메뉴 건너뛰기




Volumn 19, Issue 3, 1999, Pages 148-152

Assessment of tissue blood flow following small artery welding with an intraluminal dissolvable stent

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ARTERY ANASTOMOSIS; ARTERY BLOOD FLOW; ARTICLE; BLOOD FLOW VELOCITY; CARBON DIOXIDE LASER; FEMORAL ARTERY; LASER SURGERY; NONHUMAN; PRIORITY JOURNAL; RAT; SUTURING METHOD;

EID: 0032914558     PISSN: 07381085     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1098-2752(1999)19:3<148::AID-MICR5>3.0.CO;2-M     Document Type: Article
Times cited : (13)

References (18)
  • 1
    • 0000222491 scopus 로고
    • Microsurgery in anastomosis of small vessels
    • Jacobson JH, Suarez EL. Microsurgery in anastomosis of small vessels. Surg Forum 1960;11:243-245.
    • (1960) Surg Forum , vol.11 , pp. 243-245
    • Jacobson, J.H.1    Suarez, E.L.2
  • 2
    • 0030431402 scopus 로고    scopus 로고
    • Heat-induced tissue fusion for microvascular anastomosis
    • Cooley BC. Heat-induced tissue fusion for microvascular anastomosis. Microsurgery 1996;17:198-208.
    • (1996) Microsurgery , vol.17 , pp. 198-208
    • Cooley, B.C.1
  • 3
    • 0029148928 scopus 로고
    • Effect of isovolemic hemodilution with dextran and albumin on thrombus formation in artificial vessel grafts inserted into the abdominal aorta of the rabbit
    • Frost-Arner L, Bergqvist D. Effect of isovolemic hemodilution with dextran and albumin on thrombus formation in artificial vessel grafts inserted into the abdominal aorta of the rabbit. Microsurgery 1995;16: 357-361.
    • (1995) Microsurgery , vol.16 , pp. 357-361
    • Frost-Arner, L.1    Bergqvist, D.2
  • 4
    • 0025859080 scopus 로고
    • Experimental study on microvascular anastomosis using a dissolvable stent support in the lumen
    • Zhang C, Tang NX, Zheng CF, Xu YW, Wang TD. Experimental study on microvascular anastomosis using a dissolvable stent support in the lumen. Microsurgery 1991;12:67-71.
    • (1991) Microsurgery , vol.12 , pp. 67-71
    • Zhang, C.1    Tang, N.X.2    Zheng, C.F.3    Xu, Y.W.4    Wang, T.D.5
  • 7
    • 0029094126 scopus 로고
    • Can varying flow velocity across an arterial anastomosis prevent thromboembolic injury?
    • Barker JH, Andresen DM, Anderson GL, et al. Can varying flow velocity across an arterial anastomosis prevent thromboembolic injury? Microsurgery 1995;16:349-356.
    • (1995) Microsurgery , vol.16 , pp. 349-356
    • Barker, J.H.1    Andresen, D.M.2    Anderson, G.L.3
  • 8
    • 0030939914 scopus 로고    scopus 로고
    • Venous micro anastomosis with the UNILINK system, sleeve, and suture techniques: A comparative study in the rat
    • Zhang L, Kolker AR, Choe EI, et al. Venous micro anastomosis with the UNILINK system, sleeve, and suture techniques: a comparative study in the rat. J Reconstr Microsurg 1997;13:257-261.
    • (1997) J Reconstr Microsurg , vol.13 , pp. 257-261
    • Zhang, L.1    Kolker, A.R.2    Choe, E.I.3
  • 9
    • 0025203955 scopus 로고
    • Microvascular grafts: Effect of diameter discrepancy on patency rates
    • Monsivais JJ. Microvascular grafts: effect of diameter discrepancy on patency rates. Microsurgery 1990;11:285-287.
    • (1990) Microsurgery , vol.11 , pp. 285-287
    • Monsivais, J.J.1
  • 10
    • 0018635722 scopus 로고
    • Repair of small blood vessels with the neodynium-YAG laser: A preliminary report
    • Jain KK, Gorisch W. Repair of small blood vessels with the neodynium-YAG laser: a preliminary report. Surgery 1979;85:684-688.
    • (1979) Surgery , vol.85 , pp. 684-688
    • Jain, K.K.1    Gorisch, W.2
  • 11
    • 0023974799 scopus 로고
    • 2 laser-assisted microvascular anastomosis: An experimental study
    • 2 laser-assisted microvascular anastomosis: an experimental study. Neurosurgery 1988;22:540-543.
    • (1988) Neurosurgery , vol.22 , pp. 540-543
    • Guo, J.1    Chao, Y.D.2
  • 12
    • 0344485883 scopus 로고
    • Stent assisted laser welding in a rabbit model
    • He FC, Tang NX. Stent assisted laser welding in a rabbit model. Med J PLA 1994;19:383-385.
    • (1994) Med J PLA , vol.19 , pp. 383-385
    • He, F.C.1    Tang, N.X.2
  • 13
    • 0014114779 scopus 로고
    • The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow
    • Rudolph AM, Heymann MA. The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow. Cir Res 1967;21:163-184.
    • (1967) Cir Res , vol.21 , pp. 163-184
    • Rudolph, A.M.1    Heymann, M.A.2
  • 16
    • 0029127856 scopus 로고
    • Sympathetic blockade of isolated rat hindlimbs by intra-arterial guanethidine: The effect on blood flow and arterial-venous shunting
    • McCarty ME, Grossi EA, Cutting C, Prevel CD, Elluru R, Epplley B. Sympathetic blockade of isolated rat hindlimbs by intra-arterial guanethidine: the effect on blood flow and arterial-venous shunting. Microsurgery 1995;16:476-481.
    • (1995) Microsurgery , vol.16 , pp. 476-481
    • McCarty, M.E.1    Grossi, E.A.2    Cutting, C.3    Prevel, C.D.4    Elluru, R.5    Epplley, B.6
  • 17
    • 0345348270 scopus 로고
    • Xi'an: Science and Technology Publishing House
    • Shi XY, editor. Laboratory animal science. 1st ed. Xi'an: Science and Technology Publishing House; 1989. p 471-481.
    • (1989) Laboratory Animal Science. 1st Ed. , pp. 471-481
    • Shi, X.Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.