메뉴 건너뛰기




Volumn 30, Issue 1, 1999, Pages 69-71

The use of rectus abdominis sheath for wrapping of the hydroxyapatite orbital implants

Author keywords

[No Author keywords available]

Indexed keywords

HYDROXYAPATITE;

EID: 0032894839     PISSN: 10823069     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (37)

References (7)
  • 1
    • 0028890018 scopus 로고
    • Coralline hydroxyapatite spheres as secondary orbital implants in anophthalmos
    • Massry GG, Hold JB. Coralline hydroxyapatite spheres as secondary orbital implants in anophthalmos. Ophthalmology. 1995;102:161-166.
    • (1995) Ophthalmology , vol.102 , pp. 161-166
    • Massry, G.G.1    Hold, J.B.2
  • 2
    • 0025976934 scopus 로고
    • Coastline hydroxyapatite as an ocular implant
    • Duton JJ. Coastline hydroxyapatite as an ocular implant. Ophthalmology. 1991;98:370-377.
    • (1991) Ophthalmology , vol.98 , pp. 370-377
    • Duton, J.J.1
  • 3
    • 0026651109 scopus 로고
    • Tissue breakdown and exposure associated with orbital hydroxyapatite implants
    • Buottner H, Barney GB. Tissue breakdown and exposure associated with orbital hydroxyapatite implants. Am J Ophthalmol. 1992;113:669-673.
    • (1992) Am J Ophthalmol , vol.113 , pp. 669-673
    • Buottner, H.1    Barney, G.B.2
  • 4
    • 0027235625 scopus 로고
    • Exposure rate of hydroxyapatite spheres in the anophthalmic socket: Histologic correlation and comparison with silicone sphere implants
    • Nunery WR, Heinz GW, Bonnin JM, Martin RT, Cepela MA. Exposure rate of hydroxyapatite spheres in the anophthalmic socket: histologic correlation and comparison with silicone sphere implants. Ophthal Plast Reconstr Surg. 1993;9:96-104.
    • (1993) Ophthal Plast Reconstr Surg , vol.9 , pp. 96-104
    • Nunery, W.R.1    Heinz, G.W.2    Bonnin, J.M.3    Martin, R.T.4    Cepela, M.A.5
  • 5
    • 0029016072 scopus 로고
    • The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants
    • Jordan DR, Alien LH, Ells A, et al. The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants. Ophthal Plast Reconstr Surg. 1995;11:95-99.
    • (1995) Ophthal Plast Reconstr Surg , vol.11 , pp. 95-99
    • Jordan, D.R.1    Alien, L.H.2    Ells, A.3
  • 6
    • 0026093148 scopus 로고
    • Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant
    • Shields CL, Shields JA, Eagle RC, Potter PD. Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant. Am J Ophthalmol. 1991;111:363-366.
    • (1991) Am J Ophthalmol , vol.111 , pp. 363-366
    • Shields, C.L.1    Shields, J.A.2    Eagle, R.C.3    Potter, P.D.4
  • 7
    • 0031018705 scopus 로고    scopus 로고
    • Complications of hydroxyapatite orbital implants. A review of 100 consecutive cases and a comparison of Dexon mesh (poly-glycolic acid) with scleral wrapping
    • Oestreicher JH, Lin E, Berkowitz M. Complications of hydroxyapatite orbital implants. A Review of 100 consecutive cases and a comparison of Dexon mesh (poly-glycolic acid) with scleral wrapping. Ophthalmology. 1997;104:324-329.
    • (1997) Ophthalmology , vol.104 , pp. 324-329
    • Oestreicher, J.H.1    Lin, E.2    Berkowitz, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.