메뉴 건너뛰기




Volumn 41, Issue 1, 1999, Pages 171-178

Locally focused 3D coronary imaging using volume-selective RF excitation

Author keywords

2D RF excitation; 3D coronary angiography; Echoplanar imaging; Image reconstruction; Respiratory motion

Indexed keywords

ANGIOCARDIOGRAPHY; BIOMEDICAL SIGNAL PROCESSING; ENCODING (SYMBOLS); HEART; IMAGE ENHANCEMENT; MAGNETIC RESONANCE; RESPIRATORY MECHANICS; SIGNAL TO NOISE RATIO;

EID: 0032904378     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199901)41:1<171::AID-MRM24>3.0.CO;2-5     Document Type: Article
Times cited : (20)

References (8)
  • 3
    • 0026955085 scopus 로고
    • MR imaging was spatially variable resolution
    • Cao Y, Levin DN. MR imaging was spatially variable resolution. J Magn Reson Imaging 1992;2:701-709.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 701-709
    • Cao, Y.1    Levin, D.N.2
  • 4
    • 0029856450 scopus 로고    scopus 로고
    • 2D locally focused MRI: Applications to dynamic and spectroscopic imaging
    • Yao L, Cao Y, Levin DN. 2D locally focused MRI: applications to dynamic and spectroscopic imaging. Magn Reson Med 1996;36:834-846.
    • (1996) Magn Reson Med , vol.36 , pp. 834-846
    • Yao, L.1    Cao, Y.2    Levin, D.N.3
  • 5
    • 0029276838 scopus 로고
    • Selection of observations in signal reconstruction
    • Reeves SJ, Heck LP. Selection of observations in signal reconstruction. IEEE Trans Signal Processing 1995;43:788-791.
    • (1995) IEEE Trans Signal Processing , vol.43 , pp. 788-791
    • Reeves, S.J.1    Heck, L.P.2
  • 6
    • 0029266251 scopus 로고
    • Selection of k-space samples in localized MR spectroscopy of arbitrary volumes of interest
    • Reeves SJ. Selection of k-space samples in localized MR spectroscopy of arbitrary volumes of interest. J Magn Reson Imaging 1995;5:245-247.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 245-247
    • Reeves, S.J.1
  • 7
    • 0030739762 scopus 로고    scopus 로고
    • Motion-adapted gating based on k-space weighting for reduction of respiratory motion artifacts
    • Weiger M, Börnert P, Proksa R, Schäffter T, Haase A. Motion-adapted gating based on k-space weighting for reduction of respiratory motion artifacts. Magn Reson Med 1997;38:322-333.
    • (1997) Magn Reson Med , vol.38 , pp. 322-333
    • Weiger, M.1    Börnert, P.2    Proksa, R.3    Schäffter, T.4    Haase, A.5
  • 8
    • 0024131143 scopus 로고
    • The information content of MR images
    • Fuderer M. The information content of MR images. IEEE Trans Med Imaging 1988;7:368-380.
    • (1988) IEEE Trans Med Imaging , vol.7 , pp. 368-380
    • Fuderer, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.