메뉴 건너뛰기




Volumn 72, Issue APR., 1999, Pages 384-388

Value of a multileaf prescription preparation system for palliative external beam irradiation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BODY SURFACE; BONE METASTASIS; CENTRAL NERVOUS SYSTEM; COLLIMATOR; COMPARATIVE STUDY; COMPUTER PROGRAM; DEVICE; HUMAN; HUMAN TISSUE; INFORMATION PROCESSING DEVICE; LIMB; LYMPH NODE; MAJOR CLINICAL STUDY; PALLIATIVE THERAPY; PELVIS; RADIATION INJURY; RADIATION SHIELD; RADIOTHERAPY; SIMULATION; SOFT TISSUE; SPINE; STATISTICAL ANALYSIS; TIME; TREATMENT PLANNING;

EID: 0032895734     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr.72.856.10474500     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 0006829854 scopus 로고
    • Radiation therapy in palliative cancer management
    • Perez CA, Brady LW, editors. Philadelphia, PA: Lippincott Co.
    • Karga AR. Radiation therapy in palliative cancer management. In: Perez CA, Brady LW, editors. Principles and practice of radiation oncology (2nd edn). Philadelphia, PA: Lippincott Co., 1992: 1495 1507.
    • (1992) Principles and Practice of Radiation Oncology (2nd Edn) , pp. 1495-1507
    • Karga, A.R.1
  • 2
    • 0023915469 scopus 로고
    • Optimal setting of multileaf collimators in stationary beam radiation therapy
    • Brahme A. Optimal setting of multileaf collimators in stationary beam radiation therapy. Strahlenther Onkol 1988;164:343-50.
    • (1988) Strahlenther Onkol , vol.164 , pp. 343-350
    • Brahme, A.1
  • 3
    • 0016246036 scopus 로고
    • Computer calculations of dose for irregularly shaped fields for Co60 and 6 MV photons
    • Bukowitz AG. Computer calculations of dose for irregularly shaped fields for Co60 and 6 MV photons. Radiology 1974;113:181-5.
    • (1974) Radiology , vol.113 , pp. 181-185
    • Bukowitz, A.G.1
  • 4
    • 0014524568 scopus 로고
    • Irregular field shaping for Co-60 teletherapy
    • Edland RW, Hansen H. Irregular field shaping for Co-60 teletherapy. Radiology 1969;92:1579-83.
    • (1969) Radiology , vol.92 , pp. 1579-1583
    • Edland, R.W.1    Hansen, H.2
  • 6
    • 0028788683 scopus 로고
    • Multileaf collimation versus conventional shielding blocks: A time and motion study of beam shaping in radiotherapy
    • Helyer SJ, Heisig S. Multileaf collimation versus conventional shielding blocks: a time and motion study of beam shaping in radiotherapy. Radiother Oncol 1995;37:61-4.
    • (1995) Radiother Oncol , vol.37 , pp. 61-64
    • Helyer, S.J.1    Heisig, S.2
  • 7
    • 0026591457 scopus 로고
    • Computer-assisted generation of multileaf collimator settings for conformation therapy
    • Hounsell AR, Sharrock PJ, Moore CJ. Computer-assisted generation of multileaf collimator settings for conformation therapy. Br J Radiol 1992;65: 321-6.
    • (1992) Br J Radiol , vol.65 , pp. 321-326
    • Hounsell, A.R.1    Sharrock, P.J.2    Moore, C.J.3
  • 8
    • 0028346915 scopus 로고
    • The design and performance characteristics of a multileaf collimator
    • Jordan TJ, Williams PC. The design and performance characteristics of a multileaf collimator. Phys Med Biol 1994;39:231-51.
    • (1994) Phys Med Biol , vol.39 , pp. 231-251
    • Jordan, T.J.1    Williams, P.C.2
  • 9
    • 0029065603 scopus 로고
    • Multileaf collimation versus cerrobend blocks: Analysis of geometry and accuracy
    • LaSasso T, Kutcher GJ. Multileaf collimation versus cerrobend blocks: analysis of geometry and accuracy. Int J Radiat Oncol Biol Phys 1995;32:499-506.
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 499-506
    • LaSasso, T.1    Kutcher, G.J.2
  • 10
    • 0026918287 scopus 로고
    • Weight considerations in the use of cerrobend beam blocks
    • Rieger J, Mehta M, Paliwal B, Kubsad S. Weight considerations in the use of cerrobend beam blocks. Med Dosim 1992;17:141-3.
    • (1992) Med Dosim , vol.17 , pp. 141-143
    • Rieger, J.1    Mehta, M.2    Paliwal, B.3    Kubsad, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.