-
1
-
-
0017713192
-
Prospective study of the Robertshaw endobronchial catheter in thoracic surgery
-
Read RC, Friday CD, Eason CN. Prospective study of the Robertshaw endobronchial catheter in thoracic surgery. Ann Thorac Surg 1977; 24: 156-61.
-
(1977)
Ann Thorac Surg
, vol.24
, pp. 156-161
-
-
Read, R.C.1
Friday, C.D.2
Eason, C.N.3
-
3
-
-
85088326095
-
Techniques using the Bullard laryngoscope
-
Crosby ET. Techniques using the Bullard laryngoscope (Letter). Anesth Analg 1995; 81: 1311-20.
-
(1995)
Anesth Analg
, vol.81
, pp. 1311-1320
-
-
Crosby, E.T.1
-
4
-
-
17544391230
-
Forced air warming can facilitate fiberoptic intubations
-
Dunn SM, Pulai I. Forced air warming can facilitate fiberoptic intubations (Letter). Anesthesiology 1998; 88: 282.
-
(1998)
Anesthesiology
, vol.88
, pp. 282
-
-
Dunn, S.M.1
Pulai, I.2
-
5
-
-
0021701206
-
Difficult tracheal intubation in obstetrics
-
Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11.
-
(1984)
Anaesthesia
, vol.39
, pp. 1105-1111
-
-
Cormack, R.S.1
Lehane, J.2
-
6
-
-
0028847105
-
Awake endotracheal intubation in patients with cervical spine disease: A comparison of the Bullard laryngoscope and the fiberoptic broncho-scope
-
Cohn AI, Zornow MH. Awake endotracheal intubation in patients with cervical spine disease: a comparison of the Bullard laryngoscope and the fiberoptic broncho-scope. Anesth Analg 1995; 81: 1283-6.
-
(1995)
Anesth Analg
, vol.81
, pp. 1283-1286
-
-
Cohn, A.I.1
Zornow, M.H.2
-
7
-
-
0028104556
-
Evaluation of the bullard laryngoscope using the new intubating stylet: Comparison with conventional laryngoscopy
-
Cooper SD, Benumof JL, Ozaki GT. Evaluation of the Bullard laryngoscope using the new intubating stylet: comparison with conventional laryngoscopy. Anesth Analg 1994; 79: 965-70.
-
(1994)
Anesth Analg
, vol.79
, pp. 965-970
-
-
Cooper, S.D.1
Benumof, J.L.2
Ozaki, G.T.3
-
8
-
-
0031454801
-
Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury
-
Watts ADJ, Gelb AW, Bach DB, Pelz DM. Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury. Anesthesiology 1997; 87: 1335-42.
-
(1997)
Anesthesiology
, vol.87
, pp. 1335-1342
-
-
Watts, A.D.J.1
Gelb, A.W.2
Bach, D.B.3
Pelz, D.M.4
-
9
-
-
0028916427
-
Cervical spine movement during laryngoscopy with the Bullard, Macintosh and Miller laryngoscopes
-
Hastings RH, Vigil AC, Hanna R, Yang B-Y, Sartoris DJ. Cervical spine movement during laryngoscopy with the Bullard, Macintosh and Miller laryngoscopes. Anesthesiology 1995; 82: 859-69.
-
(1995)
Anesthesiology
, vol.82
, pp. 859-869
-
-
Hastings, R.H.1
Vigil, A.C.2
Hanna, R.3
Yang, B.-Y.4
Sartoris, D.J.5
-
10
-
-
2642634792
-
The adult Bullard laryngoscope in paediatric patients
-
Shulman GB, Connelly NR, Gibson C. The adult Bullard laryngoscope in paediatric patients. Can J Anaesth 1997; 44: 969-72.
-
(1997)
Can J Anaesth
, vol.44
, pp. 969-972
-
-
Shulman, G.B.1
Connelly, N.R.2
Gibson, C.3
-
11
-
-
0025058913
-
The Bullard laryngoscope. A new indirect oral laryngoscope (pediatric version)
-
Borland LM, Casselbrant M. The Bullard laryngoscope. A new indirect oral laryngoscope (pediatric version). Anesth Analg 1990; 70: 105-8.
-
(1990)
Anesth Analg
, vol.70
, pp. 105-108
-
-
Borland, L.M.1
Casselbrant, M.2
-
12
-
-
0028020942
-
Improvement of the left broncho-cath double-lumen tube
-
Virag RA, Yahagi N, Furuya H, et al. Improvement of the left broncho-cath double-lumen tube (Letter). Anesthesiology 1994: 81: 781-2.
-
(1994)
Anesthesiology
, vol.81
, pp. 781-782
-
-
Virag, R.A.1
Yahagi, N.2
Furuya, H.3
-
13
-
-
0031913886
-
Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia
-
Klein U, Karzai W, Bloos F, et al. Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia. Anesthesiology 1998; 88: 346-50.
-
(1998)
Anesthesiology
, vol.88
, pp. 346-350
-
-
Klein, U.1
Karzai, W.2
Bloos, F.3
|