    • 0025998392 scopus 로고
    • Towards an ideal blood analogue for Doppler ultrasound phantoms
    • Oates C.P. Towards an ideal blood analogue for Doppler ultrasound phantoms. Phys Med Biol. 36:1991;1433-1442.
    • (1991) Phys Med Biol , vol.36 , pp. 1433-1442
    • Oates, C.P.1
  • 14
    • 0022003491 scopus 로고
    • Flow velocity patterns in and distensibility of the carotid artery bulb in subjects of various ages
    • Reneman R.S., van Merode T., Hick P., et al. Flow velocity patterns in and distensibility of the carotid artery bulb in subjects of various ages. Circulation. 77:1985;500-509.
    • (1985) Circulation , vol.77 , pp. 500-509
    • Reneman, R.S.1    Van Merode, T.2    Hick, P.3
  • 15
    • 0021044956 scopus 로고
    • Limitations of early Doppler spectral broadening in the early detection of carotid artery disease due to the size of the sample volume
    • van Merode T., Hick P., Hoeks A.P.G., et al. Limitations of early Doppler spectral broadening in the early detection of carotid artery disease due to the size of the sample volume. Ultrasound Med Biol. 9:1983;581-586.
    • (1983) Ultrasound Med Biol , vol.9 , pp. 581-586
    • Van Merode, T.1    Hick, P.2    Hoeks, A.P.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.