메뉴 건너뛰기




Volumn 80, Issue 5, 1999, Pages 495-500

Multicenter evaluation of electrical stimulation systems for walking

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; ELECTROSTIMULATION THERAPY; FEEDBACK SYSTEM; GAIT DISORDER; HEAD INJURY; HUMAN; MULTICENTER STUDY; MUSCLE WEAKNESS; NEUROLOGIC DISEASE; QUADRICEPS FEMORIS MUSCLE; SPINAL CORD INJURY; STROKE; TREATMENT OUTCOME; WALKING SPEED;

EID: 0032898535     PISSN: 00039993     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-9993(99)90188-0     Document Type: Article
Times cited : (115)

References (22)
  • 1
    • 73049136842 scopus 로고
    • Functional electrotherapy, stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients
    • Liberson WT, Holmquest HJ, Scott D, Dow M. Functional electrotherapy, stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch Phys Med 1961;42:101-5.
    • (1961) Arch Phys Med , vol.42 , pp. 101-105
    • Liberson, W.T.1    Holmquest, H.J.2    Scott, D.3    Dow, M.4
  • 2
    • 0026607441 scopus 로고
    • Neural prostheses: Clinical applications of functional electrical stimulation in spinal cord injury
    • Peckham PH, Creasey GH. Neural prostheses: clinical applications of functional electrical stimulation in spinal cord injury. Paraplegia 1992;30:96-101.
    • (1992) Paraplegia , vol.30 , pp. 96-101
    • Peckham, P.H.1    Creasey, G.H.2
  • 3
    • 0018676840 scopus 로고
    • Clinical experience of electronic peroneal stimulators in 50 hemiparetic patients
    • Merletti R, Andina A, Galante M, Furlan I. Clinical experience of electronic peroneal stimulators in 50 hemiparetic patients. Scand J Rehabil Med 1979:11:111-21.
    • (1979) Scand J Rehabil Med , vol.11 , pp. 111-121
    • Merletti, R.1    Andina, A.2    Galante, M.3    Furlan, I.4
  • 4
    • 0027484389 scopus 로고
    • Enhancement of hemiplegic patient rehabilitation by means of functional electrical stimulation
    • Kralj A, Ačimović R, Stanić U. Enhancement of hemiplegic patient rehabilitation by means of functional electrical stimulation. Prosth Orthot Int 1993;17:107-14.
    • (1993) Prosth Orthot Int , vol.17 , pp. 107-114
    • Kralj, A.1    Ačimović, R.2    Stanić, U.3
  • 7
    • 0022749698 scopus 로고
    • Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities
    • Marsolais EB, Kobetic R. Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities. J Rehabil Res Dev 1986;23:1-8.
    • (1986) J Rehabil Res Dev , vol.23 , pp. 1-8
    • Marsolais, E.B.1    Kobetic, R.2
  • 9
    • 1842413032 scopus 로고    scopus 로고
    • Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II). Part I: Performance evaluation of 70 paraplegic patients
    • Solomonow M, Aguilar E, Reisin E, Baratta RV, Best R, Coetzee T, et al. Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II). Part I: performance evaluation of 70 paraplegic patients. Orthopedics 1997;20:315-24.
    • (1997) Orthopedics , vol.20 , pp. 315-324
    • Solomonow, M.1    Aguilar, E.2    Reisin, E.3    Baratta, R.V.4    Best, R.5    Coetzee, T.6
  • 10
    • 0025029883 scopus 로고
    • Energy consumption in paraplegic ambulation using the reciprocating gait orthosis and electrical stimulation of thigh muscles
    • Hirokawa S, Grimm M, Le T, Solomonow M, Baratta RV, Shoji H, et al. Energy consumption in paraplegic ambulation using the reciprocating gait orthosis and electrical stimulation of thigh muscles. Arch Phys Med Rehabil 1990;71:687-94.
    • (1990) Arch Phys Med Rehabil , vol.71 , pp. 687-694
    • Hirokawa, S.1    Grimm, M.2    Le, T.3    Solomonow, M.4    Baratta, R.V.5    Shoji, H.6
  • 11
    • 0025103314 scopus 로고
    • Energy cost of paraplegic locomotion using the para Walker electrical stimulation "hybrid" orthosis
    • Nene AV, Patrick JH. Energy cost of paraplegic locomotion using the Para Walker electrical stimulation "hybrid" orthosis. Arch Phys Med Rehabil 1990;71:116-20.
    • (1990) Arch Phys Med Rehabil , vol.71 , pp. 116-120
    • Nene, A.V.1    Patrick, J.H.2
  • 12
    • 0026063051 scopus 로고
    • Physiologic costs of computer-controlled walking in persons with paraplegia using a reciprocating-gait orthosis
    • Petrofsky JS, Smith JB. Physiologic costs of computer-controlled walking in persons with paraplegia using a reciprocating-gait orthosis. Arch Phys Med Rehabil 1991;72:890-96.
    • (1991) Arch Phys Med Rehabil , vol.72 , pp. 890-896
    • Petrofsky, J.S.1    Smith, J.B.2
  • 13
    • 0021925358 scopus 로고
    • Restoration of walking in patients with incomplete spinal cord injuries by use of surface electrical stimulation
    • Bajd T, Andrews BJ, Kralj A, Katakis J. Restoration of walking in patients with incomplete spinal cord injuries by use of surface electrical stimulation. Prosthet Orthot Int 1985;9:109-11.
    • (1985) Prosthet Orthot Int , vol.9 , pp. 109-111
    • Bajd, T.1    Andrews, B.J.2    Kralj, A.3    Katakis, J.4
  • 14
    • 0027199261 scopus 로고
    • The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury - Observed benefits during gait studies
    • Granat MH, Ferguson AC, Andrews BJ, Delargy M. The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury - observed benefits during gait studies. Paraplegia 1993;31:207-15.
    • (1993) Paraplegia , vol.31 , pp. 207-215
    • Granat, M.H.1    Ferguson, A.C.2    Andrews, B.J.3    Delargy, M.4
  • 21
    • 0023898102 scopus 로고
    • Biofeedback and functional electric stimulation in stroke rehabilitation
    • Cozean CD, Pease WS, Hubbell SL. Biofeedback and functional electric stimulation in stroke rehabilitation. Arch Phys Med Rehabil 1986;69:401-5.
    • (1986) Arch Phys Med Rehabil , vol.69 , pp. 401-405
    • Cozean, C.D.1    Pease, W.S.2    Hubbell, S.L.3
  • 22
    • 85030352241 scopus 로고    scopus 로고
    • Commercialization of an FES device
    • Aug; Vancouver, Canada
    • Gibson W. Commercialization of an FES device [abstract]. In: 2nd International FES Society Proceedings; 1997 Aug; Vancouver, Canada. p. 205.
    • (1997) 2nd International FES Society Proceedings , pp. 205
    • Gibson, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.