메뉴 건너뛰기




Volumn 38, Issue 6, 1999, Pages 192-198

Quantification of repositioning errors in PET-studies through superposition of emission and transmission scan: A comparison between one- step and two-step acquisitions;Quantifizierung von repositionierungsfehlern bei PET-studien durch uberlagerung von emissions- und transmissionsscan: Ein vergleich zwischen akquisitionen mit und ohne repositionierung

Author keywords

Artifact; Image fusion; Overlay; PET; Quality control; Repositioning

Indexed keywords

ANALYTICAL ERROR; ARTICLE; ARTIFACT; HUMAN; IMAGE DISPLAY; PHANTOM; POSITRON EMISSION TOMOGRAPHY; WHOLE BODY SCINTISCANNING;

EID: 0032885255     PISSN: 00295566     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-0038-1632218     Document Type: Article
Times cited : (5)

References (17)
  • 2
    • 0031847790 scopus 로고    scopus 로고
    • Transmission scanning in emission tomography
    • Bailey DL. Transmission scanning in emission tomography. Eur J Nucl Med 1998; 25: 774-87.
    • (1998) Eur J Nucl Med , vol.25 , pp. 774-787
    • Bailey, D.L.1
  • 3
    • 0031722183 scopus 로고    scopus 로고
    • Cardiac positron emission tomography
    • Bergmann SR. Cardiac positron emission tomography. Semin Nucl Med 1998; 28: 320-40.
    • (1998) Semin Nucl Med , vol.28 , pp. 320-340
    • Bergmann, S.R.1
  • 4
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • Bergstrom M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Comput Assist Tomogr 1983; 7: 42-50.
    • (1983) J Comput Assist Tomogr , vol.7 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 5
    • 0031851405 scopus 로고    scopus 로고
    • PET instrumentation: What are the limits?
    • Budinger TF. PET instrumentation: what are the limits? Semin Nucl Med 1998; 28: 247-67.
    • (1998) Semin Nucl Med , vol.28 , pp. 247-267
    • Budinger, T.F.1
  • 6
    • 0018367149 scopus 로고
    • Quantitation in positron emission computed tomography: Effect of object size
    • Hoffmann EJ, Sung-Cheng H, Phelps ME. Quantitation in positron emission computed tomography: Effect of object size. J Comput Assist Tomogr 1979; 3: 299-308.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 299-308
    • Hoffmann, E.J.1    Sung-Cheng, H.2    Phelps, M.E.3
  • 7
    • 0028242162 scopus 로고
    • A method of correlating and merging cerebral morphology and function by a special head holder
    • Kaiser HJ, Sabri O, Wagenknecht G, Lege B, Hellwig D, Büll U. A method of correlating and merging cerebral morphology and function by a special head holder. Nuklearmedizin 1994; 33: 123-6.
    • (1994) Nuklearmedizin , vol.33 , pp. 123-126
    • Kaiser, H.J.1    Sabri, O.2    Wagenknecht, G.3    Lege, B.4    Hellwig, D.5    Büll, U.6
  • 12
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for positron emission tomography
    • Shepp LA, Vardi Y. Maximum likelihood reconstruction for positron emission tomography. IEEE Trans Med Imaging 1982; 2: 113-22.
    • (1982) IEEE Trans Med Imaging , vol.2 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 17
    • 85056014857 scopus 로고    scopus 로고
    • Einfluß von schwächungskorrektur und rekonstruktionsverfahren auf abbildungseigenschaften von herdbefunden bei Onko-PET
    • Zimny M, Reinartz P, Cremerius U, Kaiser HJ, Büll U. Einfluß von Schwächungskorrektur und Rekonstruktionsverfahren auf Abbildungseigenschaften von Herdbefunden bei Onko-PET. Nuklearmedizin 1998; 37: V13.
    • (1998) Nuklearmedizin , vol.37
    • Zimny, M.1    Reinartz, P.2    Cremerius, U.3    Kaiser, H.J.4    Büll, U.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.