메뉴 건너뛰기




Volumn 43, Issue 2, 1999, Pages 130-134

Non-invasive evaluation of left ventricular function by means of impedance cardiography

Author keywords

Dobutamine stress echocardiography; Electrical impedance cardiography; Heather index; Left ventricular contractility indicators; Systolic time intervals; Wall motion score

Indexed keywords

DOBUTAMINE;

EID: 0032913029     PISSN: 00015172     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-6576.1999.430203.x     Document Type: Article
Times cited : (16)

References (20)
  • 2
    • 0020522207 scopus 로고
    • Systolic time intervals: A review of the method in the non invasive investigation of cardiac function in health, disease and clinical pharmacology
    • 2. Hassan S, Turner P. Systolic time intervals: a review of the method in the non invasive investigation of cardiac function in health, disease and clinical pharmacology. Postgrad Med J 1983: 59: 423-434.
    • (1983) Postgrad Med J , vol.59 , pp. 423-434
    • Hassan, S.1    Turner, P.2
  • 3
    • 0013523978 scopus 로고
    • A comparison of cardiac output values by the impedance cardiograph and dye dilution techniques in cardiac patients
    • Houston
    • 3. Heather LW. A comparison of cardiac output values by the impedance cardiograph and dye dilution techniques in cardiac patients. Progress Report No. Na 594500. Houston: 1969.
    • (1969) Progress Report No. Na 594500
    • Heather, L.W.1
  • 4
    • 0017810398 scopus 로고
    • The first derivative of the transthoracic electrical impedance as an index of changes in myocardial contractility in the intact anaesthetized dog
    • 4. Welham KC, Mohapatra SN, Hill DW, Stevenson L. The first derivative of the transthoracic electrical impedance as an index of changes in myocardial contractility in the intact anaesthetized dog. Intensive Care Med 1978: 4: 43-50.
    • (1978) Intensive Care Med , vol.4 , pp. 43-50
    • Welham, K.C.1    Mohapatra, S.N.2    Hill, D.W.3    Stevenson, L.4
  • 5
    • 0013522865 scopus 로고
    • Monitoring burn patients at surgery with impedance cardiography and signal averaging microprocessor
    • 5. Marks L, Morris S, McDaniels A, Davies WD. Monitoring burn patients at surgery with impedance cardiography and signal averaging microprocessor. Proc AAMI 14th Ann Meet 1979: 167.
    • (1979) Proc AAMI 14th Ann Meet , vol.167
    • Marks, L.1    Morris, S.2    McDaniels, A.3    Davies, W.D.4
  • 6
    • 0024207333 scopus 로고
    • Detection of impaired left ventricular function in coronary artery disease with acceleration index in the first derivative of the transthoracic impedance change
    • 6. Feng S, Okuda N, Fujinami T, Takada K, Nakano S, Ohte N. Detection of impaired left ventricular function in coronary artery disease with acceleration index in the first derivative of the transthoracic impedance change. Clin Cardiol 1988: 11: 843-847.
    • (1988) Clin Cardiol , vol.11 , pp. 843-847
    • Feng, S.1    Okuda, N.2    Fujinami, T.3    Takada, K.4    Nakano, S.5    Ohte, N.6
  • 8
    • 0028919118 scopus 로고
    • Stress echocardiography. Part II. Dobutamine echocardiography: Techniques, implementations, clinical applications, and correlations
    • 8. Pellika PA, Roger VL, Oh JK, Miller FA, Seward JB, Tajik AJ. Stress echocardiography. Part II. Dobutamine echocardiography: techniques, implementations, clinical applications, and correlations. Mayo Clin Proc 1995: 70: 16-27.
    • (1995) Mayo Clin Proc , vol.70 , pp. 16-27
    • Pellika, P.A.1    Roger, V.L.2    Oh, J.K.3    Miller, F.A.4    Seward, J.B.5    Tajik, A.J.6
  • 9
    • 0027498212 scopus 로고
    • Prognostic value of dobutamine echocardiography in patients with high pretest likelihood of coronary artery disease
    • 9. Mazeika PK, Nadazdin A, Oakley CM. Prognostic value of dobutamine echocardiography in patients with high pretest likelihood of coronary artery disease. Am J Cardiol 1993: 71: 33-39.
    • (1993) Am J Cardiol , vol.71 , pp. 33-39
    • Mazeika, P.K.1    Nadazdin, A.2    Oakley, C.M.3
  • 11
    • 0022979027 scopus 로고
    • Continuous non invasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
    • 11. Bernstein DP. Continuous non invasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit Care Med 1986: 14: 898-901.
    • (1986) Crit Care Med , vol.14 , pp. 898-901
    • Bernstein, D.P.1
  • 13
  • 15
    • 0001952126 scopus 로고
    • Stroke volume equation with a linear base impedance model and its accuracy, as compared to thermodilution and magnetic flowmeter techniques in humans and animals
    • Zadar, Yugoslavia
    • 15. Sramek BB, Rose DM, Miyamoto A. Stroke volume equation with a linear base impedance model and its accuracy, as compared to thermodilution and magnetic flowmeter techniques in humans and animals. Proc 6th Int Conf Electr Bioimpedance, Zadar, Yugoslavia, 1983: 38-41.
    • (1983) Proc 6th Int Conf Electr Bioimpedance , pp. 38-41
    • Sramek, B.B.1    Rose, D.M.2    Miyamoto, A.3
  • 17
    • 0022506229 scopus 로고
    • The use of impedance cardiography in heart failure
    • 17. Hubbard WN, Fish DR, McBrien DJ. The use of impedance cardiography in heart failure. Int J Cardiol 1986: 12: 71-79.
    • (1986) Int J Cardiol , vol.12 , pp. 71-79
    • Hubbard, W.N.1    Fish, D.R.2    McBrien, D.J.3
  • 18
    • 0024504868 scopus 로고
    • Mechano-und impedanzcardiographisches Parameter bei Patienten mit Herzinsufficienz unter Gabe eines Kalziumantagonisten. Die bedeutung des Heather-Index
    • 18. Linde M, Ohnhaus E, Kirch W. Mechano-und impedanzcardiographisches Parameter bei Patienten mit Herzinsufficienz unter Gabe eines Kalziumantagonisten. Die bedeutung des Heather-Index. Z Kardiol 1989: 78: 181-186.
    • (1989) Z Kardiol , vol.78 , pp. 181-186
    • Linde, M.1    Ohnhaus, E.2    Kirch, W.3
  • 19
    • 0026729882 scopus 로고
    • Relative sensitivity of four non invasive methods in assesssing systolic cardiovascular effects of isoproterenol in healthy volunteers
    • 19. De Mey C, Belz GG, Nixdorf U, Butzer R, Schroeter V, Meyer J et al. Relative sensitivity of four non invasive methods in assesssing systolic cardiovascular effects of isoproterenol in healthy volunteers. Clin Pharmacol Ther 1992: 52: 609-619.
    • (1992) Clin Pharmacol Ther , vol.52 , pp. 609-619
    • De Mey, C.1    Belz, G.G.2    Nixdorf, U.3    Butzer, R.4    Schroeter, V.5    Meyer, J.6
  • 20
    • 0030899091 scopus 로고    scopus 로고
    • Continuous measurement of hemodynamic alterations during pharmacologic stress using automated impedance cardiography
    • 20. Scherhag AW, Pfleger S, de Mey C, Schreckenberger AB, Staedt U, Heene DL. Continuous measurement of hemodynamic alterations during pharmacologic stress using automated impedance cardiography. J Clin Pharmacol 1997: 37: 21S-28S.
    • (1997) J Clin Pharmacol , vol.37
    • Scherhag, A.W.1    Pfleger, S.2    De Mey, C.3    Schreckenberger, A.B.4    Staedt, U.5    Heene, D.L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.