Volumn 26, Issue 2, 1999, Pages 276-286

Reduced partial volume artifacts using spiral computed tomography and an integrating interpolator

Author keywords

And low contrast resolution; Partial volume reduction; Slice sensitivity profile (SSP); Spiral CT of the head; Spiral interpolation

Indexed keywords

INTERPOLATION; POSITRON EMISSION TOMOGRAPHY;

EID: 0032914530     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598523     Document Type: Article
Times cited : (17)

References (15)
  • 1
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breathhold technique, continuous transport and continuous scanner rotation
    • W. A. Kalender, W. Seissler, E. Klotz, and P. Vock, "Spiral volumetric CT with single-breathhold technique, continuous transport and continuous scanner rotation," Radiology 176, 181-183 (1990).
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 2
    • 0026048199 scopus 로고
    • Physical performance characteristics of spiral CT scanning
    • W. A. Kalender and A. Polacin, "Physical performance characteristics of spiral CT scanning," Med. Phys. 18, 910-915 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 910-915
    • Kalender, W.A.1    Polacin, A.2
  • 3
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C. R. Crawford and K. F. King, "Computed tomography scanning with simultaneous patient translation," Med. Phys. 17, 967-982 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 4
    • 0025369888 scopus 로고
    • Spiral scanning and the influence of reconstruction algorithm on image quality
    • H. Rigauts, G. Marchal, A. L. Baert, and R. Hupke, "Spiral scanning and the influence of reconstruction algorithm on image quality," J. Comput. Assist. Tomogr. 14, 675-682 (1990).
    • (1990) J. Comput. Assist. Tomogr. , vol.14 , pp. 675-682
    • Rigauts, H.1    Marchal, G.2    Baert, A.L.3    Hupke, R.4
  • 5
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • A. Polacin, W. A. Kalender, and G. Marchal, "Evaluation of section sensitivity profiles and image noise in spiral CT," Radiology 185, 29-35 (1992).
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 6
    • 0003745581 scopus 로고
    • Evaluation of spiral CT on a fourth generation system
    • M. D. Reynolds, D. J. Heuscher, and M. Vembar, "Evaluation of spiral CT on a fourth generation system," Eur. J. Radiol. 5, 102-109 (1995).
    • (1995) Eur. J. Radiol. , vol.5 , pp. 102-109
    • Reynolds, M.D.1    Heuscher, D.J.2    Vembar, M.3
  • 7
    • 0018819516 scopus 로고
    • Nonlinear partial volume artifacts in x-ray computed tomography
    • G. H. Glover and N. J. Pelc, "Nonlinear partial volume artifacts in x-ray computed tomography," Med. Phys. 7, 238-248 (1980).
    • (1980) Med. Phys. , vol.7 , pp. 238-248
    • Glover, G.H.1    Pelc, N.J.2
  • 9
    • 33744593973 scopus 로고
    • Partial volume effects: The need to apply correction algorithms for this current limitation in spiral CT
    • D. J. Goodenough, A. Rowberg, and W. Edwards, "Partial volume effects: The need to apply correction algorithms for this current limitation in spiral CT," Radiology 194, 974 (1995).
    • (1995) Radiology , vol.194 , pp. 974
    • Goodenough, D.J.1    Rowberg, A.2    Edwards, W.3
  • 10
    • 33744680554 scopus 로고
    • New algorithm for reducing partial volume artifacts in helical CT
    • Y. Toki, M. Yahata, and Y. Shibata, "New algorithm for reducing partial volume artifacts in helical CT," Radiology 189, 168 (1993).
    • (1993) Radiology , vol.189 , pp. 168
    • Toki, Y.1    Yahata, M.2    Shibata, Y.3
  • 11
    • 0016748032 scopus 로고
    • Potential artifacts associated with the scanning pattern of the EMI scanner
    • D. J. Goodenough, K. E. Weaver, and D. O. Davis, "Potential artifacts associated with the scanning pattern of the EMI scanner," Radiology 117, 615-619 (1975).
    • (1975) Radiology , vol.117 , pp. 615-619
    • Goodenough, D.J.1    Weaver, K.E.2    Davis, D.O.3
  • 12
    • 0017683072 scopus 로고
    • Slice geometry in computer assisted tomography,"
    • A. Brooks and G. Di Chiro, "Slice geometry in computer assisted tomography," J. Comput. Assist. Tomogr. 1, 191-199 (1977).
    • (1977) J. Comput. Assist. Tomogr. , vol.1 , pp. 191-199
    • Brooks, A.1    Chiro, G.D.2
  • 13
    • 0019463118 scopus 로고
    • An improved method for determining CT imaging slice thickness
    • N. Schneiders and S. Bushong, "An improved method for determining CT imaging slice thickness," Med. Phys. 8, 516-519 (1981).
    • (1981) Med. Phys. , vol.8 , pp. 516-519
    • Schneiders, N.1    Bushong, S.2
  • 14
    • 0027955501 scopus 로고
    • Measurement of slice sensitivity profiles in spiral CT
    • A. Polacin, W. A. Kalender, J. Brink, and M. W. Vannier, "Measurement of slice sensitivity profiles in spiral CT," Med. Phys. 21, 133-146 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 133-146
    • Polacin, A.1    Kalender, W.A.2    Brink, J.3    Vannier, M.W.4
  • 15
    • 0027144470 scopus 로고
    • Helical CT image noise - Analytical results
    • G. Wang and M. W. Vannier, "Helical CT image noise - analytical results," Med. Phys. 20, 1635-1640 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1635-1640
    • Wang, G.1    Vannier, M.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.